Design of the "half-size" ITER neutral beam source for the test facility ELISE

被引:119
作者
Heinemann, B. [1 ]
Falter, H. [1 ]
Fantza, U. [1 ]
Franzen, R. [1 ]
Froeschle, M. [1 ]
Gutser, R. [1 ]
Kraus, W. [1 ]
Nocentini, R. [1 ]
Riedl, R. [1 ]
Speth, E. [1 ]
Staebler, A. [1 ]
Wuenderlich, D. [1 ]
Agostinetti, P. [2 ]
Jiang, T. [3 ]
机构
[1] EURATOM, Max Planck Inst Plasmaphys, D-85740 Garching, Germany
[2] EURATOM, Consorzio RFX, I-35127 Padua, Italy
[3] SW Inst Phys, Chengdu, Peoples R China
关键词
Neutral beam heating systems; Negative ion source; Radio frequency ion source; ITER;
D O I
10.1016/j.fusengdes.2008.11.076
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In 2007 the radio frequency driven negative hydrogen ion source developed at IPP in Garching was chosen by the ITER board as the new reference source for the ITER neutral beam system. In order to support the design and the commissioning and operating phases of the ITER test facilities ISTF and NBTF in Padua, IPP is presently constructing a new test facility ELISE (Extraction from a Large Ion Source Experiment). ELISE will be operated with the so-called "half-size iTER source" which is an intermediate step between the present small IPP RF sources (1/8 ITER size) and the full size ITER source. The source will have approximately the width but only half the height of the ITER source. The modular concept with 4 drivers will allow an easy extrapolation to the full ITER size with 8 drivers. Pulsed beam extraction and acceleration up to 60 W (corresponding to pre-acceleration voltage of SINGAP) is foreseen. The aim of the design of the ELISE source and extraction system was to be as close as possible to the ITER design; it has however some modifications allowing a better diagnostic access as well as more flexibility for exploring open questions. Therefore one major difference compared to the source of ITER, NBTF or ISTF is the possible operation in air. Specific requirements for RF sources as found on IPP test facilities BATMAN and MANITU are implemented [A. Stabler, et al., Development of a RF-driven ion source for the ITER NBI system, SOFT Conference 2008, Fusion Engineering and Design, 84 (2009) 265-268]. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:915 / 922
页数:8
相关论文
共 12 条
[1]  
de Esch H.P.L, COMMUNICATION
[2]   Updated physics design ITER-SINGAP accelerator [J].
de Esch, HPL ;
Hemsworth, RS ;
Massmann, P .
FUSION ENGINEERING AND DESIGN, 2005, 73 (2-4) :329-341
[3]   NEUTRAL BEAM INJECTION SYSTEM [J].
DUESING, G ;
ALTMANN, H ;
FALTER, H ;
GOEDE, A ;
HAANGE, R ;
HEMSWORTH, RS ;
KUPSCHUS, P ;
STORK, D ;
THOMPSON, E .
FUSION TECHNOLOGY, 1987, 11 (01) :163-202
[4]   Progress of the development of the IPP RF negative ion source for the ITER neutral beam system [J].
Franzen, P. ;
Falter, H. D. ;
Fantz, U. ;
Kraus, W. ;
Berger, M. ;
Christ-Koch, S. ;
Froeschle, M. ;
Gutser, R. ;
Heinemann, B. ;
Hilbert, S. ;
Leyer, S. ;
Martens, C. ;
McNeely, P. ;
Riedl, R. ;
Speth, E. ;
Wuenderlich, D. .
NUCLEAR FUSION, 2007, 47 (04) :264-270
[5]  
FRANZEN P, 2008, P 1 INT C NEG IONS B
[6]   Modeling of secondary emission processes in the negative ion based electrostatic accelerator of the International Thermonuclear Experimental Reactor [J].
Fubiani, G. ;
de Esch, H. P. L. ;
Simonin, A. ;
Hemsworth, R. S. .
PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2008, 11 (01)
[7]  
GUTSER R, 2008, P 1 INT C NEG IONS B
[8]   Long pulse large area beam extraction with a rf driven H-/D- source [J].
Kraus, W. ;
Falter, H. -D. ;
Fantz, U. ;
Franzen, P. ;
Heinemann, B. ;
McNeely, P. ;
Riedl, R. ;
Speth, E. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02)
[9]  
Kraus W., 2008, P 35 EPS C JUN
[10]  
Nocentini R., FUSION ENG IN PRESS