Application of Digital Image Processing to Detect Transformer Bushing Faults and Oil Degradation using FRA Polar Plot Signature

被引:51
作者
Aljohani, O. [1 ]
Abu-Siada, A. [1 ]
机构
[1] Curtin Univ, Dept Elect & Comp Engn, Perth, WA 6102, Australia
关键词
Power transformer; condition monitoring; frequency response analysis; digital image processing; bushing faults; insulating oil degradation; FREQUENCY-RESPONSE; TEMPERATURE; DIAGNOSTICS; INSULATION; MOISTURE;
D O I
10.1109/TDEI.2016.006088
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency Response Analysis (FRA) technique is commonly used to assess the mechanical integrity of power transformer core and windings. A few papers investigating the ability of FRA technique to detect bushing faults and transformer oil degradation can be found in the literatures. However, in all of these papers, only magnitude of the FRA signature along with visual analysis was used for fault identification and quantification which may lead to inconsistent conclusions for the same FRA signature when interpreted by various personnel. As such, there is an essential need to standardize and automate the FRA interpretation process to improve its reliability and accuracy. This paper is taking a step forward toward this goal through presenting a new FRA interpretation approach by incorporating the magnitude and phase angle plots of the measured FRA signature into one polar plot that comprises more features than the conventional magnitude plot currently used for fault diagnosis. Moreover, the proposed polar plot facilitates the application of digital image processing techniques ( DIP) to automate and standardize the whole process. The new proposed technique is assessed through its application to detect minor transformer bushing faults and insulating oil degradations. In this regard, two transformers of different ratings, winding structure and physical dimensions are simulated using 3D finite element analysis to implement various levels of transformer bushing faults and oil degradation. The obtained FRA polar plots of the two investigated transformers under various bushings and oil health conditions are manipulated using the developed DIP codes to investigate the impact of each fault type / level on the proposed polar plot signature. Also, Practical measurements are performed to validate simulation results and evaluate the feasibility of the proposed technique. Results show the ability of the proposed technique to automate the detection of minor levels of bushing faults and insulating oil degradation with a high degree of accuracy.
引用
收藏
页码:428 / 436
页数:9
相关论文
共 38 条
[2]   A Novel Online Technique to Detect Power Transformer Winding Faults [J].
Abu-Siada, A. ;
Islam, Syed .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (02) :849-857
[3]   Experimental Verification and Finite Element Analysis of Short-Circuit Electromagnetic Force for Dry-Type Transformer [J].
Ahn, Hyun-Mo ;
Oh, Yeon-Ho ;
Kim, Joong-Kyoung ;
Song, Jae-Sung ;
Hahn, Sung-Chin .
IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (02) :819-822
[4]  
Aljohani O., 2015, POW ENG C AUPEC 2015, P1
[5]  
Aljohani O., 2014, PES GEN M C EXP 2014, P1
[6]   A logarithmic-amplitude polar diagram [J].
Andresen, T .
MODELING IDENTIFICATION AND CONTROL, 2001, 22 (02) :65-72
[7]  
[Anonymous], 2012, MICCAI WORKSH PAED P
[8]   Modelling the Dielectric Response Measurements of Transformer oil [J].
Bandara, Kapila ;
Ekanayake, Chandima ;
Saha, Tapan Kumar .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) :1283-1291
[9]  
Bao W, 2009, PROCEEDINGS OF 2009 IEEE INTERNATIONAL CONFERENCE ON SERVICE OPERATION, LOGISTICS AND INFORMATICS, P497, DOI 10.1109/SOLI.2009.5203984
[10]  
Bertrand Y., 2007, VEGETABLE OILS SUBST, V24