Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams

被引:9
作者
Gimenez-Alventosa, Vicent [1 ]
Gimenez, Vicente [2 ,3 ]
Ballester, Facundo [4 ,5 ]
Vijande, Javier [3 ,4 ,5 ]
Andreo, Pedro [6 ]
机构
[1] Univ Politecn Valencia, CSIC, Ctr Mixto, Inst Instrumentac Imagen Mol I3M, Valencia, Spain
[2] Univ Valencia, Dept Theoret Phys, Burjassot, Spain
[3] UV, CSIC, IFIC, Inst Fis Corpuscular, Paterna, Spain
[4] Univ Valencia, Dept Atom Mol & Nucl Phys, Burjassot, Spain
[5] UV, IIS La Fe, IRIMED Joint Res Unit, Valencia, Spain
[6] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
关键词
TRS; 398; Monte Carlo; dosimetry; ionization chambers; MV photon beams; ENERGY; PENELOPE; SIMULATION; TRANSPORT; ALGORITHM;
D O I
10.1088/1361-6560/ab9501
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The beam quality correction factork(Q)for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of the International Code of Practice for dosimetry based on standards of absorbed dose to water (IAEA TRS 398). The values reported in this work agree with those in the literature within the uncertainty estimates and are to be included in the average values of the data obtained by different working groups for the forthcoming update of TRS 398.
引用
收藏
页数:11
相关论文
共 39 条
[1]   DESIGN OF A THIMBLE CHAMBER FOR FARMER DOSIMETER [J].
AIRD, EGA ;
FARMER, FT .
PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (02) :169-&
[2]  
Almond P, 1997, IAEA TECHNICAL REPOR, V381
[3]  
Andreo P., 2000, IAEA TECHNICAL REPOR, V398
[4]  
Andreo P, 1987, IAEA TECHNICAL REPOR, V277
[5]  
Andreo P, 2019, BOOK EXTENDED SYNOPS, P71
[6]   Consistency in reference radiotherapy dosimetry: resolution of an apparent conundrum when 60Co is the reference quality for charged-particle and photon beams [J].
Andreo, Pedro ;
Wulff, Joerg ;
Burns, David T. ;
Palmans, Hugo .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19) :6593-6621
[7]  
[Anonymous], 1973, THEORETICAL PHOTOION
[8]   PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[9]   X-RAY WAVELENGTHS [J].
BEARDEN, JA .
REVIEWS OF MODERN PHYSICS, 1967, 39 (01) :78-&
[10]  
Berger M., NIST, PML, DOI DOI 10.18434/T48G6X