Double Duct Packed Bed Solar Air Heater Under Combined Single and Recyclic Double Air Pass

被引:9
作者
Singh, Satyender [1 ]
Dhiman, Prashant [1 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Hamirpur 177005, HP, India
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2016年 / 138卷 / 01期
关键词
PARALLEL-PLATE CHANNEL; THERMAL PERFORMANCE; THERMOHYDRAULIC PERFORMANCE; TRANSFER ENHANCEMENT; EXTERNAL RECYCLE; MASS-TRANSFER; FLOW; IMPROVEMENT; COLLECTOR; COUNTER;
D O I
10.1115/1.4032142
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present work intended to investigate thermal and thermohydraulic efficiencies of two different models of recyclic double pass packed bed solar air heaters experimentally. Model-I consists of single air pass through two glass covers as well as double air pass caused due to recycle of the air exiting from the packed bed duct formed between the absorber plate and the glass cover through another duct integrated between the absorber and back plates to inlet of the packed bed duct. On the other hand, model-II consists of only double air pass originated due to recycle operation constituted between the similar solar air heater elements as that of model-I. Twelve numbers of wire mesh screens to form 95% bed porosity were used. Both solar air heater models were tested under the range of packed bed Reynolds number from 300 to 1500 for air mass flow rate and recycle ratio of 0.01 kg/s to 0.025 kg/s and 0.3 to 1.8, respectively. Results revealed that thermal performance of model-I is found to be 15% higher than that of model-II. The optimum value of the recycle ratio for model-I and model-II are obtained as 0.9 and 1.2, respectively, at a mass flow rate of 0.025 kg/s that yields the best thermohydraulic efficiency of 77% and 67%, respectively. Moreover, optimum solution for recycle ratio and air mass flow rate during off sun shine hours are also obtained and presented in the current work.
引用
收藏
页数:7
相关论文
共 46 条
[1]  
[Anonymous], 1977, ASHRAE Standard 93-97
[2]   PERFORMANCE ANALYSIS OF SOLAR AIR HEATERS OF CONVENTIONAL DESIGN [J].
BIONDI, P ;
CICALA, L ;
FARINA, G .
SOLAR ENERGY, 1988, 41 (01) :101-107
[3]   Recyclic double pass packed bed solar air heaters [J].
Dhiman, Prashant ;
Singh, Satyender .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 87 :215-227
[4]   Thermal and thermohydraulic performance of counter and parallel flow packed bed solar air heaters [J].
Dhiman, Prashant ;
Thakur, N. S. ;
Chauhan, S. R. .
RENEWABLE ENERGY, 2012, 46 :259-268
[5]   An analytical model to predict the thermal performance of a novel parallel flow packed bed solar air heater [J].
Dhiman, Prashant ;
Thakur, N. S. ;
Kumar, Anoop ;
Singh, Satyender .
APPLIED ENERGY, 2011, 88 (06) :2157-2167
[6]   Year round performance of double pass solar air heater with packed bed [J].
El-Sebaii, A. A. ;
Aboul-Enein, S. ;
Ramadan, M. R. I. ;
El-Bialy, E. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (03) :990-1003
[7]   Thermal performance investigation of double pass-finned plate solar air heater [J].
El-Sebaii, A. A. ;
Aboul-Enein, S. ;
Ramadan, M. R. I. ;
Shalaby, S. M. ;
Moharram, B. M. .
APPLIED ENERGY, 2011, 88 (05) :1727-1739
[8]   Experimental and simulation studies on a single pass, double duct solar air heater [J].
Forson, FK ;
Nazha, MAA ;
Rajakaruna, H .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (08) :1209-1227
[9]   Thermohydraulic performance of air heating solar collectors with variable width, flat absorber plates [J].
Hegazy, AA .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (13) :1361-1378
[10]   Performance of flat plate solar air heaters with optimum channel geometry for constant/variable flow operation [J].
Hegazy, AA .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (04) :401-417