Characterization of gastric volume responses and liquid emptying in functional dyspepsia and health by MRI or barostat and simultaneous 13C-acetate breath test

被引:26
|
作者
Fruehauf, H. [1 ]
Steingoetter, A. [2 ,3 ]
Fox, M. R. [1 ,4 ]
Kwiatek, M. A. [1 ]
Boesiger, P. [2 ,3 ]
Schwizer, W. [1 ,4 ]
Fried, M. [1 ,4 ]
Thumshirn, M. [1 ]
Goetze, O. [1 ]
机构
[1] Univ Zurich Hosp, Dept Gastroenterol & Hepatol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] ETH, Inst Biomed Engn, Zurich, Switzerland
[4] Univ Zurich, Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
C-13-sodium acetate breath test; functional dyspepsia; gastric barostat; gastric emptying; gastric volume response; magnetic resonance imaging; SENSORY FUNCTION; MOTOR FUNCTION; TEST MEALS; HUMANS; MOTILITY; DISTENSION; SECRETION; PATHOPHYSIOLOGY; QUANTIFICATION; ACCOMMODATION;
D O I
10.1111/j.1365-2982.2009.01267.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The assessment of gastric accommodation and emptying by different methodologies provides inconsistent results. We aimed to compare magnetic resonance imaging (MRI), barostat and C-13-acetate breath test (BT) for the assessment of gastric volume responses and emptying in healthy controls (HC) and patients with functional dyspepsia (FD). Eight HC and eight FD patients underwent: (i) continuous BT with simultaneous MRI in the upright position after ingestion of isocaloric, 300 kcal, 200 and 800 mL meals, both labelled with 100 mg of C-13-acetate; and (ii) BT with gastric barostat after ingestion of the 200 mL meal. MRI measured total gastric volume and gastric content volume (GCV) at baseline, after filling and during emptying. Meal emptying half-times (T1/2) for MRI and BT were calculated (mean +/- SD). We found: (i) Initial GCV was lower in FD than in HC (762 +/- 22 vs 810 +/- 52 mL, P < 0.04) after the 800 mL meal but not the 200 mL meal. T1/2(MRI) was shorter for the 800 mL than the 200 mL meal (P < 0.001), but similar in HC and FD (200 mL: HC 117 +/- 30 min vs FD 138 +/- 42 min, ns; 800 mL: HC 71 +/- 16 min vs FD 78 +/- 27 min, ns). In contrast, T1/2(BT) was similar between meals and groups (200 mL: HC 111 +/- 11 min vs FD 116 +/- 19 min; 800 mL: HC 114 +/- 14 min vs FD: 113 +/- 17 min). (ii) Barostat measurements showed similar postprandial volume increases between groups. We conclude that direct measurements by MRI provide a sensitive, non-invasive assessment of gastric accommodation and emptying after a meal. In contrast to MRI, BT did not detect faster emptying of high-volume compared to low-volume liquid nutrient meals in HC or FD.
引用
收藏
页码:697 / E37
页数:12
相关论文
共 33 条
  • [21] 13C-sodium acetate breath test for evaluation of gastric emptying times in dogs with gastric dilatation-volvulus
    Schmitz, S.
    Jansen, N.
    Failing, K.
    Neiger, R.
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2013, 41 (02): : 87 - 92
  • [22] Is there a difference in gastric emptying between Parkinson's disease patients under long-term l-dopa therapy with and without motor fluctuations? An analysis using the 13C-acetate breath test
    Tanaka, Yuji
    Kato, Tomohiro
    Nishida, Hiroshi
    Araki, Hiroshi
    Murase, Masahiko
    Nagaki, Masahito
    Moriwaki, Hisataka
    Inuzuka, Takashi
    JOURNAL OF NEUROLOGY, 2009, 256 (12) : 1972 - 1976
  • [23] Prospective randomized controlled study of gastric emptying assessed by 13C-acetate breath test after pylorus-preserving pancreaticoduodenectomy: comparison between antecolic and vertical retrocolic duodenojejunostomy
    Chijiiwa, Kazuo
    Imamura, Naoya
    Ohuchida, Jiro
    Hiyoshi, Masahide
    Nagano, Motoaki
    Otani, Kazuhiro
    Kai, Masahiro
    Kondo, Kazuhiro
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SURGERY, 2009, 16 (01): : 49 - 55
  • [24] Is there a difference in gastric emptying between Parkinson’s disease patients under long-term l-dopa therapy with and without motor fluctuations? An analysis using the 13C-acetate breath test
    Yuji Tanaka
    Tomohiro Kato
    Hiroshi Nishida
    Hiroshi Araki
    Masahiko Murase
    Masahito Nagaki
    Hisataka Moriwaki
    Takashi Inuzuka
    Journal of Neurology, 2009, 256 : 1972 - 1976
  • [25] Simultaneous Measurement of Gastric Emptying with a Simple Muffin Meal Using [13C]Octanoate Breath Test and Scintigraphy in Normal Subjects and Patients with Dyspeptic Symptoms
    Matthew Q. Bromer
    Steve B. Kantor
    David A. Wagner
    Linda C. Knight
    Alan H. Maurer
    Henry P. Parkman
    Digestive Diseases and Sciences, 2002, 47 : 1657 - 1663
  • [26] Simultaneous measurement of gastric emptying with a simple muffin meal using [13C]octanoate breath test and scintigraphy in normal subjects and patients with dyspeptic symptoms
    Bromer, MQ
    Kantor, SB
    Wagner, DA
    Knight, LC
    Maurer, AH
    Parkman, HP
    DIGESTIVE DISEASES AND SCIENCES, 2002, 47 (07) : 1657 - 1663
  • [27] Solid phase gastric emptying times in the dog measured by 13C-sodium-acetate breath test and 99mTechnetium radioscintigraphy
    Schmitz, S.
    Failing, K.
    Neiger, R.
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2010, 38 (04): : 211 - 216
  • [28] Gastric emptying measurement of liquid nutrients using the 13C-octanoate breath test in critically ill patients: a comparison with scintigraphy
    Nam Q. Nguyen
    Laura K. Bryant
    Carly M. Burgstad
    Marianne Chapman
    Adam Deane
    Max Bellon
    Kylie Lange
    Dylan Bartholomeuz
    Michael Horowitz
    Richard H. Holloway
    Robert J. Fraser
    Intensive Care Medicine, 2013, 39 : 1238 - 1246
  • [29] Gastric emptying measurement of liquid nutrients using the 13C-octanoate breath test in critically ill patients: a comparison with scintigraphy
    Nguyen, Nam Q.
    Bryant, Laura K.
    Burgstad, Carly M.
    Chapman, Marianne
    Deane, Adam
    Bellon, Max
    Lange, Kylie
    Bartholomeuz, Dylan
    Horowitz, Michael
    Holloway, Richard H.
    Fraser, Robert J.
    INTENSIVE CARE MEDICINE, 2013, 39 (07) : 1238 - 1246
  • [30] Effect of meal size and test duration on gastric emptying and gastric myoelectrical activity as determined with simultaneous [13C]octanoate breath test and electrogastrography in normal subjects using a muffin meal
    Gonlachanvit, S
    Chey, WD
    Goodman, KJ
    Parkman, HP
    DIGESTIVE DISEASES AND SCIENCES, 2001, 46 (12) : 2643 - 2650