Effectiveness of SO2 emission control policy on power plants in the Yangtze River Delta, China-post-assessment of the 11th Five-Year Plan

被引:13
作者
Tan, Jiani [1 ]
Fu, Joshua S. [1 ]
Huang, Kan [1 ,2 ]
Yang, Cheng-En [1 ]
Zhuang, Guoshun [2 ]
Sun, Jian [1 ]
机构
[1] Univ Tennessee, Dept Civil & Environm Engn, Knoxville, TN 37996 USA
[2] Fudan Univ, Dept Environm Sci & Engn, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
Post-assessment; Air quality modeling; 11th Five-Year Plan; SO2 emission control; WRF/CMAQ; Yangtze River Delta; POLLUTION CONTROL POLICIES; AIR-QUALITY BENEFITS; SULFUR-DIOXIDE; INORGANIC AEROSOLS; CONTROL STRATEGIES; NO2; COLUMNS; INTEX-B; POLLUTANTS; MEGACITIES;
D O I
10.1007/s11356-017-8412-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Facing the air pollution problems in China, emission control strategies have been implemented within the framework of national Five-Year Plan (FYP). According to the lack of post-assessment studies in the literature, this study assessed the effectiveness of the SO2 emission control policies on power plants after the 11th FYP (2006-2010) by modeling emission control scenarios. The idealized emission control policy (the PS90 scenario with assumption of 90% SO2 emission reduction from power plants) could reduce the SO2 and SO42- concentrations by about 51 and 14%, respectively, over the Yangtze River Delta region. While the actual emission control condition (the P2010 scenario based on the actual emissions from power plants in 2010) demonstrated that the actual reduction benefits were 30% of SO2 and 9% of SO42-. On the city scale, the P2010 scenario imposed positive benefits on Shanghai, Nanjing, Nantong, and Hangzhou with SO2 reductions of about 55, 12, 30, and 21%, respectively, while an 11% increase of SO2 concentration was found in Ningbo. The number of days exceeding China's National Ambient Air Quality Standard of Class I daily SO2 concentration was estimated to be 75, 52, 7, 77, and 40 days for Shanghai, Nanjing, Nantong, Ningbo, and Hangzhou under the real SO2 control condition (P2010). The numbers could be decreased by 16, 11, 2, 21, and 11% if the control effect reaches the level of the PS90 scenario. This study serves as a scientific basis to design capable enforcement of emission control strategies in China in the future national plans.
引用
收藏
页码:8243 / 8255
页数:13
相关论文
共 37 条
[1]   China's 11th Five-Year Plan and the Environment: Reducing SO2 Emissions [J].
Cao, Jing ;
Garbaccio, Richard ;
Ho, Mun S. .
REVIEW OF ENVIRONMENTAL ECONOMICS AND POLICY, 2009, 3 (02) :231-250
[2]   Inorganic aerosols responses to emission changes in Yangtze River Delta, China [J].
Dong, Xinyi ;
Li, Juan ;
Fu, Joshua S. ;
Gao, Yang ;
Huang, Kan ;
Zhuang, Guoshun .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 481 :522-532
[3]   Probe into gaseous pollution and assessment of air quality benefit under sector dependent emission control strategies over megacities in Yangtze River Delta, China [J].
Dong, Xinyi ;
Gao, Yang ;
Fu, Joshua S. ;
Li, Juan ;
Huang, Kan ;
Zhuang, Guoshun ;
Zhou, Ying .
ATMOSPHERIC ENVIRONMENT, 2013, 79 :841-852
[4]  
Fang M, 2008, Master's Thesis
[5]   Emission inventory of primary pollutants and chemical speciation in 2010 for the Yangtze River Delta region, China [J].
Fu, Xiao ;
Wang, Shuxiao ;
Zhao, Bin ;
Xing, Jia ;
Cheng, Zhen ;
Liu, Huan ;
Hao, Jiming .
ATMOSPHERIC ENVIRONMENT, 2013, 70 :39-50
[6]   A comparison study between CMAQ-simulated and OMI-retrieved NO2 columns over East Asia for evaluation of NOx emission fluxes of INTEX-B, CAPSS, and REAS inventories [J].
Han, K. M. ;
Lee, S. ;
Chang, L. S. ;
Song, C. H. .
ATMOSPHERIC CHEMISTRY AND PHYSICS, 2015, 15 (04) :1913-1938
[7]   A comparison study between model-predicted and OMI-retrieved tropospheric NO2 columns over the Korean peninsula [J].
Han, K. M. ;
Lee, C. K. ;
Lee, J. ;
Kim, J. ;
Song, C. H. .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (17) :2962-2971
[8]   Space-based measurements of air quality during the World Expo 2010 in Shanghai [J].
Hao, N. ;
Valks, P. ;
Loyola, D. ;
Cheng, Y. F. ;
Zimmer, W. .
ENVIRONMENTAL RESEARCH LETTERS, 2011, 6 (04)
[9]   How to improve the air quality over megacities in China: pollution characterization and source analysis in Shanghai before, during, and after the 2010 World Expo [J].
Huang, K. ;
Zhuang, G. ;
Lin, Y. ;
Wang, Q. ;
Fu, J. S. ;
Fu, Q. ;
Liu, T. ;
Deng, C. .
ATMOSPHERIC CHEMISTRY AND PHYSICS, 2013, 13 (12) :5927-5942
[10]   Role of sectoral and multi-pollutant emission control strategies in improving atmospheric visibility in the Yangtze River Delta, China [J].
Huang, Kan ;
Fu, Joshua S. ;
Gao, Yang ;
Dong, Xinyi ;
Zhuang, Guoshun ;
Lin, Yanfen .
ENVIRONMENTAL POLLUTION, 2014, 184 :426-434