Exergoeconomic optimization of a novel cascade Kalina/Kalina cycle using geothermal heat source and LNG cold energy recovery

被引:125
作者
Ghaebi, Hadi [1 ]
Namin, Amin Shekari [1 ]
Rostamzadeh, Hadi [1 ]
机构
[1] Univ Mohaghegh Ardabili, Fac Engn, Dept Mech Engn, POB 179, Ardebil, Iran
关键词
Kalina cycle (KC); Cascade power plant; LNG; Geothermal; Exergoeconomic; Optimization; ORGANIC RANKINE-CYCLE; COMPARATIVE THERMODYNAMIC ANALYSIS; EXERGY ANALYSIS; WASTE HEAT; KALINA CYCLE; PUMP SYSTEM; THERMOECONOMIC ANALYSIS; COGENERATION SYSTEM; COMBINED POWER; ORC;
D O I
10.1016/j.jclepro.2018.04.049
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent studies, cascade power generation systems are introduced as promising methodologies in power plants for recovering the waste heat of topping cycle, resulting in low waste heat rejection from the heat exchangers of the single-stage power plant. Due to the importance of this topic, a cascade Kalina cycle (CKC) power plant is proposed using geothermal energy as heat source and liquefied natural gas (LNG) as thermal heat sink. The proposed system is integrated from a high pressure KC (HPKC) as topping cycle and a low pressure KC (LPKC) as bottoming cycle. Energy, exergy and exergoeconomic analysis of the proposed system are conducted to give more detail information for designers. In addition, single- and multi-objective optimizations of the proposed system are performed, using genetic algorithm (GA) method. It is demonstrated that the optimum net power, thermal efficiency, exergy efficiency and total sum unit cost of product of the proposed system can be obtained 9044 kW, 29.87%, 43.19% and 127.8 $/GJ, respectively. Exergy analysis results demonstrated that among all components, the second heat exchanger accounts for the biggest exergy destruction rate. To obtain a better understanding from characteristics of the proposed system, a comprehensive parametric study is conducted showing that the thermal efficiency of system can be optimized based on the geothermal inlet temperature as well as the basic ammonia concentrations of HPKC and LPKC. In addition, it is found that a higher thermal efficiency can be obtained by increasing vapor generator pinch point temperature difference and turbines expansion ratio or by decreasing the second heat exchanger's temperature. Moreover, it is concluded that the exergy efficiency can be increased by increasing the first and second turbines' expansion ratios, geothermal inlet temperature, and basic ammonia concentration of HPKC or by decreasing the second heat exchanger's temperature, third turbine's expansion ratio and vapor generator pinch point temperature difference. In addition, the total sum unit cost of product of system can be decreased by increasing of the geothermal inlet temperature, second heat exchanger temperature, basic ammonia concentration of HPKC and basic ammonia concentration of LPKC or by decreasing of the vapor generator pinch point temperature difference and turbines' expansion ratios. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:279 / 296
页数:18
相关论文
共 53 条
[1]   Empirical Models for a Screw Expander Based on Experimental Data From Organic Rankine Cycle System Testing [J].
Avadhanula, Vamshi Krishna ;
Lin, Chuen-Sen .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2014, 136 (06)
[2]   Strengthening power generation efficiency utilizing liquefied natural gas cold energy by a novel two-stage condensation Rankine cycle (TCRC) system [J].
Bao, Junjiang ;
Lin, Yan ;
Zhang, Ruixiang ;
Zhang, Ning ;
He, Gaohong .
ENERGY CONVERSION AND MANAGEMENT, 2017, 143 :312-325
[3]   Exergy analysis and parameter study on a novel auto-cascade Rankine cycle [J].
Bao, Junjiang ;
Zhao, Li .
ENERGY, 2012, 48 (01) :539-547
[4]   A novel ammonia-water combined power and refrigeration cycle with two different cooling temperature levels [J].
Barkhordarian, Orbel ;
Behbahaninia, Ali ;
Bahrampoury, Rasool .
ENERGY, 2017, 120 :816-826
[5]  
Bejan A., 1995, Thermal design and optimization
[6]   A novel cascade organic Rankine cycle (ORC) system for waste heat recovery of truck diesel engines [J].
Chen, Tao ;
Zhuge, Weilin ;
Zhang, Yangjun ;
Zhang, Lei .
ENERGY CONVERSION AND MANAGEMENT, 2017, 138 :210-223
[7]   Analysis and optimization of cascade Rankine cycle for liquefied natural gas cold energy recovery [J].
Choi, In-Hwan ;
Lee, Sangick ;
Seo, Yutaek ;
Chang, Daejun .
ENERGY, 2013, 61 :179-195
[8]   Technoeconomic appraisal of a ground source heat pump system for a heating season in eastern Turkey [J].
Esen, H ;
Inalli, M ;
Esen, M .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (9-10) :1281-1297
[9]   Energy and exergy analysis of a ground-coupled heat pump system with two horizontal ground heat exchangers [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Esen, Mehmet ;
Pihtili, Kazim .
BUILDING AND ENVIRONMENT, 2007, 42 (10) :3606-3615
[10]   A techno-economic comparison of ground-coupled and air-coupled heat pump system for space cooling [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Esen, Mehmet .
BUILDING AND ENVIRONMENT, 2007, 42 (05) :1955-1965