Solvent systems with n-hexane and/or cyclohexane in countercurrent chromatography-Physico-chemical parameters, and their impact on the separation of alkyl hydroxybenzoates

被引:15
作者
Englert, Michael [1 ]
Vetter, Walter [1 ]
机构
[1] Univ Hohenheim, Inst Food Chem, D-70599 Stuttgart, Germany
关键词
Countercurrent chromatography; Solvents; Separation efficiency; Alkyl hydroxybenzoates; Physico-chemical parameters; PURIFICATION;
D O I
10.1016/j.chroma.2014.03.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Countercurrent chromatography (CCC) is an efficient preparative separation technique based on the liquid-liquid distribution of compounds between two phases of a biphasic liquid system. The crucial parameter for the successful application is the selection of the solvent system. Especially for nonpolar analytes the selection options are limited. On the search for a suitable solvent system for the separation of an alkyl hydroxybenzoate homologous series, we noted that the substitution of cyclohexane with n-hexane was accompanied with unexpected differences in partitioning coefficients of the individual analytes. In this study, we investigated the influence of the subsequent substitution of n-hexane with cyclohexane in the n-hexane/cyclohexane/tert-butylmethylether/methanol/water solvent system family. Exact phase compositions and polarity, viscosity and density differences were determined to characterize the different mixtures containing n-hexane and/or cyclohexane. Findings were confirmed by performing CCC separations with different mixtures, which led to baseline resolution for positional isomers when increasing the amount of cyclohexane while the resolution between two pairs of structural isomers decreased. With the new methodology described, structurally similar compounds could be resolved by choosing a certain ratio of n-hexane to cyclohexane. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 24 条
  • [1] Alkane effect in the Arizona liquid systems used in countercurrent chromatography
    Berthod, A
    Hassoun, M
    Ruiz-Angel, MJ
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 327 - 340
  • [2] Berthod A., 2002, COMPREHENSIVE ANAL C, P365
  • [3] COUNTERCURRENT CHROMATOGRAPHY IN ANALYTICAL CHEMISTRY (IUPAC Technical Report)
    Berthod, Alain
    Maryutina, Tatyana
    Spivakov, Boris
    Shpigun, Oleg
    Sutherland, Ian A.
    [J]. PURE AND APPLIED CHEMISTRY, 2009, 81 (02) : 355 - 387
  • [4] HSCCC-MS study of flavonoids in the extracts from the seeds of Oroxylum indicum
    Chen, LJ
    Song, H
    Games, DE
    Sutherland, IA
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (12-13) : 1993 - 2003
  • [5] Conway W. D., 1990, THEORY APPL, p[29, 36]
  • [6] Fractionation of Gallotannins from Mango (Mangifera indica L.) Kernels by High-Speed Counter-Current Chromatography and Determination of Their Antibacterial Activity
    Engels, Christina
    Gaenzle, Michael G.
    Schieber, Andreas
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (02) : 775 - 780
  • [7] Modulation of T lymphocyte and eosinophil functions in vitro by natural tetranortriterpenoids isolated from Carapa guianensis Aublet
    Ferraris, Fausto K.
    Rodrigues, Rodrigo
    da Silva, Vagner P.
    Figueiredo, Raquel
    Penido, Carmen
    Henriques, Maria das Gracas M. O.
    [J]. INTERNATIONAL IMMUNOPHARMACOLOGY, 2011, 11 (01) : 1 - 11
  • [8] Counter-current chromatography: instrumentation, solvent selection and some recent applications to natural product purification
    Foucault, AP
    Chevolot, L
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) : 3 - 22
  • [9] GUESS - A generally useful estimate of solvent systems in CCC
    Friesen, JB
    Pauli, GF
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (17) : 2777 - 2806
  • [10] DEVELOPMENT OF A PHASE SYSTEM FOR INTERMEDIATE POLARITY COMPOUNDS IN CENTRIFUGAL PARTITION CHROMATOGRAPHY
    GLUCK, SJ
    WINGEIER, MP
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2): : 69 - 78