Proximal femoral canal shape is more accurately assessed on AP hip radiographs than AP pelvis radiographs in primary hip osteoarthritis

被引:5
作者
Merle, Christian [1 ,2 ]
Waldstein, Wenzel [1 ,2 ]
Gregory, Jennifer S. [3 ]
Goodyear, Simon R. [3 ]
Aspden, Richard M. [3 ]
Aldinger, Peter R. [4 ]
Murray, David W. [2 ]
Gill, Harinderjit S. [5 ]
机构
[1] Univ Heidelberg Hosp, Dept Traumat & Orthopaed Surg, D-69118 Heidelberg, BW, Germany
[2] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford, England
[3] Univ Aberdeen, Musculoskeletal Res Programme, Div Appl Med, Aberdeen, Scotland
[4] Paulinenhilfe Diakonie Klinikum Stuttgart, Dept Orthopaed Surg, Stuttgart, Germany
[5] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
关键词
Hip; Arthroplasty; Planning; Canal shape; Radiographs; CT; ARTHROPLASTY; FEMUR; BONE; STEM; ANTEVERSION; NECK; FIT; ENDOPROSTHESIS; EPIDEMIOLOGY; MORPHOLOGY;
D O I
10.5301/hipint.5000040
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objectives of the present study were to determine (1) whether differences in the radiographic appearance of the of the proximal femoral canal exist on corresponding AP pelvis and AP hip radiographs, and (2) whether radiographic assessment of canal shape is accurate with reference to computed tomography (CT). In a retrospective study, corresponding radiographs and CT scans of 100 consecutive patients with primary hip OA were evaluated. Active shape modelling (ASM) was performed to assess the variation in proximal femoral canal shape and to identify differences between AP hip and AP pelvis views. Differences in the medial cortical flare between radiographs and CT were quantified using least squares curve fitting. ASM identified significant differences in the assessment of canal shape on corresponding AP hip and AP pelvis views. Curve fitting demonstrated a good agreement between AP hip radiographs and CT. Agreement between AP pelvis radiographs and CT was less good. In contrast to AP pelvis radiographs, AP hip radiographs allow a more accurate and reliable assessment of proximal femoral canal shape in the frontal plane in primary hip OA. Our findings may improve stem fit in total hip arthroplasty without the routine use of CT.
引用
收藏
页码:484 / 491
页数:8
相关论文
共 41 条
[1]   Survival of the Cementless SpotornoA® Stem in the Second Decade [J].
Aldinger, Peter R. ;
Jung, Alexander W. ;
Breusch, Steffen J. ;
Ewerbeck, Volker ;
Parsch, Dominik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2297-2304
[2]   Uncemented Grit-Blasted Straight Tapered Titanium Stems in Patients Younger than Fifty-five Years of Age Fifteen to Twenty-Year Results [J].
Aldinger, Peter R. ;
Jung, Alexander W. ;
Pritsch, Maria ;
Breusch, Steffen ;
Thomsen, Marc ;
Ewerbeck, Volker ;
Parsch, Dominik .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06) :1432-1439
[3]   Active Shape Modeling of the Hip in the Prediction of Incident Hip Fracture [J].
Baker-LePain, Julie C. ;
Luker, Kali R. ;
Lynch, John A. ;
Parimi, Neeta ;
Nevitt, Michael C. ;
Lane, Nancy E. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2011, 26 (03) :468-474
[4]   Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years - A concise follow-up of previous reports [J].
Belmont, Philip J., Jr. ;
Powers, Cara C. ;
Beykirch, Sarah E. ;
Hopper, Robert H., Jr. ;
Engh, C. Anderson, Jr. ;
Engh, Charles A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (07) :1524-1530
[5]   Epidemiology - Hip and knee [J].
Berry, DJ .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :183-+
[6]   Minimally invasive total hip arthroplasty - Development, early results, and a critical analysis [J].
Berry, DJ ;
Berger, RA ;
Callaghan, JJ ;
Dorr, LD ;
Duwelius, PJ ;
Hartzband, MA ;
Lieberman, JR ;
Mears, DC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2235-2236
[7]   MICROMOTION OF CEMENTED AND UNCEMENTED FEMORAL COMPONENTS [J].
BURKE, DW ;
OCONNOR, DO ;
ZALENSKI, EB ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :33-37
[8]   THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS [J].
CALLAGHAN, JJ ;
FULGHUM, CS ;
GLISSON, RR ;
STRANNE, SK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :839-848
[9]   EFFECT OF MOVEMENT ON BONDING OF POROUS METAL TO BONE [J].
CAMERON, HU ;
PILLIAR, RM ;
MACNAB, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (04) :301-311
[10]   Validity and Reliability of Measuring Femoral Anteversion and Neck-Shaft Angle in Patients with Cerebral Palsy [J].
Chung, Chin Youb ;
Lee, Kyoung Min ;
Park, Moon Seok ;
Lee, Sang Hyeong ;
Choi, In Ho ;
Cho, Tae-Joon .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05) :1195-1205