Precision of tibial cartilage morphometry with a coronal water-excitation MR sequence

被引:54
作者
Hyhlik-Dürr, A
Faber, S
Burgkart, R
Stammberger, T
Maag, KP
Englmeier, KH
Reiser, M
Eckstein, F
机构
[1] Univ Munich, Musculoskeletal Res Grp, Inst Anat, D-80336 Munich, Germany
[2] Univ Munich, Inst Radiol Diagnost, Klinikum, D-81377 Munich, Germany
[3] Tech Univ Munich, Klin Orthopad & Sportorthopad, D-81675 Munich, Germany
[4] GSF Forschungszentrum Umwelt & Gesundheit, Inst Med Informat & Syst Forsch, D-85764 Oberschleissheim, Germany
[5] Univ Munich, Klinikum Grosshadern, Inst Med Informat Verarbeitung Biometrie & Epidem, D-81377 Munich, Germany
关键词
cartilage; MR imaging; precision; joint; osteoarthritis;
D O I
10.1007/s003300050047
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to analyze the precision of tibial cartilage morphometry, by using a coronal water-excitation sequence with high spatial resolution,to compare the reproducibility of 3D thickness vs volume estimates, and to test the technique patients with severe osteoarthritis. The tibiae of 8 healthy volunteers and 3 patients selected for total knee arthroplasty were imaged repeatedly with a water-excitation sequence (image time 6 h 19 min, resolution 1.2 x 0.31 x 0.31 mm(3)), with the knee being repositioned between each replicate acquisition. er 3D reconstruction, the cartilage volume, the mean and the maximal tibial cartilage thickness determined by:3D Euclidean distance transformation. In the volunteers, the precision of the volume measurements was 2.3% (CV%) in the medial and in the lateral tibia. The reproducibility of the mean cartilage thickness was similar (2.6 and 2.5%, respectively), and that of the maximal thickness lower (6.5 and 4.4%). The patients showed a considerable function in volume and thickness, the precision comparable with that in the volunteers. We find using a new imaging protocol and computational algorithm, it is possible to determine tibial cartilage morphometry with high precision in healthy individuals as in patients with osteoarthritis.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 24 条
  • [1] INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY
    BARTKO, JJ
    [J]. PSYCHOLOGICAL REPORTS, 1966, 19 (01) : 3 - &
  • [2] Articular cartilage .2. Degeneration and osteoarthrosis, repair, regeneration, and transplantation
    Buckwalter, JA
    Mankin, HJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (04) : 612 - 632
  • [3] SHOULD PERIMENOPAUSAL WOMEN BE SCREENED FOR OSTEOPOROSIS
    CUMMINGS, SR
    BLACK, D
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 104 (06) : 817 - 823
  • [4] Eckstein F, 1998, CLIN ORTHOP RELAT R, P137
  • [5] Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)
    Eckstein, F
    Gavazzeni, A
    Sittek, H
    Haubner, M
    Losch, A
    Milz, S
    Englmeier, KH
    Schulte, E
    Putz, R
    Reiser, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 256 - 265
  • [6] In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging
    Eckstein, F
    Westhoff, J
    Sittek, H
    Maag, KP
    Haubner, M
    Faber, S
    Englmeier, KH
    Reiser, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (03) : 593 - 597
  • [7] Effect of physical exercise on cartilage volume and thickness in vivo: MR imaging study
    Eckstein, F
    Tieschky, M
    Faber, SC
    Haubner, M
    Kolem, H
    Englmeier, KH
    Reiser, M
    [J]. RADIOLOGY, 1998, 207 (01) : 243 - 248
  • [8] ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES
    GLUER, CC
    BLAKE, G
    LU, Y
    BLUNT, BA
    JERGAS, M
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) : 262 - 270
  • [9] GRAICHEN H, IN PRESS OSTEOARTHRI
  • [10] Hassager C, 1991, Osteoporos Int, V1, P250