Short-term absorbable material for diaphragmatic replacement

被引:3
作者
Steinau, G [1 ]
Dreuw, B [1 ]
Schleef, J [1 ]
Lawong, G [1 ]
Schumpelick, V [1 ]
机构
[1] Rheinish Westphalian Tech Univ Aachen, Surg Clin, D-52057 Aachen, Germany
关键词
diaphragmatic replacement; absorbable material; experimental study;
D O I
10.1007/s003830050005
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To evaluate absorbable materials for use for replacement of the diaphragm, we implanted materials in experimentally-created diaphragmatic defects in pigs. As a short-term absorbable material, bovine serosa (BS) was used. Its absorption was complete after 4-6 weeks. In a control group, the defect was repaired with a continuous running polypropylene suture. In two other groups the defect was closed with lyophilized dura (LD) and a modified transverse abdominal muscle flap according to Hecker, respectively. Physical studies (load capacity and elasticity) and histologic investigations were performed in one-half of the animals of each group after 3 and 6 months, respectively. Considering their physical properties, it could be shown that all materials tested are suitable for replacement of the diaphragm, but that BS best resembled native diaphragm. We conclude that short-term absorbable BS is suitable for replacement of the diaphragm in pigs.