An Improved Design of Current Controller for LCL-Type Grid-Connected Converter to Reduce Negative Effect of PLL in Weak Grid

被引:151
作者
Zhou, Shiying [1 ]
Zou, Xudong [1 ]
Zhu, Donghai [1 ]
Tong, Li [2 ]
Zhao, Yingying [3 ]
Kang, Yong [1 ]
Yuan, Xiaoming [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Zhejiang Elect Power Corp Res Inst, Hangzhou 310014, Zhejiang, Peoples R China
[3] State Grid Anhui Econ Res Inst, Hefei 230000, Anhui, Peoples R China
关键词
Current controller; grid-connected converter; phase-locked loop (PLL); small-signal impedance model; weak grid; CONTROL STRATEGY; VECTOR CONTROL; VOLTAGE; STABILITY; INVERTER; FILTERS;
D O I
10.1109/JESTPE.2017.2780918
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For three-phase LCL-type grid-connected converter, when it is attached to weak grid, current control interacts with phase-locked loop (PLL) via point of common coupling voltage. Consequently, PLL dynamic might deteriorate grid current control and even result in system instability. However, the conventional design method of current controller neglects the impact of PLL, and therefore, it is hard for the current controller to mitigate the negative effect of PLL. In this paper, an improved design of current controller, i.e., proportional-integral controller and capacitor-current-feedback active damping, is proposed to reduce the negative effect of PLL on current control. First, a small-signal impedance model is developed to analyze the impact of PLL on current control. Then, the effect of current controller parameters on the converter output impedance is analyzed, and a design guideline to improve the current controller parameters is presented. With the improved parameters, in precondition of satisfying system stability margin under both stiff and weak grid, the negative effect of PLL on current control can be effectively mitigated without employing additional control strategies. Furthermore, the current control has a strong robustness against wide-range variation of grid impedance. Finally, the experiment demonstrates the effectiveness of the proposed design method.
引用
收藏
页码:648 / 663
页数:16
相关论文
共 50 条
  • [41] A Joint Active Damping Strategy Based on LCL-Type Grid-Connected Inverters for Grid Current Feedback and PCC Voltage Unit Feedforward
    Ke, Shanwen
    Liang, Bo
    SENSORS, 2024, 24 (18)
  • [42] Capacitor Current Feedback With Phase-Lead Compensator to Eliminate Resonant Frequency Forbidden Region for LCL-Type Grid-Connected Inverter in Weak Grid
    Fang, Tianzhi
    Shen, Shuheng
    Zhang, Li
    Jin, Yinglin
    Huang, Chun
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (05) : 5581 - 5596
  • [43] An Improved Three-Stages Cascading Passivity-Based Control of Grid-Connected LCL Converter in Unbalanced Weak Grid Condition
    Li, Jianguo
    Zhang, Yajing
    Zhao, Yuming
    Ren, Li
    Wang, Jiuhe
    Liu, Yufan
    IEEE ACCESS, 2021, 9 : 89497 - 89506
  • [44] Passivity-Based Design of External Passive Damper for LCL-Type Grid-Connected Inverter
    Ma, Guangda
    Xie, Chuan
    Li, Cheng
    Peng, Chao
    Zou, Jianxiao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (09) : 11558 - 11570
  • [45] Combined filtering feedforward control strategy for LCL-type grid-connected inverters
    Zhang L.
    Jin Y.
    Pan G.
    Wang J.
    Ouyang K.
    Jin L.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (12): : 388 - 394
  • [46] Modeling and Stability Analysis of LCL-Type Grid-Connected Inverters: A Comprehensive Overview
    Han, Yang
    Yang, Mengling
    Li, Hong
    Yang, Ping
    Xu, Lin
    Alves Coelho, Ernane Antonio
    Guerrero, Josep M.
    IEEE ACCESS, 2019, 7 : 114975 - 115001
  • [47] An Improved Resonant Frequency Based Systematic LCL Filter Design Method for Grid-Connected Inverter
    Wu, Tsai-Fu
    Misra, Mitradatta
    Lin, Li-Chiun
    Hsu, Chih-Wei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (08) : 6412 - 6421
  • [48] Integrated design method for LCL-type filter and current controller to improve inverter adaptability to grid impedance
    Zheng, Chen
    Liu, Yajuan
    Li, Qionglin
    Liu, Shuming
    Zhang, Bo
    Wang, Yi
    Mao, Mingxuan
    IET POWER ELECTRONICS, 2019, 12 (12) : 3295 - 3305
  • [49] Grid Harmonics Suppression Scheme for LCL-Type Grid-Connected Inverters Based on Output Admittance Revision
    Wu, Xiaojie
    Li, Xiaoqiang
    Yuan, Xibo
    Geng, Yiwen
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (02) : 411 - 421
  • [50] A Method for Improving Adaptability of LCL-Type Inverter to Weak Grid
    Wang, Shilei
    Tian, Yanjun
    Wang, Yi
    Chen, Bo
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,