An Improved Design of Current Controller for LCL-Type Grid-Connected Converter to Reduce Negative Effect of PLL in Weak Grid

被引:151
作者
Zhou, Shiying [1 ]
Zou, Xudong [1 ]
Zhu, Donghai [1 ]
Tong, Li [2 ]
Zhao, Yingying [3 ]
Kang, Yong [1 ]
Yuan, Xiaoming [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Zhejiang Elect Power Corp Res Inst, Hangzhou 310014, Zhejiang, Peoples R China
[3] State Grid Anhui Econ Res Inst, Hefei 230000, Anhui, Peoples R China
关键词
Current controller; grid-connected converter; phase-locked loop (PLL); small-signal impedance model; weak grid; CONTROL STRATEGY; VECTOR CONTROL; VOLTAGE; STABILITY; INVERTER; FILTERS;
D O I
10.1109/JESTPE.2017.2780918
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For three-phase LCL-type grid-connected converter, when it is attached to weak grid, current control interacts with phase-locked loop (PLL) via point of common coupling voltage. Consequently, PLL dynamic might deteriorate grid current control and even result in system instability. However, the conventional design method of current controller neglects the impact of PLL, and therefore, it is hard for the current controller to mitigate the negative effect of PLL. In this paper, an improved design of current controller, i.e., proportional-integral controller and capacitor-current-feedback active damping, is proposed to reduce the negative effect of PLL on current control. First, a small-signal impedance model is developed to analyze the impact of PLL on current control. Then, the effect of current controller parameters on the converter output impedance is analyzed, and a design guideline to improve the current controller parameters is presented. With the improved parameters, in precondition of satisfying system stability margin under both stiff and weak grid, the negative effect of PLL on current control can be effectively mitigated without employing additional control strategies. Furthermore, the current control has a strong robustness against wide-range variation of grid impedance. Finally, the experiment demonstrates the effectiveness of the proposed design method.
引用
收藏
页码:648 / 663
页数:16
相关论文
共 50 条
  • [1] Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
    Zhu, Donghai
    Zhou, Shiying
    Zou, Xudong
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (05) : 4715 - 4727
  • [2] Analysis and Design of PLL Less Current Control for Weak Grid-Tied LCL-Type Voltage Source Converter
    Maganti, Suresh
    Padhy, Narayana Prasad
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (04) : 4026 - 4040
  • [3] Stability Analysis of LCL-type Grid-connected Inverter in Weak Grid Systems
    Chen, Xin
    Gong, Chun Yin
    Wang, Hui Zhen
    Cheng, Lin
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [4] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 2126 - 2137
  • [5] A Current Decoupling Control Scheme for LCL-Type Single-Phase Grid-Connected Converter
    Tang, Xiongmin
    Chen, Weizheng
    Zhang, Miao
    IEEE ACCESS, 2020, 8 : 37756 - 37765
  • [6] Indirect Grid Current Control of LCL Filter based Grid-Connected Converter
    Mukherjee, Subhajyoti
    Shamsi, Pourya
    Ferdowsi, Mehdi
    Kimball, Jonathan
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 3024 - 3031
  • [7] Resonant feedforward control strategy for LCL-type grid-connected inverters in weak grid condition
    Xu F.
    Tang Y.
    Gu W.
    2016, Chinese Society for Electrical Engineering (36): : 4970 - 4979
  • [8] High Robustness Weighted Average Current Control for LCL-type Grid-connected Inverter in a Weak Grid
    Zhu K.
    Sun P.
    Wang L.
    Zhou L.
    Xue T.
    Du X.
    Li Z.
    1600, Chinese Society for Electrical Engineering (40): : 3592 - 3601
  • [9] Phase-Locked Loop Small-Signal Disturbance Compensation Control for Three-Phase LCL-Type Grid-Connected Converter under Weak Grid
    Zhu, Donghai
    Zhou, Shiying
    Zou, Xudong
    Kang, Yong
    Zou, Kaifeng
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 3108 - 3112
  • [10] Improved Controller of LCL-Type Grid-connected Inverter System based on Active-Damping
    Tian, Peng
    Li, Zetao
    Hao, Zhenghang
    PROCEEDINGS OF 2018 10TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION AND CONTROL (ICMIC), 2018,