Analytical performance evaluation of thyroid-stimulating hormone receptor antibody (TRAb) immunoassays

被引:4
|
作者
Higgins, V [1 ]
Patel, K. [2 ]
Kulasingam, V [1 ,2 ]
Beriault, D. R. [1 ,3 ]
Rutledge, A. C. [4 ,5 ,6 ]
Selvaratnam, R. [1 ,2 ]
机构
[1] Univ Toronto, Dept Lab Med & Pathobiol, Toronto, ON, Canada
[2] Univ Hlth Network, Div Clin Biochem, Lab Med Program, Toronto, ON, Canada
[3] Unity Hlth Toronto, Dept Lab Med, Toronto, ON, Canada
[4] London Hlth Sci Ctr, Dept Pathol & Lab Med, London, ON, Canada
[5] St Josephs Hlth Care London, London, ON, Canada
[6] Western Univ, Dept Pathol & Lab Med, London, ON, Canada
关键词
Autoimmunity; TRACE; Graves' disease; TSH-receptor antibody; TRAb; Thyroid stimulating antibody; Roche cobas; Thermo Scientific Kryptor; BRAHMS; Biotin; GRAVES-DISEASE; DIAGNOSIS;
D O I
10.1016/j.clinbiochem.2020.08.007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Thyroid-stimulating hormone receptor (TSHR)-activating autoantibodies stimulate thyroid growth and hormone synthesis/secretion, causing hyperthyroidism of Graves' disease (GD). TRAb measurement helps diagnose GD and is an important first test in evaluating hyperthyroidism according to the recent American Thyroid Association guidelines. We compared the performance of the BRAHMS TRAK Kryptor (Thermo Scientific) and Roche cobas TRAb immunoassays for use in GD. Method: Method comparison (n = 40) and clinical agreement were assessed between the Kryptor, cobas e411, and cobas e601. The analytical performance of Kryptor and cobas e411 were assessed for within- and between-day imprecision across 20 days, linearity, functional assay sensitivity (FAS), dilution recovery, and cut-off verification. Results: The Kryptor, e411, and e601 TRAb immunoassays correlated well (r > 0.95, overall percent agreement = 0.95, Cohen's kappa = 0.90). With a total allowable error of 20%, percent bias was within 13%, which was minimally negative at< 20 IU/L, but highly positive (33%-34%) > 20 IU/L. The Kryptor, but not e411, was linear across the claimed analytical measuring range (AMR). The claimed functional assay sensitivity (FAS), which was close to the clinical GD cut-off 1.8 IU/L, was verified for Kryptor and e411. Conclusion: Overall, our evaluation demonstrates acceptable comparability between TRAb immunoassays with in-house imprecision up to 13% and 10% on Kryptor and e411, respectively. While Roche has preferable calibration frequency and on-board reagent stability, both platforms demonstrate acceptable imprecision using patient samples at their claimed FAS, which is important for GD diagnosis. Diluted results (using a negative patient pool as diluent) exhibits proportional positive bias on the Kryptor relative to the Roche methods.
引用
收藏
页码:56 / 60
页数:5
相关论文
共 50 条
  • [21] Evaluation of the diagnostic performance of thyroid-stimulating immunoglobulin and thyrotropin receptor antibodies for Graves' disease
    Xu, Shiji
    Shao, Wenqi
    Wu, Qun
    Zhu, Jing
    Pan, Baishen
    Wang, Beili
    Guo, Wei
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2023, 37 (08)
  • [22] Mechanism of action of a nanomolar potent, allosteric antagonist of the thyroid-stimulating hormone receptor
    van Koppen, Chris J.
    de Gooyer, Marcel E.
    Karstens, Willem-Jan
    Plate, Ralf
    Conti, Paolo G. M.
    van Achterberg, Tanja A. E.
    van Amstel, Monique G. A.
    Brands, Jolanda H. G. M.
    Wat, Jesse
    Berg, Rob J. W.
    Lane, J. Robert D.
    Miltenburg, Andre M. M.
    Timmers, C. Marco
    BRITISH JOURNAL OF PHARMACOLOGY, 2012, 165 (07) : 2314 - 2324
  • [23] A case of pretibial myxedema associated with hypothyroidism and thyroid-stimulating hormone receptor antibodies
    Oh, Sang Yong
    Cho, Han Kyoung
    Jung, Yoon Yang
    Lee, Min-Kyung
    DERMATOLOGICA SINICA, 2019, 37 (03) : 166 - 169
  • [24] Autonomous Adenomas Caused by Somatic Mutations of the Thyroid-Stimulating Hormone Receptor in Children
    Grob, Francisca
    Deladoey, Johnny
    Legault, Laurent
    Spigelblatt, Linda
    Fournier, Anne
    Vassart, Gilbert
    Van Vliet, Guy
    HORMONE RESEARCH IN PAEDIATRICS, 2014, 81 (02): : 73 - 79
  • [25] Effects of Thyroid-stimulating Hormone Receptor Autoantibody on Retinal and Choroidal Vessels in Thyroid Eye Disease
    Park, Ji Woong
    Kim, Yu Cheol
    Lee, Dong Cheol
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (10): : 1121 - 1128
  • [26] The role of thyroid-stimulating hormone and thyroglobulin antibody in abnormally invasive placenta
    Ozler, Sibel
    Oztas, Efser
    Kebapcilar, Aysegul
    Caglar, Ali Turhan
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (25) : 5108 - 5115
  • [27] Development and basic performance verification of a rapid homogeneous bioassay for agonistic antibodies against the thyroid-stimulating hormone receptor
    Hoshina, Motoki
    Ojima, Shiomi
    Kawasaki, Atsushi
    Doi, Kosuke
    Ohta, Satoshi
    Inoue, Asuka
    Murayama, Hiroshi
    JOURNAL OF IMMUNOLOGICAL METHODS, 2024, 528
  • [28] Serum thyroid-stimulating hormone receptor antibody levels and thyroid dysfunction after hysterosalpingography: a case-control study
    So, Shuhei
    Hashimoto, Koshi
    Mori, Masatomo
    Endo, Shigeki
    Yamaguchi, Wakasa
    Miyano, Naomi
    Murabayashi, Nao
    Tawara, Fumiko
    GYNECOLOGICAL ENDOCRINOLOGY, 2021, 37 (10) : 898 - 901
  • [29] Early changes in thyroid-stimulating antibody activity following radioiodine therapy
    Syed, AA
    Evans, C
    Ludgate, M
    Lazarus, JH
    MEDICAL PRINCIPLES AND PRACTICE, 2003, 12 (04) : 266 - 268
  • [30] Analytical and clinical performance of newly developed immunoassay for detecting thyroid-stimulating immunoglobulin, the Immulite TSI assay
    Kim, Jin Ju
    Jeong, Soon-Ho
    Kim, Byungkwang
    Kim, Dokyun
    Jeong, Seok Hoon
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2019, 79 (06) : 443 - 448