Slot Partial Discharge Characteristics Under Electrothermal Aging of 10 kV Motor Stator Windings

被引:0
|
作者
Kang, Ailiang [1 ]
Tian, Muqin [1 ]
Song, Jiancheng [1 ]
Lin, Lingyan [1 ]
Lei, Zhipeng [1 ]
机构
[1] Taiyuan Univ Technol, Natl & Prov Joint Engn Lab Min Intelligent Elect, Shanxi Key Lab Min Elect Equipment & Intelligent, Taiyuan, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical and thermal stresses have an important role in the process of slot partial discharges (PDs) for 10 kV motor stator windings. In this paper, an accelerated electrothermal aging system has been carried out to conduct the research of the slot discharge characteristics in 10 kV stator windings, such as slot PD patterns, the NQS and the changes of the insulation surface and stator core surface at the end of aging. During the experiment, at triple the rated line-to-ground voltage of 6 kV, two groups of windings were aged for 30 days under different temperatures. The result confirms that electro-thermal aging can promote the slot discharge to a certain extent and lead to the surface degradation. In addition, the study can provide a judging basis for on-line monitoring and fault diagnosis of HV motors because all of the PD patterns are collected under rated voltage.
引用
收藏
页码:517 / 520
页数:4
相关论文
共 50 条
  • [21] Effects of Frequency and Temperature on Partial Discharge Characterization of Stator Windings
    Kantar, Emre
    Eberg, Espen
    Hvidsten, Sverre
    2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 369 - 373
  • [22] Propagation of partial discharge signals in stator windings of turbine generators
    Pemen, AJM
    van der Laan, PCT
    de Leeuw, W
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) : 155 - 161
  • [23] Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings
    Kim, Hee-Dong
    Kong, Tae-Sik
    Lee, Sang-Kil
    Kim, Beom-Soo
    Kim, Doo-Young
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2015, 10 (03) : 1086 - 1092
  • [24] Partial discharge characteristics of 10 kV XLPE cable joints under oscillating voltage
    State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing
    400030, China
    不详
    510410, China
    Gaodianya Jishu, 4 (1068-1074):
  • [25] Judgement criterion of insulation deterioration in 4.16 kV and 6.6 kV motor stator windings
    Kim, Hee-Dong
    Transactions of the Korean Institute of Electrical Engineers, 2009, 58 (04): : 788 - 794
  • [26] The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings
    Yang, Sang-Hyun
    Park, Noh-Joon
    Park, Dae-Hee
    Kim, Hee-Dong
    Lim, Kwang-Jin
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2009, 10 (05) : 173 - 176
  • [27] Monitoring partial discharges on 4 kV motor windings
    Tetrault, S
    Stone, GC
    Sedding, HG
    INDUSTRY APPLICATIONS SOCIETY 44TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 1997, : 159 - 165
  • [28] Analysis of Insulation Breakdown in Slot End of Stator Windings of High Voltage Motor
    Yoon, Hoyeol
    Bae, Youngchul
    Transactions of the Korean Institute of Electrical Engineers, 2024, 73 (08): : 1461 - 1465
  • [29] Continuous on-line partial discharge monitoring of generator stator windings
    Lloyd, BA
    Campbell, SR
    Stone, GC
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) : 1131 - 1137
  • [30] Surface partial discharge in hydrogenerator stator windings: Causes, symptoms, and remedies
    Dehlinger, Nicolas
    Stone, Greg
    IEEE ELECTRICAL INSULATION MAGAZINE, 2020, 36 (03) : 7 - 18