Coatings for biodegradable magnesium-based supports for therapy of vascular disease: A general view

被引:64
作者
Echeverry-Rendon, Monica [1 ,2 ,3 ]
Allain, Jean Paul [4 ]
Robledo, Sara M. [2 ]
Echeverria, Felix [1 ]
Harmsen, Martin C. [3 ]
机构
[1] Univ Antioquia, Ctr Invest Innovac & Desarrollo Mat CIDEMAT, Fac Ingn, Calle 70 52-21, Medellin, Colombia
[2] Univ Antioquia, PECET, Inst Invest Med, Fac Med, Calle 70 52-21, Medellin, Colombia
[3] Univ Med Ctr Groningen, Dept Pathol & Med Biol, Hanzepl 1,EA11, NL-9713 GZ Groningen, Netherlands
[4] Univ Illinois, Beckman Inst, Micro & Nanotechnol Lab, Dept Nucl Plasma & Radiol Engn, Urbana, IL 61801 USA
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2019年 / 102卷
关键词
Stent; Cardiovascular disease; Magnesium; Biodegradation; Biocorrosion; Surface modification; MICRO-ARC OXIDATION; IN-VITRO DEGRADATION; DRUG-ELUTING STENTS; PLASMA ELECTROLYTIC OXIDATION; IMPROVED CORROSION-RESISTANCE; ABSORBABLE METAL SCAFFOLD; HIGH-PURITY MAGNESIUM; ION-BEAM IRRADIATION; Y-ND ALLOY; MG ALLOY;
D O I
10.1016/j.msec.2019.04.032
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Metal stents are used as base material for fabrication of medical devices to support and improve the quality of life of patients with cardiovascular diseases such as arterial stenoses. Permanently present implants may induce responses that resemble adverse wound healing that compromise tissue function. A similar process namely restenosis, frequently may occur after the use of this kind of implants. However, the use of non-permanent, resorbable stents are a promising option to avoid this problem. The advantage of these implants is that they can degraded upon vascular repair. The most common metal used for this application, is magnesium (Mg) which is an interesting material due its biological properties and because it is an essential element for human life. However, Mg-based resorbable biomaterial have some restrictions in clinical applications because its corrosion resistance, and mechanical properties. As solutions of this problem, the material can be modified in its composition (Mg-based alloys) or by surface treatments. This review shows and discusses recent challenges in the improvement of Mg-based biomaterials to be used to treat vascular disease and novel approaches at design-based biomaterials engineering of the same. Design-based methodologies are introduced and discussed in the context of balancing multi-functional properties against adaptation to the complex extreme in vivo environment. Traditional alloying approaches of Mg-based biomaterials are also discussed in the context of corrosion resistance controlled by surface modification strategies including conversion techniques: physicochemical or electrochemical transformation such as anodization, plasma and electrophoretic deposition.
引用
收藏
页码:150 / 163
页数:14
相关论文
共 202 条
[1]   The in vivo and in vitro corrosion of high-purity magnesium and magnesium alloys WZ21 and AZ91 [J].
Abidin, Nor Ishida Zainal ;
Rolfe, Barbara ;
Owen, Helen ;
Malisano, Julian ;
Martin, Darren ;
Hofstetter, Joelle ;
Uggowitzer, Peter J. ;
Atrens, Andrej .
CORROSION SCIENCE, 2013, 75 :354-366
[2]   Biodegradable Metals [J].
Aghion, Eli .
METALS, 2018, 8 (10)
[3]  
Aguilar F, 2009, EFSA, V1132, P1
[4]  
Akin I, 2011, HERZ, V36, P190, DOI 10.1007/s00059-011-3458-z
[5]  
Allain JP., 2014, NANOPATTERNING NANOS, P41, DOI [10.1201/b17161, DOI 10.1201/B17161-2]
[6]   Corrosion behaviour of magnesium alloys coated with TiN by cathodic arc deposition in NaCl and Na2SO4solutions [J].
Altun, Hikmet ;
Sinici, Hakan .
MATERIALS CHARACTERIZATION, 2008, 59 (03) :266-270
[7]   The effect of PVD coatings on the wear behaviour of magnesium alloys [J].
Altun, Hikmet ;
Sen, Sadri .
MATERIALS CHARACTERIZATION, 2007, 58 (10) :917-921
[8]   Corrosion behaviour of AZ31 magnesium alloy with different grain sizes in simulated biological fluids [J].
Alvarez-Lopez, M. ;
Dolores Pereda, Maria ;
del Valle, J. A. ;
Fernandez-Lorenzo, M. ;
Garcia-Alonso, M. C. ;
Ruano, O. A. ;
Escudero, M. L. .
ACTA BIOMATERIALIA, 2010, 6 (05) :1763-1771
[9]   Foreign body reaction to biomaterials [J].
Anderson, James M. ;
Rodriguez, Analiz ;
Chang, David T. .
SEMINARS IN IMMUNOLOGY, 2008, 20 (02) :86-100
[10]   Mechanical behavior of polymer-based vs. metallic-based bioresorbable stents [J].
Ang, Hui Ying ;
Huang, Ying Ying ;
Lim, Soo Teik ;
Wong, Philip ;
Joner, Michael ;
Foin, Nicolas .
JOURNAL OF THORACIC DISEASE, 2017, 9 :S923-S934