In-port derivatization coupled to different extraction techniques for the determination of allkylphenols in environmental water samples

被引:17
作者
Cavalheiro, J. [1 ,2 ]
Monperrus, M. [2 ]
Amouroux, D. [2 ]
Preud'Homme, H. [2 ]
Prieto, A. [1 ]
Zuloaga, O. [1 ]
机构
[1] Univ Basque Country, Fac Sci & Technol, Dept Analyt Chem, Bilbao 48080, Spain
[2] Univ Pau & Pays Adour, CNRS UMR 5254, Inst Pluridisciplinaire Rech Environm & Mat, Lab Chim Analyt Bioinorgan & Environm, F-64053 Pau 9, France
关键词
In-port derivatization; Large volume injection; Alkylphenols; Water samples; Different extraction techniques; BAR SORPTIVE EXTRACTION; ASSISTED SOLVENT-EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; RESTRICTED-ACCESS MATERIALS; TANDEM MASS-SPECTROMETRY; SILICONE ROD EXTRACTION; STIR-BAR; ORGANIC POLLUTANTS; ALKYLPHENOL POLYETHOXYLATES; ESTROGENIC COMPOUNDS;
D O I
10.1016/j.chroma.2014.03.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Large volume injection (LVI)-in port silylation coupled to gas chromatography-mass spectrometry (GC-MS) for the determination of allcylphenols (APs) in water samples applying four different extraction approaches was evaluated. Among the variables studied for in-port derivatization, vent time, cryofocusing temperature and the ratio solvent volume/N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) volume were optimized using an experimental design approach. Regarding the extraction techniques, different approaches previously optimized in the research group were tested. On the one hand different polymeric materials were tested: silicon rod (SR), polyethersulfone (PES) and polydimethylsiloxane (PDMS), the latter in the stir-bar sorptive extraction format (SBSE-PDMS). PES was chosen among the polymeric materials due to the higher recoveries (compared with SR) and lower price (compared to PDMS in the stir-bar sorptive extraction, SBSE-PDMS). Both MASE and PES protocols were selected at this point for further method validation and application to real samples. Finally, the developed methods were validated and applied to the determination of target analytes in various aqueous environmental matrices, including estuarine water and wastewater. Acceptable repeatability in the case of MASE (5-17%) and PES (7-21%) procedures and method detection limits (MDLs, 5-123 and 28-328 ng L-1 for PES and MASE, respectively) were obtained for most analytes. In terms of apparent recoveries in the presence of matrix, estuarine and effluent samples showed no significant matrix effect (apparent recoveries in the 73-121% for PES and 74-128% for MASE), while a stronger matrix effect was observed for influent wastewater samples (98-132% for PES and 65-156% for MASE). Both MASE and PES extractions combined with LVI-in-port derivatization-GC-MS were applied to the determination of APs in the estuary of Bilbao (Gulf of Biscay, Spain). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 61 条
[1]   Estrogenic metabolites of alkylphenol polyethoxylates in secondary sewage effluents and rivers [J].
Ahel, M ;
Molnar, E ;
Ibric, S ;
Giger, W .
WATER SCIENCE AND TECHNOLOGY, 2000, 42 (7-8) :15-22
[2]  
Belardi R.P., 1989, CAN J WATER RES POLL, V23, P179
[3]   Review of the environmental occurrence of alkylphenols and alkylphenol ethoxylates [J].
Bennie, DT .
WATER QUALITY RESEARCH JOURNAL OF CANADA, 1999, 34 (01) :79-122
[4]   In-port derivatization after sorptive extractions [J].
Bizkarguenaga, E. ;
Iparragirre, A. ;
Navarro, P. ;
Olivares, M. ;
Prieto, A. ;
Vallejo, A. ;
Zuloaga, O. .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1296 :36-46
[5]  
Blanco-Zubiaguirre L, 2014, ENV SCI POLLUT RES
[6]   A new silylation reagent dimethyl(3,3,3-trifluoropropyl)silyldiethylamine for the analysis of estrogenic compounds by gas chromatography-mass spectrometry [J].
Caban, Magda ;
Czerwicka, Malgorzata ;
Lukaszewicz, Paulina ;
Migowska, Natalia ;
Stepnowski, Piotr ;
Kwiatkowski, Marek ;
Kumirska, Jolanta .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1301 :215-224
[7]   Polyethersulfone solid-phase microextraction followed by liquid chromatography quadrupole time-of-flight mass spectrometry for benzotriazoles determination in water samples [J].
Casado, J. ;
Rodriguez, I. ;
Ramil, M. ;
Cela, R. .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1299 :40-47
[8]   Selective extraction of triazine herbicides based on a combination of membrane assisted solvent extraction and molecularly imprinted solid phase extraction [J].
Chimuka, Luke ;
van Pinxteren, Manuela ;
Billing, Johan ;
Yilmaz, Ecevit ;
Jonsson, Jan Ake .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (05) :647-653
[9]   A Critical Review of the Formation of Mono- and Dicarboxylated Metabolic Intermediates of Alkylphenol Polyethoxylates during Wastewater Treatment and Their Environmental Significance [J].
Chiu, T. Y. ;
Paterakis, N. ;
Cartmell, E. ;
Scrimshaw, M. D. ;
Lester, J. N. .
CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2010, 40 (03) :199-238
[10]   Stir bar sorptive extraction for trace analysis [J].
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :54-69