Development and validation of liquid chromatography-tandem mass spectrometry method for quantification of a potential anticancer triterpene saponin from seeds of Nigella glandulifera in rat plasma: Application to a pharmacokinetic study

被引:8
|
作者
Hu, Xingjiang [1 ]
Liu, Xiaobao [2 ]
Gong, Minghua [3 ]
Luan, Ming [3 ]
Zheng, Yunliang [1 ]
Wu, Guolan [1 ]
Shentu, Jianzhong [1 ]
Zhang, Lin [3 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 1, Res Ctr Clin Pharm, Hangzhou 310003, Zhejiang, Peoples R China
[2] Cent S Univ, Xiangya Med Sch, Affiliated Tumor Hosp, Hunan Prov Tumor Hosp,Inst Clin Pharmaceut Res, Changsha 410013, Hunan, Peoples R China
[3] Zhejiang Univ, Dept Biomed Engn, Hangzhou 310027, Zhejiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 967卷
基金
中国国家自然科学基金;
关键词
Nigella A; LC-MS/MS; Pharmacokinetics; Rat plasma; ALPHA-HEDERIN; SATIVA L; THYMOQUINONE; CONSTITUENTS; BLACKSEED;
D O I
10.1016/j.jchromb.2014.07.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nigella glandulifera Freyn et Sit is a folk medicinal plant, whose seeds show significant anticancer activities attributed to triterpene saponins and volatile oil. In this study, an in vitro cytotoxicity assay demonstrated that Nigella A, the major component of triterpene saponins extracted from N. glandulifera, exhibited growth inhibition in the human lung carcinoma A-549 cell line. Due to this potential activity, a reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify Nigella A in rat plasma for a pharmacokinetic study was developed. Nigella A and pravastatin, as internal standard (IS), were extracted from rat plasma using acetonitrile to precipitate protein. Separation was performed on an Agilent Zorbax SB-Aq (3.0 x 150 mm, 3.5 mu m) column using a gradient elution method with acetonitrile-0.1% formic acid in water at a flow rate of 0.35 mL/min. Detection was performed using an electrospray ionization in a negative ion multiple reaction monitoring mode. The deprotonated precursor to product ion transitions monitored for Nigella A and IS was at m/z 1352.7 -> 882.6 and m/z 423.1 -> 321.0, respectively. The linear range was 0.240-120 mu g/mL with a square regression coefficient (r=0.9996). The intra-day and inter-day precision was less than 6.93%. The simple extraction procedure provided recovery ranged from 92.32 to 95.44% for both analyte and IS. The method was proved to be reliable, precise, and accurate, and was successfully applied to a pharmacokinetic study of Nigella A in rats after i.v. administration via the tail vein at doses of 10, 20, and 30 mg/kg. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 161
页数:6
相关论文
共 50 条
  • [31] Determination of Ferulic Acid in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry Method: Application to a Pharmacokinetic Study
    Zhang, Tianhong
    Yang, Xiuli
    Zhang, Peng
    Zhu, Meng
    He, Zhonggui
    Bi, Kaishun
    ANALYTICAL LETTERS, 2009, 42 (14) : 2157 - 2169
  • [32] Quantification of pinosylvin in rat plasma by liquid chromatography-tandem mass spectrometry: Application to a pre-clinical pharmacokinetic study
    Yeo, Samuel Chao Ming
    Luo, Wenxia
    Wu, Jinzhu
    Ho, Paul C.
    Lin, Hai-Shu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 68 - 74
  • [33] Development and validation of a rapid, sensitive liquid chromatography-tandem mass spectrometry method using electrospray ionization for quantitation of centchroman in rat plasma and its application to preclinical pharmacokinetic study
    Singh, Sheelendra Pratap
    Singh, Ravi Shankar Prasad
    Wahajuddin
    Jain, Girish Kumar
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 1 - 7
  • [34] Development and validation of a liquid chromatography-tandem mass spectrometry method for simultaneous quantification of eight Xiakucao Oral liquid-related compounds in rat plasma and its application in pharmacokinetic study
    Jin, Jingyi
    Xu, Xiaoqing
    Wang, Xinwei
    Chen, Biao
    Miao, Yingying
    Chen, Zhongguo
    Yan, Dongming
    Qiu, Furong
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (09)
  • [35] Determination of larotaxel and its metabolites in rat plasma by liquid chromatography-tandem mass spectrometry: Application for a pharmacokinetic study
    Liu, Zhenzhen
    Zhang, Lunhui
    Ju, Ping
    Hou, Pengyi
    Zhang, Yuanyuan
    Tang, Xing
    Bi, Kaishun
    Chen, Xiaohui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 132 - 138
  • [36] Determination of liraglutide in rat plasma by a selective liquid chromatography-tandem mass spectrometry method: Application to a pharmacokinetics study
    Dong, Shiqi
    Gu, Yuan
    Wei, Guangli
    Si, Duanyun
    Liu, Changxiao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1091 : 29 - 35
  • [37] Development and full validation of a liquid chromatography-tandem mass spectrometry method for determination of carbinoxamine in beagle plasma and its application to a pharmacokinetic study
    Li, Pei
    Xiao, Jie
    Liu, Jing
    Liu, Ran
    Bi, Kaishun
    Li, Qing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1093 : 183 - 189
  • [38] Determination of genkwanin in rat plasma by liquid chromatography-tandem mass spectrometry: Application to a bioavailability study
    Song, Yanqing
    Zhang, Sixi
    Liu, Hong
    Jin, Xiangqun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 84 : 129 - 134
  • [39] A liquid chromatography-tandem mass spectrometry method for the quantification of PAC-1 in rat plasma
    Fang, Li-Na
    Chen, Xiao-Hui
    Wang, Qiu-Di
    Zhang, Di
    Zhao, Juan-Juan
    Long, Zhi-Min
    Gong, Ping
    Bi, Kai-Shun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 225 - 229
  • [40] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of scutellarin in human plasma: Application to a pharmacokinetic study
    Yulan, S
    Fang, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (01): : 1 - 5