Studies on application of vertical axis hydro turbine for sustainable power generation in irrigation channels with different bed slopes

被引:24
作者
Shashikumar, C. M. [1 ]
Honnasiddaiah, Ramesh [2 ]
Hindasageri, Vijaykumar [1 ]
Madav, Vasudeva [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Surathkal 575025, India
[2] Natl Inst Technol Karnataka, Dept Water Resources & Ocean Engn, Surathkal 575025, India
关键词
Coefficient of power; Coefficient of torque; Tip speed ratio; Hydropower generation; Bed slope inclination; SAVONIUS HYDROKINETIC TURBINE; PERFORMANCE; DESIGN; VELOCITY;
D O I
10.1016/j.renene.2020.09.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present work is carried out to study the performance of a Savonius rotor for small-scale hydropower generation. It has been observed that some of the irrigation channels available in the rural areas are having enough bed slope to generate kinetic energy, which can be harnessed through a Savonius rotor. An in-house fabricated scale-down model of the Savonius rotor is tested at an inclination of the re-circulating indoor multipurpose tilting flume at 0 degrees, 0.5 degrees, 1.0 degrees, 1.5 degrees and 2.0 degrees to determine performance under controlled conditions. It is observed that at the tip speed ratio of 0.92 and channel inclination of 0.5 degrees compared to 0 degrees inclination, the coefficient of power and coefficient of torque improved to 40% and 10%, respectively. Furthermore, it is found that the torque and power developed by the turbine are maximum at a bed slope of 2.0 degrees owing to the maximum available energy. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:845 / 857
页数:13
相关论文
共 38 条
[1]   A review on the performance of Savonius wind turbines [J].
Akwa, Joao Vicente ;
Vielmo, Horacio Antonio ;
Petry, Adriane Prisco .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) :3054-3064
[2]   WIND-TUNNEL TESTS ON A SAVONIUS ROTOR [J].
ALEXANDER, AJ ;
HOLOWNIA, BP .
JOURNAL OF INDUSTRIAL AERODYNAMICS, 1978, 3 (04) :343-351
[3]  
Batten WMJ, 2011, P 34 IAHR WORLD C BR, P2364
[4]   Power measurement of hydrokinetic turbines with free-surface and blockage effect [J].
Birjandi, Amir Hossein ;
Bibeau, Eric Louis ;
Chatoorgoon, Vijay ;
Kumar, Anurag .
OCEAN ENGINEERING, 2013, 69 :9-17
[5]  
Cleynen O., 2017, COMPUTATIONAL EXPT M, V115, P55, DOI 10.2495/MPF170071.
[6]   Performance study of ducted nozzle. Savonius water turbine, comparison with conventional Savonius turbine [J].
Elbatran, A. H. ;
Ahmed, Yasser M. ;
Shehata, Ahmed S. .
ENERGY, 2017, 134 :566-584
[7]   Study on the Interaction between Two Hydrokinetic Savonius Turbines [J].
Golecha, Kailash ;
Eldho, T. I. ;
Prabhu, S. V. .
INTERNATIONAL JOURNAL OF ROTATING MACHINERY, 2012, 2012
[8]   Influence of the deflector plate on the performance of modified Savonius water turbine [J].
Golecha, Kailash ;
Eldho, T. I. ;
Prabhu, S. V. .
APPLIED ENERGY, 2011, 88 (09) :3207-3217
[9]  
Gunawan B., 2017, MAR, DOI [10.1044/leader.ppl.22032017.18, DOI 10.1044/LEADER.PPL.22032017.18]
[10]   Experimental and numerical study of a flapping-blade vertical-axis hydrokinetic turbine under free surface deformation and blockage effects [J].
Hashemi, S. M. ;
Moghimi, M. ;
Derakhshan, S. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2020, 17 (08) :3633-3650