摘要
Adaptive optics optical coherence tomography (AO-OCT) is a highly sensitive and noninvasive method for three dimensional imaging of the microscopic retina. Like all in vivo retinal imaging techniques, however, it suffers the effects of involuntary eye movements that occur even under normal fixation. In this study we investigated dynamic retinal tracking to measure and correct eye motion at KHz rates for AO-OCT imaging. A customized retina tracking module was integrated into the sample arm of the 2nd-generation Indiana AO-OCT system and images were acquired on three subjects. Analyses were developed based on temporal amplitude and spatial power spectra in conjunction with strip-wise registration to independently measure AO-OCT tracking performance. After optimization of the tracker parameters, the system was found to correct eye movements up to 100 Hz and reduce residual motion to 10 m root mean square. Between session precision was 33 m. Performance was limited by tracker-generated noise at high temporal frequencies. (C) 2014 Optical Society of America
引用
收藏
页码:2262 / 2284
页数:23
相关论文
共 40 条
  • [1] Swept source optical coherence microscopy using a 1310 nm VCSEL light source
    Ahsen, Osman O.
    Tao, Yuankai K.
    Potsaid, Benjamin M.
    Sheikine, Yuri
    Jiang, James
    Grulkowski, Ireneusz
    Tsai, Tsung-Han
    Jayaraman, Vijaysekhar
    Kraus, Martin F.
    Connolly, James L.
    Hornegger, Joachim
    Cable, Alex
    Fujimoto, James G.
    [J]. OPTICS EXPRESS, 2013, 21 (15): : 18021 - 18033
  • [2] High speed spectral domain optical coherence tomography for retinal imaging at 500,000 A-lines per second
    An, Lin
    Li, Peng
    Shen, Tueng T.
    Wang, Ruikang
    [J]. BIOMEDICAL OPTICS EXPRESS, 2011, 2 (10): : 2770 - 2783
  • [3] Real-time eye motion correction in phase-resolved OCT angiography with tracking SLO
    Braaf, Boy
    Vienola, Kari V.
    Sheehy, Christy K.
    Yang, Qiang
    Vermeer, Koenraad A.
    Tiruveedhula, Pavan
    Arathorn, David W.
    Roorda, Austin
    de Boer, Johannes F.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2013, 4 (01): : 51 - 65
  • [4] Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope
    Burns, Stephen A.
    Tumbar, Remy
    Elsner, Ann E.
    Ferguson, Daniel
    Hammer, Daniel X.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) : 1313 - 1326
  • [5] Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources
    Cense, Barry
    Koperda, Eric
    Brown, Jeffrey M.
    Kocaoglu, Omer P.
    Gao, Weihua
    Jonnal, Ravi S.
    Miller, Donald T.
    [J]. OPTICS EXPRESS, 2009, 17 (05): : 4095 - 4111
  • [6] Dainty J.C., 1984, Laser Speckle and Related Phenomena
  • [7] Ezenman M., 1985, VISION RES, V25, P1635
  • [8] Ferguson R. D., OPT EXPRESS, V12, P5198
  • [9] Ferguson R. D., 1996, US Patent, Patent No. 5767941
  • [10] Adaptive optics scanning laser ophthalmoscope with integrated wide-field retinal imaging and tracking
    Ferguson, R. Daniel
    Zhong, Zhangyi
    Hammer, Daniel X.
    Mujat, Mircea
    Patel, Ankit H.
    Deng, Cong
    Zou, Weiyao
    Burns, Stephen A.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (11) : A265 - A277