A new strategy for extraction and depuration of pantoprazole in rat plasma: Vortex assisted dispersive micro-solid-phase extraction employing metal organic framework MIL-101(Cr) as sorbent followed by dispersive liquid-liquid microextraction based on solidification of a floating organic droplet

被引:17
|
作者
Cai, Qianqian [1 ]
Zhao, Tianyu [1 ]
Zhang, Lianjun [1 ]
Zhao, Pan [1 ,3 ]
Zhu, Yajie [1 ]
Xu, Haiyan [1 ]
Hou, Xiaohong [2 ]
机构
[1] Shenyang Pharmaceut Univ, Sch Pharm, Shenyang, Liaoning, Peoples R China
[2] Shenyang Pharmaceut Univ, Sch Pharmaceut Engn, Shenyang 110016, Liaoning, Peoples R China
[3] Shandong Univ Tradit Chinese Med, Sch Pharm, Jinan, Shandong, Peoples R China
关键词
Metal organic framework; Dispersive micro-solid-phase extraction; Dispersive liquid-liquid microextraction based on the solidification of a floating organic droplet; Pharmacokinetic; Pantoprazole; MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; WATER; PESTICIDES; SAMPLES;
D O I
10.1016/j.jpba.2019.04.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dispersive micro-solid-phase extraction (DMSPE) combined with dispersive liquid-liquid microextraction based on the solidification of a floating organic droplet (DLLME-SFO) was successfully developed for extraction and depuration of pantoprazole in rat plasma. The remarkable metal organic framework (MOF), MIL-101(Cr) was used as DMSPE adsorbent. The detection of pantoprazole was performed by convenient HPLC-UV. In the extraction of pantoprazole from plasma samples, small molecule compounds, including the target and abundant impurities, were easily admitted into the porous structure of MIL-101 (Cr) material in DMSPE; while, macromolecular compounds were handily excluded from the adsorbent. Next, the depuration process was achieved by removal of small polar impurities in DLLME-SFO. Influential factors were systematically optimized for ideal enrichment and depuration efficiency. Under the optimal conditions, a satisfactory linearity range from the lower limit of quantification (LLOQ 100 ng/L) to 10 000 ng/L with the correlation coefficients (r) of 0.9934 was obtained. The LLOQ was 100 ng/mL and the relative recoveries were >= 73.2 +/- 4.8%. The approving reproducibility, acceptable accuracy, and stability were all within the acceptance limits. This proposed method presented the advantages of environment friendly, low-cost, recyclable, low impurity, and preferable applicability. It could offer a new idea for the pretreatment and pharmacokinetic study of pantoprazole in rat plasma. (C) 2019 Published by Elsevier B.V.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条