Although dual-energy X-ray absorptiometry (DXA) has been widely used for measuring body composition, discrepancies have been reported to exist among results obtained from different instruments. In the course of longitudinal studies lasting for many years, old instruments may be required to be replaced with new ones, necessitating comparison and validation between the values obtained by the old and new instruments. We compared the data obtained by the two fan-beam DXA instruments, QDR-2000 (Hologic, Waltham, MA) and Delphi (Hologic). Body composition was first measured by the Hologic QDR-2000 and next by the Delphi W within 30 days in 99 healthy subjects. Whole-body fat mass (FM), percentage of FM, arm FM, and leg FM measured by the Hologic QDR-2000 were significantly larger than those measured by the Delphi W. Lean tissue mass (LTM), bone mineral content, and bone mineral density of the whole body, trunk FM, arm LTM, and leg LTM measured by the QDR-2000 were significantly smaller than those measured by the Delphi W. After converting the QDR-2000 values by equations developed by multiple regression analysis, they were not significantly different from the corresponding Delphi values. Measurements by the QDR-2000 and the Delphi W were not interchangeable and the conversion equations reduced the discrepancy to a level that enabled direct comparison of the data obtained by the two instruments. However, cautious interpretation is necessary when the conversion equations are applied to other instruments even of the same type or when evaluating data of individual subjects.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 16 条
  • [1] CROSS CALIBRATION OF QDR-2000 AND QDR-1000 DUAL-ENERGY X-RAY DENSITOMETERS FOR BONE-MINERAL AND SOFT-TISSUE MEASUREMENTS
    ABRAHAMSEN, B
    GRAM, J
    HANSEN, TB
    BECKNIELSEN, H
    [J]. BONE, 1995, 16 (03) : 385 - 390
  • [2] Clinical applications of body composition measurements using DXA
    Albanese, CV
    Diessel, E
    Genant, HK
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (02) : 75 - 85
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Bone mineral density and the risk of incident nonspinal fractures in black and white women
    Cauley, JA
    Lui, LY
    Ensrud, KE
    Zmuda, JM
    Stone, KL
    Hochberg, MC
    Cummings, SR
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17): : 2102 - 2108
  • [5] Bone mineral and body composition measurements: Cross-calibration of pencil-beam and fan-beam dual-energy X-ray absorptiometers
    Ellis, KJ
    Shypailo, RJ
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (10) : 1613 - 1618
  • [6] Relation between hormones and body composition, including bone, in prepubertal children
    Garnett, SP
    Högler, W
    Blades, B
    Baur, LA
    Peat, J
    Lee, J
    Cowell, CT
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2004, 80 (04) : 966 - 972
  • [7] Dual-energy x-ray absorptiometry and body composition: Differences between devices and comparison with reference methods
    Genton, L
    Hans, D
    Kyle, UG
    Pichard, C
    [J]. NUTRITION, 2002, 18 (01) : 66 - 70
  • [8] Comparison of bone mineral density and body composition measurements in women obtained from two DXA instruments
    Gillette-Guyonnet, S
    Andrieu, S
    Nourhashemi, F
    Cantet, C
    Grandjean, H
    Vellas, B
    [J]. MECHANISMS OF AGEING AND DEVELOPMENT, 2003, 124 (03) : 317 - 321
  • [9] Excess accumulation of body fat is related to dyslipidemia in normal-weight subjects
    Ito, H
    Nakasuga, K
    Ohshima, A
    Sakai, Y
    Maruyama, T
    Kaji, Y
    Harada, M
    Jingu, S
    Sakamoto, M
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 2004, 28 (02) : 242 - 247
  • [10] Relation between body composition and age in healthy Japanese subjects
    Ito, H
    Ohshima, A
    Ohto, N
    Ogasawara, M
    Tsuzuki, M
    Takao, K
    Hijii, C
    Tanaka, H
    Nishioka, K
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2001, 55 (06) : 462 - 470