An electrochemical immunosensor for digoxin using core-shell gold coated magnetic nanoparticles as labels

被引:71
作者
Ahmadi, Anita [1 ,2 ]
Shirazi, Hanieh [1 ]
Pourbagher, Narges [1 ]
Akbarzadeh, Abolfazl [3 ]
Omidfar, Kobra [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Biosensor Res Ctr, Endocrinol & Metab Mol Cellular Sci Inst, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Res Inst, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] Tabriz Univ Med Sci, Dept Med Chem, Tabriz, Iran
关键词
Core-shell gold coated magnetic nanoparticles; Immunosensor; Digoxin; COLLOIDAL GOLD; SIGNAL AMPLIFICATION; HEART-FAILURE; SERUM DIGOXIN; ANTIBODY; RADIOIMMUNOASSAY; ASSAY;
D O I
10.1007/s11033-013-3014-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A simple, sensitive, and low-cost immunosensor was designed for the detection of digoxin through core-shell gold coated magnetic nanoparticles (Fe3O4-Au-NPs) as an electrochemical label. Having had such a large potential for a variety of applications, Fe3O4-Au-NPs have attracted a considerable attention and are actively investigated recently. Digoxin is a cardiac glycoside which, at high level, can indicate an increased risk of toxicity. This new competitive electrochemical immunosensor was developed based on antigen-antibody reaction employing antigen (Ag) labeled Fe3O4-Au-NPs and PVA modified screen-printed carbon electrode surface in order to detect the serum digoxin. The structures of Fe3O4-Au-NPs were studied by transmission electron microscopy, X-ray diffraction and Fourier transformed infrared spectroscopy. Cyclic voltammetry and differential pulse voltammetry (DPV) were employed to determine the physicochemical and electrochemical properties of immunosensor. DPV was employed for quantitative detection of digoxin in biological samples. The developed immunosensor was capable to detect digoxin in the range from 0.5 to 5 ng mL(-1), with a detection limit as low as 0.05 ng mL(-1). The proposed method represented acceptable reproducibility, stability, and reliability for the rapid detection of digoxin in serum samples.
引用
收藏
页码:1659 / 1668
页数:10
相关论文
共 42 条
[11]   Size-dependent direct electrochemical detection of gold nanoparticles: application in magnetoimmunoassays [J].
de la Escosura-Muniz, Alfredo ;
Parolo, Claudio ;
Maran, Flavio ;
Merkoci, Arben .
NANOSCALE, 2011, 3 (08) :3350-3356
[12]   Preparation and Properties of Various Magnetic Nanoparticles [J].
Drbohlavova, Jana ;
Hrdy, Radim ;
Adam, Vojtech ;
Kizek, Rene ;
Schneeweiss, Oldrich ;
Hubalek, Jaromir .
SENSORS, 2009, 9 (04) :2352-2362
[13]  
Dung D TK., 2009, APCTP-ASEAN Workshop on Advanced Materials Science and Nanotechnology (AMSN08) IOP Publishing Journal of Physics: Conference Series, V187, P012036, DOI [DOI 10.1088/1742-6596/187/1/012036, 10.1088/1742-6596/187/1/012036]
[14]   Salmonella typhi determination using voltammetric amplification of nanoparticles: A highly sensitive strategy for metalloimmunoassay based on a copper-enhanced gold label [J].
Dungchai, Wijitar ;
Siangproh, Weena ;
Chaicumpa, Wanpen ;
Tongtawe, Pongsri ;
Chailapakul, Orawon .
TALANTA, 2008, 77 (02) :727-732
[15]   Permanently oriented antibody immobilization for digoxin determination with a flow-through fluoroimmunosensor [J].
Fernández, P ;
Durand, JS ;
Pérez-Conde, C ;
Paniagua, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (08) :1020-1023
[16]   High-performance liquid chromatography with on-line post-column immunoreaction detection of digoxin and its metabolites based on fluorescence energy transfer in the far-red spectral region [J].
Graefe, KA ;
Tang, Z ;
Karnes, HT .
JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (02) :305-314
[17]   Development of a label-free electrochemical immunosensor based on carbon nanotube for rapid determination of clenbuterol [J].
He, Pingli ;
Wang, Zongyi ;
Zhang, Liying ;
Yang, Wenjun .
FOOD CHEMISTRY, 2009, 112 (03) :707-714
[18]   Pharmacokinetic interaction with digoxin and glucocorticoids in rats detected by radio-immunoassay using a novel specific antiserum [J].
Higashi, Y ;
Ikeda, Y ;
Yamamoto, R ;
Yamashiro, M ;
Fujii, Y .
LIFE SCIENCES, 2005, 77 (09) :1055-1067
[19]   Recent trends in antibody based sensors [J].
Holford, Timothy R. J. ;
Davis, Frank ;
Higson, Seamus P. J. .
BIOSENSORS & BIOELECTRONICS, 2012, 34 (01) :12-24
[20]   Gold nanoparticle-based redox signal enhancement for sensitive detection of human chorionic gonadotropin hormone [J].
Idegami, Koutarou ;
Chikae, Miyuki ;
Kerman, Kagan ;
Nagatani, Naoki ;
Yuhi, Teruko ;
Endo, Tatsuro ;
Tamiya, Eiichi .
ELECTROANALYSIS, 2008, 20 (01) :14-21