Impedance of the eddy-current displacement probe: The transformer model

被引:46
作者
Vyroubal, D [1 ]
机构
[1] Polytech Karlovac, Karlovac 47000, Croatia
关键词
displacement probe; Eddy currents; impedance; transducer linearity; transformer model;
D O I
10.1109/TIM.2003.822705
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new approach to calculation of the impedance of the Eddy-current displacement probe is presented. It is based on the transformer model of the probe-to-target coupling. The usual method of calculating the impedance by solving for the electromagnetic field distribution in the probe and the conductive target involves solution of integral equations. Instead, a simpler approach is possible by modeling the probe-to-target coupling as a loaded transformer, involving only linear ac circuit analysis and elliptic integrals (readily available in MATHCAD, MATLAB, etc.). The model transformer has single primary and multiple secondary windings. The primary winding models the probe coil, while the distributed Eddy current's circulation paths are modeled by multiple secondary windings. The target active area (the Eddy current's carrying area) is divided into concentric rings. Each ring is modeled as a single-turn secondary loaded with the ring impedance. Simulation shows that division of the target active area into a moderate number of rings (16) is sufficient for very good accuracy of the model. Accuracy was checked by comparison of the simulated transfer curve of the displacement transducer to the measured transfer curve of the actual transducer. The agreement between the model and the measurement is very good. The model can be used to investigate the influence of various coil shapes and target materials on linearity and sensitivity of the Eddy-current displacement transducer.
引用
收藏
页码:384 / 391
页数:8
相关论文
共 10 条
[1]  
[Anonymous], 1977, ELECT DESIGNERS HDB
[2]   Calibration of circular loop antennas [J].
Aykan, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (02) :446-452
[3]   Determination of coating thickness of a copper-plated steel wire by measurement of the internal wire impedance [J].
Båvall, L .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (04) :1013-1019
[4]  
HAYT W.H, 1981, ENG ELECTROMAGNETICS
[5]   MEASURING THE THICKNESS OF A THIN-FILM CONDUCTOR USING SOLENOID COILS [J].
NAKANE, H ;
SOHARA, Y ;
OMORI, S .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (02) :429-432
[6]   SIMULTANEOUS MEASUREMENT OF THE RESISTIVITY AND PERMEABILITY OF A FILM SAMPLE WITH A DOUBLE COIL [J].
NONAKA, Y ;
NAKANE, H ;
MAEDA, T ;
HASUIKE, K .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (03) :679-682
[7]  
SKITEK GG, 1990, ELECTROMAGNETIC CONC
[8]   EXPERIMENTAL OPTIMIZATION OF THE PROBE FOR EDDY-CURRENT DISPLACEMENT TRANSDUCER [J].
VYROUBAL, D ;
ZELE, D .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (06) :995-1000
[9]   Simultaneous measurement of size and electromagnetic property of multilayered spherical sample [J].
Yamazaki, S ;
Nakane, H ;
Negishi, T ;
Tanaka, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (05) :1277-1282
[10]   Simultaneous measurement of electric and magnetic properties of a spherical sample [J].
Yamazaki, S ;
Negishi, T ;
Nakane, H ;
Tanaka, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1996, 45 (02) :473-477