Impact of Cryoballoon Freeze Duration on Long-Term Durability of Pulmonary Vein Isolation ICE Re-Map Study

被引:52
作者
Chen, Shaojie [1 ]
Schmidt, Boris [1 ]
Bordignon, Stefano [1 ]
Perrotta, Laura [1 ]
Bologna, Fabrizio [1 ]
Chun, K. R. Julian [1 ]
机构
[1] Frankfurt Acad Arrhythmias, Cardioangiol Ctr Bethanien, Med Klin 3, Agaples Markus Krankenhaus, Frankfurt, Germany
关键词
atrial fibrillation; catheter ablation; cryoballoon; pulmonary vein isolation; mapping; PAROXYSMAL ATRIAL-FIBRILLATION; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; ESOPHAGEAL LESIONS; TIME; ANATOMY;
D O I
10.1016/j.jacep.2019.03.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to evaluate the durability of pulmonary vein isolation (PVI) after 2 different freeze durations by using time-to-effect guided (ICE-T) second generation cryobattoon (CB2) ablation strategy in patients with atrial fibrillation (AF) undergoing repeat procedure. BACKGROUND CB2 represents a powerful technology for PVI. Recently, the ICE-T CB2 ablation strategy targeting a 240-s single freeze demonstrated fast and efficient PVI. To further optimize safety and efficacy, a shortened 3-min freeze duration has been suggested, but PVI durability remains unclear. METHODS Between May 1, 2013 and December 31, 2017, all CB2 ablations followed the ICE-T concept (target freeze: 240 s or 180 s). Patients undergoing a second procedure for arrhythmia recurrence were analyzed. Two groups were defined based on the index freeze duration (group A: 240 s vs. group B: 180 s). In all repeat procedures a 3-dimensional left-atrial map was obtained. Durability of PVI and localization of conduction gaps were compared. RESULTS Of 788 total patients, 106 (13%) underwent a second procedure (group A: 80 of 604 vs. group B: 26 of 184) after a mean of 377 days. There was no difference regarding PV occlusion and time-to-isolation in the index procedure between the 2 groups. No major complications occurred. During the second procedure, significantly more patients demonstrated durable isolation of all PV in group A (61% vs. 35%; p = 0.02) along with a significantly increased rate of PVI durability (88% vs. 69%, per vein; p = 0.001). Left-sided PV did significantly benefit from 240-s freeze (reconnection left superior PV: 6% vs. 27%; p = 0.004, left inferior PV: 14% vs. 39%; p = 0.006). CONCLUSIONS The ICE-T ablation strategy is associated with a high rate of durable PVI in patients with arrhythmia recurrence. Target freeze duration of 240 s versus 180 s is associated with significantly increased lesion durability, particularly at left-sided PV, without increasing complications. (C) 2019 Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:551 / 559
页数:9
相关论文
共 33 条
[1]   Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: Results from the Cryo-DOSING Study (Cryoballoon-ablation DOSING Based on the Assessment of Time-to-Effect and Pulmonary Vein Isolation Guidance) [J].
Aryana, Arash ;
Kenigsberg, David N. ;
Kowalski, Marcin ;
Koo, Charles H. ;
Lim, Hae W. ;
O'Neill, Padraig Gearoid ;
Bowers, Mark R. ;
Hokanson, Robert B. ;
Ellenbogen, Kenneth A. .
HEART RHYTHM, 2017, 14 (09) :1319-1325
[2]   Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis [J].
Aryana, Arash ;
Singh, Sheldon M. ;
Mugnai, Giacomo ;
de Asmundis, Carlo ;
Kowalski, Marcin ;
Pujara, Deep K. ;
Cohen, Andrew I. ;
Singh, Steve K. ;
Fuenzalida, Charles E. ;
Prager, Nelson ;
Bowers, Mark R. ;
O'Neill, Padraig Gearoid ;
Brugada, Pedro ;
d'Avila, Andre ;
Chierchia, Gian-Battista .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (03) :341-348
[3]   Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation [J].
Aryana, Arash ;
Mugnai, Giacomo ;
Singh, Sheldon M. ;
Pujara, Deep K. ;
de Asmundis, Carlo ;
Singh, Steve K. ;
Bowers, Mark R. ;
Brugada, Pedro ;
d'Avila, Andre ;
O'Neill, Padraig Gearoid ;
Chierchia, Gian-Battista .
HEART RHYTHM, 2016, 13 (02) :424-432
[4]  
Bordignon S, 2019, PACING CLIN ELECTROP
[5]   High rate of durable pulmonary vein isolation after second-generation cryoballoon ablation: analysis of repeat procedures [J].
Bordignon, Stefano ;
Fuernkranz, Alexander ;
Perrotta, Laura ;
Dugo, Daniela ;
Konstantinou, Athanasios ;
Nowak, Bernd ;
Schulte-Hahn, Britta ;
Schmidt, Boris ;
Chun, Kyoung Ryul Julian .
EUROPACE, 2015, 17 (05) :725-731
[6]   Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: A comparison between the first- and second-generation balloon [J].
Casado-Arroyo, Ruben ;
Chierchia, Gian-Battista ;
Conte, Giulio ;
Levinstein, Moises ;
Sieira, Juan ;
Rodriguez-Manero, Moises ;
di Giovanni, Giacomo ;
Baltogiannis, Yannis ;
Wauters, Kristel ;
de Asmundis, Carlo ;
Sarkozy, Andrea ;
Brugada, Pedro .
HEART RHYTHM, 2013, 10 (09) :1318-1324
[7]   Compound motor action potential guided 240seconds plus bonus freeze for safe and durable left atrial appendage isolation in patients with recurrent persistent atrial fibrillation: How to isolate the appendage with cryoballoon (the CMAP guided ICE-B protocol) [J].
Chen, Shaojie ;
Schmidt, Boris ;
Bordignon, Stefano ;
Perrotta, Laura ;
Bologna, Fabrizio ;
Nagase, Takahiko ;
Chun, K. R. Julian .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (02) :272-283
[8]   Atrial fibrillation ablation using cryoballoon technology: Recent advances and practical techniques [J].
Chen, Shaojie ;
Schmidt, Boris ;
Bordignon, Stefano ;
Bologna, Fabrizio ;
Perrotta, Laura ;
Nagase, Takahiko ;
Chun, K. R. Julian .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (06) :932-943
[9]   Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up [J].
Chierchia, Gian-Battista ;
Di Giovanni, Giacomo ;
Ciconte, Giuseppe ;
de Asmundis, Carlo ;
Conte, Giulio ;
Sieira-Moret, Juan ;
Rodriguez-Manero, Moises ;
Casado, Ruben ;
Baltogiannis, Giannis ;
Namdar, Mehdi ;
Saitoh, Yukio ;
Paparella, Gaetano ;
Mugnai, Giacomo ;
Brugada, Pedro .
EUROPACE, 2014, 16 (05) :639-644
[10]   Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-Ttrial [J].
Chun, K. R. Julian ;
Stich, Marie ;
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Perrotta, Laura ;
Dugo, Daniela ;
Bologna, Fabrizio ;
Schmidt, Boris .
HEART RHYTHM, 2017, 14 (04) :495-500