Selective electrochemical sensor for copper (II) ion based on chelating ionophores

被引:72
作者
Singh, Ashok Kumar [1 ]
Mehtab, Sameena [1 ]
Jain, Ajay Kumar [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
chelating ionophore; poly(vinylchloride) membranes; copper-selective electrode; electrochemical sensors; selectivity;
D O I
10.1016/j.aca.2006.05.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plasticized membranes using 3-(2-pyridinyl)-2H-pyrido[1,2,-a]-1,3,5-triazine-2,4(3H)-dithione (L-1) and acetoacetanilide (L-2) have been prepared and explored as Cu2+-selective sensors. Effect of various plasticizers, viz. chloron4phthalene (CN), benzyl acetate (BA), o-nitrophenyloctyl ether (o-NPOE), and anion excluders, sodium tetraphenylborate (NaTPB) and oleic acid (OA) was studied in detail and improved performance was observed at several instances. Optimum performance was observed with dithione derivative (L-1) having a membrane composition of L, (5):PVC (120):o-NPOE (240):OA (10). The sensorworks satisfactorily in the concentration range 5.0 x 10(-8) to 1.0 x 10(-2) M] (detection limit 4.0 x 10-8 M) with a Nemstian slope of 29.5 mV decade-' of activity. Wide pH range (3.0-9.5), fast response time (12 s), non-aqueous tolerance (up to 20%) and adequate shelf life (4 months) indicate the vital utility of the proposed sensor. The potentiometric selectivity coefficient values as determined by match potential method (MPM) indicate good response for Cu 21 in presence of interfering ions. The proposed electrode comparatively shows good selectivity with respect to alkali, alkaline earth, transition and some rare earth metals ions. The electrode was used for the determination of copper in different milk powder, water samples and as indicator electrode in potentiometric titration of copper ion with EDTA. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 40 条
[1]   Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base [J].
Alizadeh, N ;
Ershad, S ;
Naeimi, H ;
Sharghi, H ;
Shamsipur, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06) :511-515
[2]   WILSON DISEASE AND MENKES DISEASE - NEW HANDLES ON HEAVY-METAL TRANSPORT [J].
BULL, PC ;
COX, DW .
TRENDS IN GENETICS, 1994, 10 (07) :246-252
[3]   A THEORY FOR EFFECTS OF NEUTRAL CARRIERS SUCH AS MACROTETRALIDE ACTIN ANTIBIOTICS ON ELECTRIC PROPERTIES OF BILAYER MEMBRANES [J].
CIANI, S ;
EISENMAN, G ;
SZABO, G .
JOURNAL OF MEMBRANE BIOLOGY, 1969, 1 (01) :1-&
[4]   Copper(II) complexes of new tetradentate NSNO pyridylthioazophenol ligands: synthesis, spectral and characterization and crystal structure [J].
Dhara, PK ;
Pramanik, S ;
Lu, TH ;
Drew, MGB ;
Chattopadhyay, P .
POLYHEDRON, 2004, 23 (16) :2457-2464
[5]  
Eyle E., 1971, ANAL CHEM, V43, P1090
[6]   Copper-selective PVC membrane electrodes based on salens as carriers [J].
Fakhari, AR ;
Raji, TA ;
Naeimi, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (02) :317-323
[7]  
Faust SD., 1987, ADSORPTION PROCESSES
[8]   Coated-wire copper(II)-selective electrode based on phenylglyoxal based on phenylglyoxal-α-monoxime ionophore [J].
Firooz, AR ;
Mazloum-Ardakani, M ;
Safari, J ;
Amini, MK .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (5-6) :718-722
[9]  
Ganjali MR, 2002, B KOREAN CHEM SOC, V23, P1394
[10]   Copper(II) ion-selective electrodes based on dithiosalicylic and thiosalicylic acids [J].
Gismera, MJ ;
Procopio, JR ;
Sevilla, MT ;
Hernández, L .
ELECTROANALYSIS, 2003, 15 (02) :126-132