Air reinjection and endothelial cell density in Descemet membrane endothelial keratoplasty: Five-year follow-up

被引:107
作者
Feng, Matthew T. [1 ]
Price, Marianne O. [2 ]
Miller, Jalee M. [2 ]
Price, Francis W., Jr. [1 ]
机构
[1] Price Vis Grp, Indianapolis, IN USA
[2] Cornea Res Fdn Amer, Indianapolis, IN 46260 USA
关键词
GRAFT-SURVIVAL; DMEK; DYSTROPHY; SURGERY; RISK; DSEK; EYES;
D O I
10.1016/j.jcrs.2014.04.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate 5-year endothelial cell loss after Descemet membrane endothelial keratoplasty (DMEK), compare it with reported rates for Descemet-stripping endothelial keratoplasty (DSEK) and penetrating keratoplasty (PKP), and investigate potential association between cell loss and air reinjection. SETTING: Price Vision Group, Indianapolis, Indiana, USA. DESIGN: Retrospective comparative case series. METHODS: Consecutive DMEK procedures performed between March 2008 and April 2013 were reviewed. The inclusion criterion was at least 6 months of follow-up. Endothelial cell density was recorded preoperatively and 1, 3, and 6 months and annually through 5 years postoperatively. Potential association between air reinjection and endothelial cell loss was evaluated by repeated measures analysis of variance. RESULTS: Of the 926 procedures performed, 673 eyes met the inclusion criterion. Indications for DMEK included Fuchs dystrophy (n = 595), pseudophakic corneal edema (n = 30), failed endothelial keratoplasty (n = 39), and failed PKP (n = 9). The median endothelial cell loss was 26% at 1 month, increasing to 39% at 5 years in cross-sectional and longitudinal analyses. Cell loss was similar in eyes with no (n = 471) or 1 (n = 155) air reinjection and significantly higher in eyes with 2 or more air reinjections (n = 47, P=.017). CONCLUSIONS: The median 5-year cell loss of 39% with DMEK compared favorably with prior reports of DSEK (53%) and PKP (70%) performed for similar indications. Similar to DSEK, most DMEK cell loss was associated with the surgical procedure itself; subsequent cell loss occurred at a slower rate than after PKP. Cell loss was not significantly increased in eyes with a single air reinjection. (C) 2014 ASCRS and ESCRS
引用
收藏
页码:1116 / 1121
页数:6
相关论文
共 27 条
  • [11] Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy: review of the first 50 consecutive cases
    Ham, L.
    Dapena, I.
    van Luijk, C.
    van der Wees, J.
    Melles, G. R. J.
    [J]. EYE, 2009, 23 (10) : 1990 - 1998
  • [12] Endothelial Cell Density after Descemet Membrane Endothelial Keratoplasty: 1-to 2-Year Follow-up
    Ham, Lisanne
    van Luijk, Chantal
    Dapena, Isabel
    Wong, Tse H.
    Birbal, Renuka
    van der Wees, Jacqueline
    Melles, Gerrit R. J.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (04) : 521 - 527
  • [13] Descemet Stripping Automated Endothelial Keratoplasty With a Donor Insertion Device: Clinical Results and Complications in 100 Eyes
    Khor, Wei-Boon
    Han, Sang-Beom
    Mehta, Jodhbir S.
    Tan, Donald T. H.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (04) : 773 - 779
  • [14] Early results of small-incision Descemet's stripping and automated endothelial keratoplasty
    Koenig, Steven B.
    Covert, Douglas J.
    [J]. OPHTHALMOLOGY, 2007, 114 (02) : 221 - 226
  • [15] Lass JH, 2008, OPHTHALMOLOGY, V115, P627, DOI [10.1016/j.ophtha.2008,01.004, 10.1016/j.ophtha.2008.01.004]
  • [16] Rapid sequential endothelial keratoplasty with and without combined cataract extraction
    McKee, Yuri
    Price, Marianne O.
    Gunderson, Lauren
    Price, Francis W., Jr.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (09) : 1372 - 1376
  • [17] Experience and 12-month results of Descemet-stripping endothelial keratoplasty (DSEK) with a small-incision technique
    Mearza, Ali A.
    Qureshi, Muhammad A.
    Rostron, Chad K.
    [J]. CORNEA, 2007, 26 (03) : 279 - 283
  • [18] Melles GRJ, 2006, CORNEA, V25, P987, DOI 10.1097/01.ico.0000248385.16896.34
  • [19] Descemet's membrane endothelial keratoplasty surgery: update on the evidence and hurdles to acceptance
    Price, Marianne O.
    Price, Francis W., Jr.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) : 329 - 335
  • [20] Comparison of Manual and Automated Endothelial Cell Density Analysis in Normal Eyes and DSEK Eyes
    Price, Marianne O.
    Fairchild, Kelly M.
    Price, Francis W., Jr.
    [J]. CORNEA, 2013, 32 (05) : 567 - 573