Enzyme-Based Glucose Sensor: From Invasive to Wearable Device

被引:606
作者
Lee, Hyunjae [1 ,2 ]
Hong, Yongseok Joseph [1 ,2 ]
Baik, Seungmin [1 ,2 ]
Hyeon, Taeghwan [1 ,2 ]
Kim, Dae-Hyeong [1 ,2 ]
机构
[1] Inst for Basic Sci Korea, Ctr Nanoparticle Res, Seoul 08826, South Korea
[2] Seoul Natl Univ, Inst Chem Proc, Sch Chem & Biol Engn, Seoul 08826, South Korea
关键词
diabetes; electrochemical analysis; glucose sensor; invasive glucose monitoring system; wearable device; SITE-DIRECTED MUTAGENESIS; WHOLE-BLOOD GLUCOSE; PRUSSIAN-BLUE; CARDIOVASCULAR-DISEASE; BIONIC PANCREAS; BIOFUEL CELLS; ELECTROCHEMICAL SENSORS; SUBSTRATE-SPECIFICITY; MOUTHGUARD BIOSENSOR; GLYCEMIC CONTROL;
D O I
10.1002/adhm.201701150
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood glucose concentration is a key indicator of patients' health, particularly for symptoms associated with diabetes mellitus. Because of the large number of diabetic patients, many approaches for glucose measurement have been studied to enable continuous and accurate glucose level monitoring. Among them, electrochemical analysis is prominent because it is simple and quantitative. This technology has been incorporated into commercialized and research-level devices from simple test strips to wearable devices and implantable systems. Although directly monitoring blood glucose assures accurate information, the invasive needle-pinching step to collect blood often results in patients (particularly young patients) being reluctant to adopt the process. An implantable glucose sensor may avoid the burden of repeated blood collections, but it is quite invasive and requires periodic replacement of the sensor owing to biofouling and its short lifetime. Therefore, noninvasive methods to estimate blood glucose levels from tears, saliva, interstitial fluid (ISF), and sweat are currently being studied. This review discusses the evolution of enzyme-based electrochemical glucose sensors, including materials, device structures, fabrication processes, and system engineering. Furthermore, invasive and noninvasive blood glucose monitoring methods using various biofluids or blood are described, highlighting the recent progress in the development of enzyme-based glucose sensors and their integrated systems.
引用
收藏
页数:14
相关论文
共 167 条
[1]   NAD-dependent dehydrogenase bioelectrocatalysis: the ability of a naphthoquinone redox polymer to regenerate NAD [J].
Abdellaoui, Sofiene ;
Milton, Ross D. ;
Quah, Timothy ;
Minteer, Shelley D. .
CHEMICAL COMMUNICATIONS, 2016, 52 (06) :1147-1150
[2]   A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration [J].
Abellan-Llobregat, A. ;
Jeerapan, Itthipon ;
Bandodkar, A. ;
Vidal, L. ;
Canals, A. ;
Wang, J. ;
Morallon, E. .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :885-891
[3]   Kidney Disease and Increased Mortality Risk in Type 2 Diabetes [J].
Afkarian, Maryam ;
Sachs, Michael C. ;
Kestenbaum, Bryan ;
Hirsch, Irl B. ;
Tuttle, Katherine R. ;
Hinnmelfarb, Jonathan ;
de Boer, Ian H. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2013, 24 (02) :302-308
[4]   Noninvasive Method for Glucose Level Estimation by Saliva [J].
Agrawal, R. P. ;
Sharma, N. ;
Rathore, M. S. ;
Gupta, V. B. ;
Jain, S. ;
Agarwal, V ;
Goyal, S. .
JOURNAL OF DIABETES & METABOLISM, 2013, 4 (05)
[5]  
Amer Diabet Assoc, 2013, DIABETES CARE, V36, pS67, DOI [10.2337/dc13-S067, 10.2337/dc14-S081, 10.2337/dc11-S062, 10.2337/dc10-S011, 10.2337/dc13-S011, 10.2337/dc11-S011, 10.2337/dc10-S062, 10.2337/dc12-s011, 10.2337/dc12-s064]
[6]  
[Anonymous], SCI REP
[7]  
[Anonymous], 2014, Critical Care
[8]  
[Anonymous], SCI REP
[9]  
[Anonymous], CRIT CARE
[10]  
[Anonymous], CURR MED CHEM