Three-dimensional evaluation of interradicular spaces and cortical bone thickness for the placement and initial stability of microimplants in adults

被引:91
|
作者
Park, Joorok
Cho, Heon Jae
机构
[1] Department of Orthodontics, Arthur A. Dugoni School of Dentistry, University of the Pacific, San Francisco, CA
[2] Department of Orthodontics, Arthur A. Dugoni School of Dentistry, University of the Pacific, San Francisco, CA
关键词
D O I
10.1016/j.ajodo.2009.04.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The objective of this retrospective study was to measure interradicular space, thickness of cortical bone, and alveolar process width at prospective microimplant placement sites in order to understand both safety and stability aspects of microimplant placement by using cone-beam 3-dimensional volumetric images. Methods: Initial 3-dimensional images of 60 adult patients (30 men, 30 women; mean age, 27.1 years) were reoriented by using a standardized protocol. Inter-radicular space, cortical bone thickness, and alveolar process width were obtained at the alveolar processes from canine to second molar at 3 different vertical levels from the cement enamel junction (CEJ). Palatal bone thickness was measured along the midpalate at 5 different distances from the distal edge of the incisal foramen. Peripheral palatal bone thickness was also measured at analogous locations, and cortical bone thickness of the retromolar pad was measured. Results: Maxillary interradicular distances ranged from 1.6 to 3.46 mm and tended to increase from the CEJ to the apex. They were the greatest between the second premolar and the first molar. Mandibular interradicular distances ranged from 1.99 to 4.25 mm and tended to be greater than maxillary interradicular spaces. Maxillary and mandibular buccal cortical bone thicknesses were 1.12 to 1.33 mm and 1.25 to 2.98 mm, respectively. In both jaws, buccal cortical bone thickness tended to increase from the CEJ to the apex. Alveolar process widths were 3.74 to 5.78 mm in the maxilla and 3.11 to 7.84 mm in the mandible. Along the midpalate, palatal bone 20 to 25 mm from the incisive foramen had 7.04 mm and 6.99 mm thickness, respectively. The retromolar pad areas showed 1.96 to 2.06 mm thicknesses of cortical bone. Conclusions: In the alveoloar process, 1 mm or more cortical bone thickness can be expected in the posterior dentition area. Safe locations for microimplant placements with adequate interradicular space are between the second premolar and the first molar in the maxillary buccal alveolar bone, between the molars in the maxillary palatal alveolar bone, and interradicular spaces from the first premolar to the second molar in the mandibular buccal alveolar bone. The midpalatal area and the retromolar pad area are also excellent locations for microimplant placement. Because of limited interradicular spaces, the recommended diameter of a microimplant is 1.2 to 1.6 mm for placement in the alveolar bone, and the recommended length is 6-7 mm.
引用
收藏
页码:314.e1 / 314.e12
页数:2
相关论文
共 50 条
  • [31] Three-Dimensional Reconstruction of Fleece Fabric Surface for Thickness Evaluation
    Jin, Shoufeng
    Chen, Yang
    Yin, Jiajie
    Li, Yi
    Gupta, Munish Kumar
    Fracz, Pawel
    Li, Zhixiong
    ELECTRONICS, 2020, 9 (09) : 1 - 12
  • [32] Evaluation of Three-Dimensional Volumetric Changes After Sinus Floor Augmentation with Mineralized Cortical Bone Allograft
    Berberi A.
    Bouserhal L.
    Nader N.
    Assaf R.B.
    Nassif N.B.
    Bouserhal J.
    Salameh Z.
    Journal of Maxillofacial and Oral Surgery, 2015, 14 (3) : 624 - 629
  • [33] Three-dimensional microcomputed tomography imaging of basic multicellular unit-related resorption spaces in human cortical bone
    Cooper, David M. L.
    Thomas, C. David L.
    Clement, John G.
    Hallgrimsson, Benedikt
    ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2006, 288A (07): : 806 - 816
  • [34] Three-dimensional evaluation for augmented bone using guided bone regeneration
    Tamura, T
    Yasumasa, F
    Goke, E
    Yamada, Y
    Sato, S
    Nishiyama, M
    Ito, K
    JOURNAL OF PERIODONTAL RESEARCH, 2005, 40 (03) : 269 - 276
  • [35] Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement
    Zhao, Hong
    Gu, Xiao-ming
    Liu, Hong-chen
    Wang, Zhao-wu
    Xun, Chun-lei
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (02) : 303 - 308
  • [36] Measurement of Cortical Bone Thickness in Adults by Cone-beam Computerized Tomography for Orthodontic Miniscrews Placement
    赵弘
    顾晓明
    刘洪臣
    王照五
    寻春雷
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2013, 33 (02) : 303 - 308
  • [37] Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement
    Hong Zhao
    Xiao-ming Gu
    Hong-chen Liu
    Zhao-wu Wang
    Chun-lei Xun
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2013, 33 : 303 - 308
  • [38] Ultrasonically determined thickness of long cortical bones: Three-dimensional simulations of in vitro experiments
    Moilanen, Petro
    Talmant, Maryline
    Nicholson, Patrick H. F.
    Cheng, Sulin
    Timonen, Jussi
    Laugier, Pascal
    Journal of the Acoustical Society of America, 2007, 122 (04): : 2439 - 2445
  • [39] Ultrasonically determined thickness of long cortical bones:: Three-dimensional simulations of in vitro experiments
    Moilanen, Petro
    Talmant, Maryline
    Nicholson, Patrick H. F.
    Cheng, Sulin
    Timonen, Jussi
    Laugier, Pascal
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (04): : 2439 - 2445
  • [40] THREE-DIMENSIONAL CORTICAL THICKNESS IN FEMORAL DIAPHYSIS FOR EALTHY ELDERLY AND OSTEOARTHRITIC KNEES IN WOMEN
    Hokari, S.
    Mochizuki, T.
    Tanifuji, O.
    OSTEOARTHRITIS AND CARTILAGE, 2018, 26 : S459 - S460