Gas-liquid membrane contactors for CO2 removal

被引:107
作者
Simons, Katja [1 ]
Nijmeijer, Kitty [1 ]
Wessling, Matthias [1 ]
机构
[1] Univ Twente, Inst Mech Proc & Control Twente IMPACT, Membrane Technol Grp, NL-7500 AE Enschede, Netherlands
关键词
Gas-liquid membrane contactor; CO2; capture; Monoethanolamine (MEA); Asymmetric hollow fiber membranes; Porous hollow fiber membranes; CARBON-DIOXIDE; AQUEOUS-SOLUTIONS; MASS-TRANSFER; ABSORPTION LIQUIDS; ELEVATED PRESSURES; FLUE-GAS; SEPARATION; SOLUBILITY; ALKANOLAMINES; MIXTURES;
D O I
10.1016/j.memsci.2009.05.035
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the present work we use a membrane contactor for the separation of CO2 from CH4 and we systematically investigate the influence of both the type of membrane and the different process parameters on the overall process performance (permeability and selectivity). This work is important because it reports real process performance data (permeances and selectivities) for the total process consisting of absorption and desorption under practical conditions using feed mixtures. Commercially available porous PP hollow fiber membranes and asymmetric PPO hollow fiber membranes have been applied and MEA was used as absorption liquid in the membrane contactor. The proposed approach allows us to identify the operating window and potential of the process. Although the performance of the PP membranes outperforms the performance of the PPO membranes in terms of productivity and selectivity, the PP fibers are extremely sensitive to only small variations in the feed pressure, resulting in severe performance loss. In addition to that, extremely high liquid losses are observed for the PIP fibers especially at elevated temperatures. Factors that are significantly reduced when asymmetric PPO membranes with a dense, ultrathin top layer are used, which thus improves the performance and significantly increases the operating window and potential of the membrane contactor process. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 50 条
  • [1] Biocatalytic gas-liquid membrane contactors for CO2 hydration with immobilized carbonic anhydrase
    Hou, Jingwei
    Zulkifli, Muhammad Yazid
    Mohammad, Munirah
    Zhang, Yatao
    Razmjou, Amir
    Chen, Vicki
    JOURNAL OF MEMBRANE SCIENCE, 2016, 520 : 303 - 313
  • [2] Evaluation of the removal of CO2 using membrane contactors: Membrane wettability
    El-Naas, Muftah H.
    Al-Marzouqi, Mohamed
    Marzouk, Sayed A.
    Abdullatif, Nadia
    JOURNAL OF MEMBRANE SCIENCE, 2010, 350 (1-2) : 410 - 416
  • [3] Application of Methanol Absorbent for CO2 Removal in Gas-Liquid Hollow Fiber Membrane Contactors
    Atashi, H.
    Mahdavian, M.
    Zivdar, M.
    Mousavi, S. M.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (07) : 3003 - 3008
  • [4] Membrane-solvent selection for CO2 removal using membrane gas-liquid contactors
    Dindore, VY
    Brilman, DWF
    Geuzebroek, FH
    Versteeg, GF
    SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) : 133 - 145
  • [5] Performance evaluation of composite and microporous gas-liquid membrane contactors for CO2 removal from a gas mixture
    Amaral, R. A.
    Habert, A. C.
    Borges, C. P.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 102 : 202 - 209
  • [6] Investigation of CO2 removal by silica and CNT nanofluids in microporous hollow fiber membrane contactors
    Golkhar, A.
    Keshavarz, P.
    Mowla, D.
    JOURNAL OF MEMBRANE SCIENCE, 2013, 433 : 17 - 24
  • [7] Gas-liquid membrane contactors for acid gas removal: recent advances and future challenges
    Zhang, Yuan
    Wang, Rong
    CURRENT OPINION IN CHEMICAL ENGINEERING, 2013, 2 (02) : 255 - 262
  • [8] Deoxygenation of a CO2 Absorbent Based on Monoethanolamine in Gas-Liquid Membrane Contactors: Dynamic Process Modeling
    Kalmykov, D. O.
    Shirokih, S. A.
    Matveev, D. N.
    Petrova, I. V.
    Bazhenov, S. D.
    MEMBRANES AND MEMBRANE TECHNOLOGIES, 2024, 6 (04) : 248 - 258
  • [9] Biogas upgrading by CO2 removal with a highly selective natural amino acid salt in gas-liquid membrane contactor
    Yan, Shuiping
    He, Qingyao
    Zhao, Shuaifei
    Wang, Yuanyuan
    Ai, Ping
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2014, 85 : 125 - 135
  • [10] CO2 removal from anaesthesia circuits using gas-ionic liquid membrane contactors
    Martins, C. F.
    Neves, L. A.
    Chagas, R.
    Ferreira, L. M.
    Afonso, C. A. M.
    Crespo, J. G.
    Coelhoso, I. M.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 250