Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors

被引:27
作者
Khoury, Dirar S. [1 ]
Naware, Mihir [4 ]
Siou, Jeff [4 ]
Blomqvist, Andreas [4 ]
Mathuria, Nilesh S. [2 ]
Wang, Jianwen [1 ]
Shih, Hue-Teh [3 ]
Nagueh, Sherif F. [1 ]
Panescu, Dorin [4 ]
机构
[1] Methodist Hosp, Res Inst, Methodist DeBakey Heart & Vasc Ctr, Dept Cardiol, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Med, Cardiol Sect, Houston, TX 77030 USA
[3] Ctr Cardiac Arrhythmias, Houston, TX USA
[4] St Jude Med Inc, Cardiac Rhythm Management Div, Sylmar, CA USA
关键词
cardiac resynchronization therapy; hemodynamic monitoring; pulmonary edema; FEASIBILITY; MODEL;
D O I
10.1016/j.jacc.2008.12.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study was designed to investigate the properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy system. Background The monitoring of CHF has relied mainly on right-side heart sensors. Methods Fifteen normal dogs underwent implantation of cardiac resynchronization therapy systems using standard leads. An additional left atrial (LA) pressure lead sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathoracic and intracardiac vectors, were measured through ring (r), coil (c), and device Can electrodes. Results Congestive heart failure developed in all animals after 2 to 4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LV(r)-Can, -17%; LV(r)-RVr, -15%; LV(r)-RAr, -11%; RV(r)-Can, -12%; RV(c)-Can, -7%; and RA(r)-Can, -5%. The LV(r)-Can vector reflected both the fastest and largest change in impedance in comparison with vectors employing only right-side heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. Conclusions Impedance, acquired by different lead electrodes, has variable responses to CHF. Impedance vectors employing an LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients. (J Am Coll Cardiol 2009;53:1075- 81) c 2009 by the American College of Cardiology Foundation
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 9 条
[1]   Improved lung edema monitoring with coronary vein pacing leads: a simulation study [J].
Belalcazar, A ;
Patterson, RP .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (02) :475-487
[2]   Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure - The COMPASS-HF study [J].
Bourge, Robert C. ;
Abraham, William T. ;
Adamson, Philip B. ;
Aaron, Mark F. ;
Aranda, Juan M., Jr. ;
Magalski, Anthony ;
Zile, Michael R. ;
Smith, Andrew L. ;
Smart, Frank W. ;
O'Shaughnessy, Mark A. ;
Jessup, Mariell L. ;
Sparks, Brandon ;
Naftel, David L. ;
Stevenson, Lynne Warner .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1073-1079
[3]  
DIGGLE P, 2002, ANAL LONGITUDINAL DA, P131
[4]   Direct left atrial pressure monitoring in ambulatory heart failure patients - Initial experience with a new permanent implantable device [J].
Ritzema, Jay ;
Melton, Iain C. ;
Richards, A. Mark ;
Crozier, Ian G. ;
Frampton, Chris ;
Doughty, Robert N. ;
Whiting, James ;
Kar, Saibal ;
Eigler, Neal ;
Krum, Henry ;
Abraham, William T. ;
Troughton, Richard W. .
CIRCULATION, 2007, 116 (25) :2952-2959
[5]   Heart disease and stroke statistics - 2008 update - A report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee [J].
Rosamond, Wayne ;
Flegal, Katherine ;
Furie, Karen ;
Go, Alan ;
Greenlund, Kurt ;
Haase, Nancy ;
Hailpern, Susan M. ;
Ho, Michael ;
Howard, Virginia ;
Kissela, Bret ;
Kittner, Steven ;
Lloyd-Jones, Donald ;
McDermott, Mary ;
Meigs, James ;
Moy, Claudia ;
Nichol, Graham ;
O'Donnell, Christopher ;
Roger, Veronique ;
Sorlie, Paul ;
Steinberger, Julia ;
Thom, Thomas ;
Wilson, Matt ;
Hong, Yuling .
CIRCULATION, 2008, 117 (04) :E25-E146
[6]   Intracardiac impedance monitors hemodynamic deterioration in a chronic heart failure pig model [J].
Stahl, Carsten ;
Beierlein, Wolfram ;
Walker, Tobias ;
Straub, Andreas ;
Nagy, Zolt ;
Knubben, Karolin ;
Greiner, Tim O. ;
Lippert, Michael ;
Czygan, Gerald ;
Paule, Stefan ;
Schweika, Oliver ;
Kuehlkamp, Volker .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (09) :985-990
[7]   Feasibility of using an implantable system to measure thoracic congestion in an ambulatory chronic heart failure canine model [J].
Wang, L ;
Lahtinen, S ;
Lentz, L ;
Rakow, N ;
Kaszas, C ;
Ruetz, L ;
Stylos, L ;
Olson, WH .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (05) :404-411
[8]  
Young SS., 1993, RESAMPLING BASED MUL, P184
[9]   Intrathoracic impedance monitoring in patients with heart failure - Correlation with fluid status and feasibility of early warning preceding hospitalization [J].
Yu, CM ;
Wang, L ;
Chau, E ;
Chan, RHW ;
Kong, SL ;
Tang, MO ;
Christensen, J ;
Stadler, RW ;
Lau, CP .
CIRCULATION, 2005, 112 (06) :841-848