Pulsed S-parameter measurements: on resolution, and uncertainty

被引:0
作者
Martens, J. [1 ]
机构
[1] Anritsu Co, Morgan Hill, CA 95037 USA
来源
2013 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, COMMUNICATIONS, ANTENNAS AND ELECTRONICS SYSTEMS (IEEE COMCAS 2013) | 2013年
关键词
mm-wave; network analyzer; pulse profile; power; nonlinearity; uncertainty; RF;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the timing and uncertainty requirements continue to increase for pulsed S-parameter measurements, it may be worth revisiting the effects of time resolution, time duration (either in terms of number of pulses or period) and measurement architecture on uncertainties. The advent of highly linear, faster digitizers has enabled improved resolution for constant uncertainty, sometimes at the expense of duration or range of pulse periods allowed but data processing changes can get around a number of those issues. A newer structure will be presented allowing resolutions down to 2.5ns simultaneously with pulsed periods in the 100 ms range and transmission uncertainties on the scale of 0.1 dB/1 deg to 40 GHz and higher depending on the setup. The effects of a number of the structural options on uncertainty are discussed along with complications introduced by additional pulse parameter dependencies.
引用
收藏
页数:5
相关论文
共 50 条
[21]   Uncertainty Analysis for Noise-Parameter Measurements at NIST [J].
Randa, James .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) :1146-1151
[22]   Connector Conversion Technique for General-Purpose Connectors in S-parameter Calibration [J].
Nakamura, Shintaro ;
Kishikawa, Ryoko ;
Sato, Keiko ;
Horibe, Masahiro .
2016 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (URSI AP-RASC), 2016, :483-484
[23]   Uncertainty Analysis of Traceable Measurements of Pulsed Magnetic Fields Used in Magnetotherapy [J].
Ulvr, Michal .
IEEE TRANSACTIONS ON MAGNETICS, 2025, 61 (06)
[24]   On high resolution, pulse-profiled mm-wave intermodulation measurements [J].
Martens, J. .
2013 EUROPEAN MICROWAVE CONFERENCE (EUMC), 2013, :1363-1366
[25]   On high resolution, pulse-profiled mm-wave intermodulation measurements [J].
Martens, J. .
2013 8TH EUROPEAN MICROWAVE INTEGRATED CIRCUITS CONFERENCE (EUMIC), 2013, :392-395
[26]   Characterization and Modeling of a GaAsSb/InGaAs Backward Diode on the Basis of S-Parameter Measurement Up to 67 GHz [J].
Yamashita, Shinpei ;
Suhara, Michihiko ;
Kawaguchi, Kenichi ;
Takahashi, Tsuyoshi ;
Sato, Masaru ;
Okamoto, Naoya ;
Asakawa, Kiyoto .
IEICE TRANSACTIONS ON ELECTRONICS, 2019, E102C (06) :462-465
[27]   Using neural networks for high resolution distance measurements in pulsed laser radar [J].
Joodaki, M ;
Kompa, G ;
Ahmadi, V ;
Farshi, MKM .
IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, :1242-1246
[28]   Uncertainty of the measurements in antenatal screening for Down's syndrome [J].
Loucky, Jaroslav .
AKTUALNI GYNEKOLOGIE A PORODNICTVI, 2010, 2 :5-9
[29]   A Novel Method for Estimating Residual Model Parameters to Evaluate Uncertainty in Scattering Parameter Measurements [J].
Cho, Chihyun ;
Kang, Tae-Weon ;
Kwon, Jae-Yong ;
Koo, Hyunji .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
[30]   Uncertainty of high resolution inductively coupled plasma mass spectrometry based aerosol measurements [J].
Yenisoy-Karakas, Serpil ;
Gaga, Eftade O. ;
Cankur, Oktay ;
Karakas, Duran .
TALANTA, 2009, 79 (05) :1298-1305