Detection and manipulation of biomolecules by magnetic carriers

被引:72
作者
Brzeska, M
Panhorst, M
Kamp, PB
Schotter, J
Reiss, G
Pühler, A
Becker, A
Brückl, H
机构
[1] Univ Bielefeld, Dept Phys, D-33615 Bielefeld, Germany
[2] Univ Bielefeld, Dept Genet, D-33615 Bielefeld, Germany
关键词
molecular recognition; biochip; marker; sensor; magnetoresistive; bonding force;
D O I
10.1016/j.jbiotec.2004.04.018
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The detection and manipulation of single molecules on a common platform would be of great interest for basic research of biological or chemical systems. A promising approach is the application of magnetic carriers. The principles are demonstrated in this contribution. It is shown that paramagnetic beads can be detected by highly sensitive magnetoresistive sensors yielding a purely electronic signal. Different configurations are discussed. The capability of the sensors to detect even single markers is demonstrated by a model experiment. In addition, the paramagnetic beads can be used as carriers for biomolecules. They can be manipulated on-chip via currents running through specially designed line patterns. Thus, magnetic markers in combination with magnetoresistive sensors are a promising choice for future integrated lab-on-a-chip systems. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 15 条
  • [1] GIANT MAGNETORESISTANCE OF (001)FE/(001) CR MAGNETIC SUPERLATTICES
    BAIBICH, MN
    BROTO, JM
    FERT, A
    VANDAU, FN
    PETROFF, F
    EITENNE, P
    CREUZET, G
    FRIEDERICH, A
    CHAZELAS, J
    [J]. PHYSICAL REVIEW LETTERS, 1988, 61 (21) : 2472 - 2475
  • [2] A biosensor based on magnetoresistance technology
    Baselt, DR
    Lee, GU
    Natesan, M
    Metzger, SW
    Sheehan, PE
    Colton, RJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) : 731 - 739
  • [3] Brückl H, 2003, ADV SOLID STATE PHYS, V43, P397
  • [4] Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications
    Graham, DL
    Ferreira, H
    Bernardo, J
    Freitas, PP
    Cabral, JMS
    [J]. JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) : 7786 - 7788
  • [5] LAYERED MAGNETIC-STRUCTURES - EVIDENCE FOR ANTIFERROMAGNETIC COUPLING OF FE LAYERS ACROSS CR INTERLAYERS
    GRUNBERG, P
    SCHREIBER, R
    PANG, Y
    BRODSKY, MB
    SOWERS, H
    [J]. PHYSICAL REVIEW LETTERS, 1986, 57 (19) : 2442 - 2445
  • [6] GRUTTER P, 1992, SCANNING TUNNELING M, V2, P152
  • [7] On-chip manipulation and magnetization assessment of magnetic bead ensembles by integrated spin-valve sensors
    Lagae, L
    Wirix-Speetjens, R
    Das, J
    Graham, D
    Ferreira, H
    Freitas, PPF
    Borghs, G
    De Boeck, J
    [J]. JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) : 7445 - 7447
  • [8] Microelectromagnets for the control of magnetic nanoparticles
    Lee, CS
    Lee, H
    Westervelt, RM
    [J]. APPLIED PHYSICS LETTERS, 2001, 79 (20) : 3308 - 3310
  • [9] LARGE MAGNETORESISTANCE AT ROOM-TEMPERATURE IN FERROMAGNETIC THIN-FILM TUNNEL-JUNCTIONS
    MOODERA, JS
    KINDER, LR
    WONG, TM
    MESERVEY, R
    [J]. PHYSICAL REVIEW LETTERS, 1995, 74 (16) : 3273 - 3276
  • [10] *OOMMF, 2003, OOMMF SOFTW