Video-Assisted Navigation for Adjustment of Image-Guidance Accuracy to Slight Brain Shift

被引:21
作者
Kantelhardt, Sven R. [1 ]
Gutenberg, Angelika [1 ]
Neulen, Axel [1 ]
Keric, Naureen [1 ]
Renovanz, Mirjam [1 ]
Giese, Alf [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Neurosurg, D-55129 Mainz, Germany
关键词
Augmented reality; Brain-shift adjustment; Image guidance; Registration accuracy; Microscope image-injection; NEURONAVIGATION SYSTEM; SURGERY; EXPERIENCES; REALITY;
D O I
10.1227/NEU.0000000000000921
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Information supplied by an image-guidance system can be superimposed on the operating microscope oculars or on a screen, generating augmented reality. Recently, the outline of a patient's head and skull, injected in the oculars of a standard operating microscope, has been used to check the registration accuracy of image guidance. OBJECTIVE: To propose the use of the brain surface relief and superficial vessels for real-time intraoperative visualization and image-guidance accuracy and for intra, operative adjustment for brain shift. METHODS: A commercially available image-guidance system and a standard operating microscope were used. Segmentation of the brain surface and cortical blood vessel relief was performed manually on preoperative computed tomography and magnetic resonance images. The overlay of segmented digital and real operating-microscope images was used to monitor image-guidance accuracy. Adjustment for brain shift was performed by manually matching digital images on real structures. RESULTS: Experimental manipulation on a phantom proved that the brain surface relief could be used to restore accuracy if the primary registration shifted. Afterward, the technique was used to assist during surgery of 5 consecutive patients With: 7 deep-seated brain tumors. The brain surface relief could be successfully used to monitor registration accuracy after craniotomy and during the whole procedure. If a certain degree of brain shift occurred after craniotomy, the accuracy could be restored in all cases, and corticotomies were correctly centered in all cases. CONCLUSION: The proposed method was easy to perform and augmented image-guidance accuracy when operating on small deep-seated lesions.
引用
收藏
页码:504 / 511
页数:8
相关论文
共 14 条
  • [1] Augmented Reality in the Surgery of Cerebral Aneurysms: A Technical Report
    Stadie, Axel Thomas
    [J]. OPERATIVE NEUROSURGERY, 2014, 10 (02) : 260 - 260
  • [2] Head-mounted display system for microneurosurgery
    Chen, JCT
    Moffitt, K
    Levy, ML
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 68 (1-4) : 25 - 32
  • [3] Edwards P J, 1995, J Image Guid Surg, V1, P172, DOI 10.1002/(SICI)1522-712X(1995)1:3<172::AID-IGS7>3.0.CO
  • [4] 2-7
  • [5] GLEASON PL, 1994, STEREOT FUNCT NEUROS, V63, P139, DOI 10.1159/000100305
  • [6] BrainLab VectorVision neuronavigation system: Technology and clinical experiences in 131 cases
    Gumprecht, HK
    Widenka, DC
    Lumenta, CB
    [J]. NEUROSURGERY, 1999, 44 (01) : 97 - 104
  • [7] Evaluation of a Completely Robotized Neurosurgical Operating Microscope
    Kantelhardt, Sven R.
    Finke, Markus
    Schweikard, Achim
    Giese, Alf
    [J]. NEUROSURGERY, 2013, 72 : A19 - A26
  • [8] Use of High-Field Intraoperative Magnetic Resonance Imaging to Enhance the Extent of Resection of Enhancing and Nonenhancing Gliomas
    Mohammadi, Alireza Mohammad
    Sullivan, T. Barrett
    Barnett, Gene H.
    Recinos, Violette
    Angelov, Lilyana
    Kamian, Kambiz
    Vogelbaum, Michael A.
    [J]. NEUROSURGERY, 2014, 74 (04) : 339 - 348
  • [9] Accuracy and clinical applicability of a passive marker based frameless neuronavigation system
    Muacevic, A
    Uhl, E
    Steiger, HJ
    Reulen, HJ
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2000, 7 (05) : 414 - 418
  • [10] Comparative study of application accuracy of two frameless neuronavigation systems: experimental error assessment quantifying registration methods and clinically influencing factors
    Paraskevopoulos, Dimitrios
    Unterberg, Andreas
    Metzner, Roland
    Dreyhaupt, Jens
    Eggers, Georg
    Wirtz, Christian Rainer
    [J]. NEUROSURGICAL REVIEW, 2011, 34 (02) : 217 - 228