Quantification of EGFP expression on molt-4 T cells using calibration standards

被引:14
作者
Gerena-López, Y
Nolan, J
Wang, L
Gaigalas, A
Schwartz, A
Fernández-Repollet, E
机构
[1] Univ Puerto Rico, Sch Med, Dept Pharmacol, San Juan, PR 00936 USA
[2] Los Alamos Natl Lab, Div Biosci, Los Alamos, NM USA
[3] NIST, Gaithersburg, MD 20899 USA
关键词
EGFP; molt-4 T cells; fluorescence quantification; MESF;
D O I
10.1002/cyto.a.20019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Enhanced green fluorescent protein (EGFP) is used extensively to assess gene expression on cells; however, quantification of this expression by flow cytometry has been limited by the unavailability of calibration standards. Thus, we characterized the response of an experimental set of EGFP calibration standards to environmental changes and then quantitate the expression of EGFP, in molecules of equivalent soluble fluorochrome (MESF) units, of a transfected Molt-4 T cell line by How cytometry. Methods: Characterization of the EGFP standards: EGFP standards were equilibrated in suspension solutions having a pH range of 5.0-9.0, temperatures of 37-80degreesC, and osmolalities of 100-600 mOsm/kg. Quantification of EGFP on cells: For transfections, Molt-4 T cells were incubated with two different concentrations (0.2 mug and 0.4 mug) of pEGFP-N2 vector and the EGFP expression was quantified after 48 h by flow cytometry using the EGFP standards and by the cytometry technique using a standard curve of known EGFP solutions. Results: The fluorescence intensity of the EGFP standards increased from pH 5.0 to 9.0 and remained relatively constant from 37degreesC to 65degreesC, and from 100 to 600 mOsm/ kg. After transfection, the expression of the populations with high and low EGFP expression averaged 8,098 +/- 584 MESF and 3,808 +/- 375 MESF respectively. No significant differences were observed after comparing the MESF values obtained by flow cytometry and the values obtained by Cytofluor technique (high: 8,791 +/- 492 MESF; low: 4,082 +/- 398 MESF). Conclusions: Our data demonstrate the feasibility of using calibration standards to quantify EGFP expression on cells. Our results emphasize the importance of monitoring the effects of environmental changes in the fluorescence intensity of both standards and samples when quantifying the expression of EGFP on living cells. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 22 条
[1]   Green fluorescent protein: Applications in cell biology [J].
Gerdes, HH ;
Kaether, C .
FEBS LETTERS, 1996, 389 (01) :44-47
[2]   WAVELENGTH MUTATIONS AND POSTTRANSLATIONAL AUTOXIDATION OF GREEN FLUORESCENT PROTEIN [J].
HEIM, R ;
PRASHER, DC ;
TSIEN, RY .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (26) :12501-12504
[3]  
KAIN SR, 1995, BIOTECHNIQUES, V19, P650
[4]   GREEN FLUORESCENT PROTEIN AS A NEW EXPRESSION MARKER IN MYCOBACTERIA [J].
KREMER, L ;
BAULARD, A ;
ESTAQUIER, J ;
POULAINGODEFROY, O ;
LOCHT, C .
MOLECULAR MICROBIOLOGY, 1995, 17 (05) :913-922
[5]   THERMOSENSITIVITY OF GREEN FLUORESCENT PROTEIN FLUORESCENCE UTILIZED TO REVEAL NOVEL NUCLEAR-LIKE COMPARTMENTS IN A MUTANT NUCLEOPORIN NSP1 [J].
LIM, CR ;
KIMATA, Y ;
OKA, M ;
NOMAGUCHI, K ;
KOHNO, K .
JOURNAL OF BIOCHEMISTRY, 1995, 118 (01) :13-17
[6]   ACIDIFICATION OF THE ENDOCYTIC AND EXOCYTIC PATHWAYS [J].
MELLMAN, I ;
FUCHS, R ;
HELENIUS, A .
ANNUAL REVIEW OF BIOCHEMISTRY, 1986, 55 :663-700
[7]   QUANTITATIVE IMAGING OF GREEN FLUORESCENT PROTEIN IN CULTURED-CELLS - COMPARISON OF MICROSCOPIC TECHNIQUES, USE IN FUSION PROTEINS AND DETECTION LIMITS [J].
NISWENDER, KD ;
BLACKMAN, SM ;
ROHDE, L ;
MAGNUSON, MA ;
PISTON, DW .
JOURNAL OF MICROSCOPY, 1995, 180 :109-116
[8]  
NOLAN JP, 2001, Patent No. 6326157
[9]   Use of the green fluorescent protein and its mutants in quantitative fluorescence microscopy [J].
Patterson, GH ;
Knobel, SM ;
Sharif, WD ;
Kain, SR ;
Piston, DW .
BIOPHYSICAL JOURNAL, 1997, 73 (05) :2782-2790
[10]   Chromophore formation in green fluorescent protein [J].
Reid, BG ;
Flynn, GC .
BIOCHEMISTRY, 1997, 36 (22) :6786-6791