Simultaneous determination of peroxydisulfate and conventional inorganic anions by ion chromatography with the column-switching technique

被引:23
作者
Huang, Zhongping [1 ]
Ni, Chengzhu [1 ]
Wang, Fengli [1 ]
Zhu, Zuoyi [1 ]
Subhani, Qamar [1 ]
Wang, Muhua [2 ]
Zhu, Yan [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Hangzhou 310028, Zhejiang, Peoples R China
[2] Lishui Univ, Dept Chem, Lishui, Peoples R China
关键词
Column switching; Conventional inorganic anions; Ion chromatography; Peroxydisulfate; SPECTROPHOTOMETRIC DETERMINATION; IODOMETRIC METHOD; AQUEOUS-SOLUTIONS; FLASH-PHOTOLYSIS; PERSULFATE; KINETICS; MICRODETERMINATION; EXCHANGE; DECOMPOSITION; SEPARATION;
D O I
10.1002/jssc.201300583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of ion chromatography with the column-switching technique for the simultaneous analysis of peroxydisulfate and conventional inorganic anions in a single run is described. With this method, conventional inorganic anions were separated by consecutive elution through both the guard column and separation column, but peroxydisulfate that only passed through the guard column had a good peak shape and short retention time. A series of standard solutions consisting of target anions of various concentrations from 0.01 to 75 mg/L were analyzed, with a correlation coefficient (r) >= 0.9990. The limits of detection were in the range of 0.49-9.84 mu g/L based on the S/N of 3 and a 25 mu L injection volume. RSDs for retention time, peak area, and peak height were all <1.77%. A spiking study was performed with satisfactory recoveries between 97.6 and 103.4% for all anions. The quantitative determination of peroxydisulfate and conventional inorganic anions in surface waters was accomplished within 18 min by this column-switching technique.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 28 条
[1]   TITRIMETRIC MICRO-DETERMINATION OF PEROXYDISULFATE BY AMPLIFICATION REACTIONS [J].
AMIN, D ;
HAREEZ, AK .
ANALYST, 1981, 106 (1268) :1221-1224
[3]  
BERLIN AA, 1986, KINET CATAL+, V27, P34
[4]   FLASH PHOTOLYSIS OF PERSULFATE IONS IN AQUEOUS SOLUTIONS . STUDY OF SULFATE AND OZONIDE RADICAL ANIONS [J].
DOGLIOTTI, L ;
HAYON, E .
JOURNAL OF PHYSICAL CHEMISTRY, 1967, 71 (08) :2511-+
[5]   AN IODOMETRIC METHOD FOR MACRO- AND MICRODETERMINATION OF PEROXYDISULFATE [J].
FRIGERIO, NA .
ANALYTICAL CHEMISTRY, 1963, 35 (03) :412-&
[6]   Determination of (fluoro)quinolones in environmental water using online preconcentration with column switching linked to large sample volumes and fluorescence detection [J].
Gil Garcia, Maria Dolores ;
Belmonte Gallegos, Angel ;
Santiago Valverde, Rosario ;
Martinez Galera, Maria .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (07) :823-831
[7]   FLASH PHOTOLYSIS IN VACUUM ULTRAVIOLET REGION OF SO42-CO32- AND OH- IONS IN AQUEOUS SOLUTIONS [J].
HAYON, E ;
MCGARVEY, JJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1967, 71 (05) :1472-&
[8]   KINETICS AND MECHANISM OF OXIDATIONS BY PEROXYDISULFATE [J].
HOUSE, DA .
CHEMICAL REVIEWS, 1962, 62 (03) :185-&
[9]   Kinetics of heat-assisted persulfate oxidation of methyl tert-butyl ether (MTBE) [J].
Huang, KC ;
Couttenye, RA ;
Hoag, GE .
CHEMOSPHERE, 2002, 49 (04) :413-420
[10]   A single pump cycling-column-switching technique coupled with homemade high exchange capacity columns for the determination of iodate in iodized edible salt by ion chromatography with UV detection [J].
Huang, Zhongping ;
Subhani, Qamar ;
Zhu, Zuoyi ;
Guo, Weiqiang ;
Zhu, Yan .
FOOD CHEMISTRY, 2013, 139 (1-4) :144-148