An innovative visual acuity chart for urgent and primary care settings: validation of the Runge near vision card

被引:10
作者
Cooke, Matthew D. [1 ]
Winter, Patricia A. [2 ]
McKenney, Kaitlin C. [2 ]
Packard, Krissa L. [2 ]
Williams, Vesper [2 ]
Dorsey, Eleanor A. [2 ]
Szabo, Aniko [3 ]
Visotcky, Alexis [3 ]
Warren, Clinton C. [2 ]
Wirostko, William J. [2 ]
Weinberg, David, V [2 ]
Kim, Judy E. [2 ]
Hang, Dennis P. [2 ]
机构
[1] Mayo Clin Hlth Syst, Eau Claire, WI USA
[2] Med Coll Wisconsin, Dept Ophthalmol & Visual Sci, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Inst Hlth & Soc, Milwaukee, WI 53226 USA
关键词
TREATMENT DIABETIC-RETINOPATHY; SNELLEN; EYE;
D O I
10.1038/s41433-019-0372-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective We evaluated the Runge card, a near-vision eye chart designed for ease of use, by testing agreement in visual acuity results between it and the Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity chart. As a clinical reference point, we compared the Runge card and an electronic Snellen chart with respect to agreement with ETDRS results. Methods Participants consisted of adult eye clinic patient volunteers who underwent a protocol refraction, followed by testing with a Runge card, ETDRS chart, and Snellen chart. Mean logMAR visual acuities were calculated for each method. Agreement levels among the tests were assessed for the group overall and for subjects with good (ETDRS logMAR < 0.6; better than 20/80 Snellen equivalent) and poor (logMAR >= 0.6) acuity. Results One hundred and thirty-eight participants completed testing. The mean (+/- standard deviation) logMAR visual acuities (Snellen equivalent) with Runge, ETDRS, and Snellen, respectively, were 0.66 +/- 0.50 (20/91, n = 138), 0.59 +/- 0.51 (20/78, n = 138), and 0.67 +/- 0.62 (20/94, n = 137). Runge testing agreed similarly with ETDRS and Snellen testing, with CCC 0.92 between Runge and ETDRS, and 0.87 between Runge and Snellen (p = 0.14). Runge agreed better with ETDRS than Snellen agreed with ETDRS in participants with poor acuity (CCC = 0.79 vs. 0.63, respectively, p = 0.001) but not in those with good acuity (CCC = 0.70 vs. 0.87, respectively, p = 0.005). Conclusion Visual acuity measurements with the Runge near card agreed with measurements from the ETDRS to approximately the same degree as did the Snellen chart, suggesting potential utility of the Runge near card, particularly given its user-friendly characteristics and ease of use.
引用
收藏
页码:1104 / 1110
页数:7
相关论文
共 15 条
[1]   MIDFACIAL FRACTURES AND THE EYE - THE DEVELOPMENT OF A SYSTEM FOR DETECTING PATIENTS AT RISK OF EYE INJURY [J].
ALQURAINY, IA ;
TITTERINGTON, DM ;
DUTTON, GN ;
STASSEN, LFA ;
MOOS, KF ;
ELATTAR, A .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1991, 29 (06) :363-367
[2]  
BAILEY IL, 1976, AM J OPTOM PHYS OPT, V53, P740
[3]   Reliability of the electronic early treatment diabetic retinopathy study testing protocol in children 7 to &lt;13 years old [J].
Cotter, SA ;
Chu, RH ;
Chandler, DL ;
Beck, RW ;
Holmes, JM ;
Rice, ML ;
Hertle, RW ;
Birch, EE ;
Moke, PS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (04) :655-661
[4]   Comparison of visual acuity in macular degeneration patients measured with Snellen and Early Treatment Diabetic Retinopathy Study Charts [J].
Falkenstein, Iryna A. ;
Cochran, Denine E. ;
Azen, Stanley P. ;
Dustin, Laurie ;
Tammewar, Ajay M. ;
Kozak, Igor ;
Freeman, William R. .
OPHTHALMOLOGY, 2008, 115 (02) :319-323
[5]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[6]   Warning on inaccurate Rosenbaum cards for testing near vision [J].
Horton, JC ;
Jones, MR .
SURVEY OF OPHTHALMOLOGY, 1997, 42 (02) :169-174
[7]  
Kaiser Peter K, 2009, Trans Am Ophthalmol Soc, V107, P311
[8]  
King T S, 2001, J Biopharm Stat, V11, P83, DOI 10.1081/BIP-100107651
[9]   Development of a clinically feasible logMAR alternative to the Snellen chart: performance of the ''compact reduced logMAR'' visual acuity chart in amblyopic children [J].
Laidlaw, DAH ;
Abbott, A ;
Rosser, DA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (10) :1232-1234
[10]   Random measurement error in visual acuity measurement in clinical settings [J].
Leinonen, J ;
Laakkonen, E ;
Laatikainen, L .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (03) :328-332