Motion analysis; Anatomical landmark calibration; Subject calibration; Protocol reliability; instrumented-pointer; ORIENTATION IN-SPACE; KNEE REPLACEMENT; GAIT ANALYSIS; KINEMATICS; MOVEMENT; STEREOPHOTOGRAMMETRY; RELIABILITY; MANAGEMENT; STABILITY; ARTIFACT;
D O I
10.1016/j.jbiomech.2017.01.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Instrumented-pointers are often used to calibrate anatomical landmarks in biomechanical analyses. However, little is known about the effect of altering the orientation of the pointer during calibration on the co-ordinates recorded. Incorrect positioning of a landmark influences the axes created, and thus the kinematic data recorded. This study aimed to investigate the reliability of the pointer method for anatomical calibration. Two points were drawn onto a fixed box to resemble knee joint epicondyles, then a custom-made pointer was used to define the positions of these landmarks in three-dimensions. Twenty different pointer-orientations were chosen, and the position of the pointer in each of these orientations was recorded 8 times. Euclidean distances between single points were calculated for both landmarks and compared statistically (alpha = 0.05). Average Euclidean distances between all reconstructed points were 3.2 +/- 1.4 mm (range: 0.3-7.1 mm) for one landmark and 33 +/- 1.5 mm (range: 0.3-7.9mm) for the other. The x-and y-co-ordinates recorded differed statistically when the pointer was moved about the X and Y axes (anterior/posterior and superior/inferior to landmark) (p < 0.05). No statistical differences were found between co-ordinates recorded when the pointer was moved around the Z axes (p > 0.05). ICC values for all co-ordinates were excellent, highlighting the reliability of the method (ICC > 0.90). These results support this method of anatomical calibration; however, we recommend that pointers be consistently held in a neutral oriented position (where the handle is not anterior, posterior, superior or inferior to the landmark) during calibration, to reduce the likelihood of calibration errors. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 22 条
[1]   Correcting for deformation in skin-based marker systems [J].
Alexander, EJ ;
Andriacchi, TP .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :355-361
[2]   Gait analysis methods in rehabilitation [J].
Baker, Richard .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2006, 3 (1)
[3]   Does medio-lateral motion occur in the normal knee? An in-vitro study in passive motion [J].
Belvedere, C. ;
Leardini, A. ;
Giannini, S. ;
Ensini, A. ;
Bianchi, L. ;
Catani, F. .
JOURNAL OF BIOMECHANICS, 2011, 44 (05) :877-884
[4]   Data management in gait analysis for clinical applications [J].
Benedetti, MG ;
Catani, F ;
Leardini, A ;
Pignotti, E ;
Giannini, S .
CLINICAL BIOMECHANICS, 1998, 13 (03) :204-215
[5]   Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo [J].
Benoit, Daniel L. ;
Ramsey, Dan K. ;
Lamontagne, Mario ;
Xu, Lanyi ;
Wretenberg, Per ;
Renstrom, Per .
GAIT & POSTURE, 2006, 24 (02) :152-164
[6]   Repeatability of gait data using a functional hip joint centre and a mean helical knee axis [J].
Besier, TF ;
Sturnieks, DL ;
Alderson, JA ;
Lloyd, DG .
JOURNAL OF BIOMECHANICS, 2003, 36 (08) :1159-1168
[7]   POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[8]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[9]   Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles [J].
Della Croce, U ;
Cappozzo, A ;
Kerrigan, DC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (02) :155-161
[10]   Human movement analysis using stereophotogrammetry - Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics [J].
Della Croce, U ;
Leardini, A ;
Chiari, L ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :226-237