Point shear wave elastography method for assessing liver stiffness

被引:123
作者
Ferraioli, Giovanna [1 ]
Tinelli, Carmine [2 ]
Lissandrin, Raffaella [1 ]
Zicchetti, Mabel [1 ]
Dal Bello, Barbara [3 ]
Filice, Gaetano [1 ]
Filice, Carlo [1 ]
机构
[1] Univ Pavia, Fdn IRCCS Policlin San Matteo, Sch Med, Dept Infect Dis, I-27100 Pavia, Italy
[2] Fdn IRCCS Policlin San Matteo, Clin Epidemiol & Biometr Unit, I-27100 Pavia, Italy
[3] Fdn IRCCS Policlin San Matteo, Dept Pathol, I-27100 Pavia, Italy
关键词
Chronic viral hepatitis; Liver biopsy; Liver fibrosis; Ultrasound; Elastography; Sensitivity and specificity; RADIATION FORCE IMPULSE; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; FIBROSIS; REPRODUCIBILITY; PERFORMANCE; ARFI; RELIABILITY; TECHNOLOGY;
D O I
10.3748/wjg.v20.i16.4787
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To estimate the validity of the point shear-wave elastography method by evaluating its reproducibility and accuracy for assessing liver stiffness. METHODS: This was a single-center, cross-sectional study. Consecutive patients with chronic viral hepatitis scheduled for liver biopsy (LB) (Group 1) and healthy volunteers (Group 2) were studied. In each subject 10 consecutive point shear-wave elastography (PSWE) measurements were performed using the iU22 ultrasound system (Philips Medical Systems, Bothell, WA, United States). Patients in Group 1 underwent PSWE, transient elastography (TE) using FibroScan (Echosens, Paris, France) and ultrasound-assisted LB. For the assessment of PSWE reproducibility two expert raters (rater 1 and rater 2) independently performed the examinations. The performance of PSWE was compared to that of TE using LB as a reference standard. Fibrosis was staged according to the METAVIR scoring system. Receiver operating characteristic curve analyses were performed to calculate the area under the receiver operating characteristic curve (AUC) for F = 2, F = 3 and F = 4. The intraobserver and interobserver reproducibility of PSWE were assessed by calculating Lin's concordance correlation coefficient. RESULTS: To assess the performance of PSWE, 134 consecutive patients in Group 1 were studied. The median values of PSWE and TE (in kilopascals) were 4.7 (IQR = 3.8-5.4) and 5.5 (IQR = 4.7-6.5), respectively, in patients at the F0-F1 stage and 3.5 (IQR = 3.2-4.0) and 4.4 (IQR = 3.5-4.9), respectively, in the healthy volunteers in Group 2 ( P < 10(-5)) In the univariate analysis, the PSWE and TE values showed a high correlation with the fibrosis stage; low correlations with the degree of necroinflammation, aspartate aminotransferase and gamma-glutamyl transferase (GGT); and a moderate negative correlation with the platelet count. A multiple regression analysis confirmed the correlations of both PSWE and TE with fibrosis stage and GGT but not with any other variables. The following AUC values were found: 0.80 (0.71-0.87) for PSWE and 0.82 (0.73-0.89) for TE (P = 0.42); 0.88 (0.80-0.94) for PSWE and 0.95 (0.88-0.98) for TE (P = 0.06); and 0.95 (0.89-0.99) for PSWE and 0.92 (0.85-0.97) for TE (P = 0.30) for F = 2, F = 3 and F = 4, respectively. To assess PSWE reproducibility, 116 subjects were studied, including 47 consecutive patients scheduled for LB (Group 1) and 69 consecutive healthy volunteers (Group 2). The intraobserver agreement ranged from 0.83 (95% CI: 0.79-0.88) to 0.96 (95% CI: 0.95-0.97) for rater 1 and from 0.84 (95% CI: 0.79-0.88) to 0.96 (95% CI: 0.95-0.97) for rater 2. The interobserver agreement yielded values from 0.83 (95% CI: 0.78-0.88) to 0.93 (95% CI: 0.91-0.95). CONCLUSION: PSWE is a reproducible method for assessing liver stiffness, and it compares with TE. Compared with patients with nonsignificant fibrosis, healthy volunteers showed significantly lower values. (C) 2014 Baishideng Publishing Group Co., Limited. All rights reserved.
引用
收藏
页码:4787 / 4796
页数:10
相关论文
共 38 条
[1]   Reliability of transient elastography for the diagnosis of advanced fibrosis in chronic hepatitis C [J].
Arena, U. ;
Vizzutti, F. ;
Abraldes, J. G. ;
Corti, G. ;
Stasi, C. ;
Moscarella, S. ;
Milani, S. ;
Lorefice, E. ;
Petrarca, A. ;
Romanelli, R. G. ;
Laffi, G. ;
Bosch, J. ;
Marra, F. ;
Pinzani, M. .
GUT, 2008, 57 (09) :1288-1293
[2]   An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[3]   Ultrasonographic evaluation of liver surface and transient elastography in clinically doubtful cirrhosis [J].
Berzigotti, Annalisa ;
Abraldes, Juan G. ;
Tandon, Puneeta ;
Erice, Eva ;
Gilabert, Rosa ;
Carlos Garcia-Pagan, Juan ;
Bosch, Jaime .
JOURNAL OF HEPATOLOGY, 2010, 52 (06) :846-853
[4]   INTRA- AND INTEROPERATOR REPRODUCIBILITY OF ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ELASTOGRAPHY-PRELIMINARY RESULTS [J].
Bota, Simona ;
Sporea, Ioan ;
Sirli, Roxana ;
Popescu, Alina ;
Danila, Mirela ;
Costachescu, Dan .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (07) :1103-1108
[5]   Determination of reliability criteria for liver stiffness evaluation by transient elastography [J].
Boursier, Jerome ;
Zarski, Jean-Pierre ;
de Ledinghen, Victor ;
Rousselet, Marie-Christine ;
Sturm, Nathalie ;
Lebail, Brigitte ;
Fouchard-Hubert, Isabelle ;
Gallois, Yves ;
Oberti, Frederic ;
Bertrais, Sandrine ;
Cales, Paul .
HEPATOLOGY, 2013, 57 (03) :1182-1191
[6]   Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis [J].
Boursier, Jerome ;
Isselin, Gael ;
Fouchard-Hubert, Isabelle ;
Oberti, Frederic ;
Dib, Nina ;
Lebigot, Jerome ;
Bertrais, Sandrine ;
Gallois, Yves ;
Cales, Paul ;
Aube, Christophe .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2010, 22 (09) :1074-1084
[7]   Reproducibility of Liver Stiffness Measurement by Ultrasonographic Elastometry [J].
Boursier, Jerome ;
Konate, Anselme ;
Gorea, Gabriella ;
Reaud, Stephanie ;
Quemener, Emmanuel ;
Oberti, Frederic ;
Hubert-Fouchard, Isabelle ;
Dib, Nina ;
Cales, Paul .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2008, 6 (11) :1263-1269
[8]   Current concepts: Liver biopsy. [J].
Bravo, AA ;
Sheth, SG ;
Chopra, S .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) :495-500
[9]   Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].
Castéra, L ;
Vergniol, J ;
Foucher, J ;
Le Bail, B ;
Chanteloup, E ;
Haaser, M ;
Darriet, M ;
Couzigou, P ;
De Lédinghen, V .
GASTROENTEROLOGY, 2005, 128 (02) :343-350
[10]   Non-invasive evaluation of liver fibrosis using transient elastography [J].
Castera, Laurent ;
Forns, Xavier ;
Alberti, Alfredo .
JOURNAL OF HEPATOLOGY, 2008, 48 (05) :835-847