A New Mini-External Fixator for Treating Hallux Valgus: A Preclinical, Biomechanical Study

被引:2
作者
Erdil, Mehmet [1 ]
Ceylan, Hasan Huseyin [2 ]
Polat, Gokhan [3 ]
Kara, Deniz [4 ]
Bozdag, Ergun [5 ]
Sunbuloglu, Emin [5 ]
机构
[1] Istanbul Medipol Univ, Fac Med, Dept Orthopaed & Traumatol, Istanbul, Turkey
[2] LNB State Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[3] Istanbul Univ, Fac Med, Dept Orthopaed & Traumatol, Istanbul, Turkey
[4] Bezmialem Vakif Univ, Fac Med, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Istanbul Tech Univ, Dept Mech Engn, TR-80626 Istanbul, Turkey
关键词
biomechanical stability; cannulated screw; external fixator; hallux valgus; proximal osteotomy; PROXIMAL CRESCENTIC OSTEOTOMY; PLATE; ETIOLOGY; SURGERY; SCREW;
D O I
10.1053/j.jfas.2015.04.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Proximal metatarsal osteotomy is the most effective technique for correcting hallux valgus deformities, especially in metatarsus primus varus. However, these surgeries are technically demanding and prone to complications, such as nonunion, implant failure, and unexpected extension of the osteotomy to the tarsometatarsal joint. In a preclinical study, we evaluated the biomechanical properties of the fixator and compared it with compression screws for treating hallux valgus with a proximal metatarsal osteotomy. Of 18 metatarsal composite bone models proximally osteotomized, 9 were fixed with a headless compression screw and 9 with the mini-external fixator. A dorsal angulation of 10 degrees and displacement of 10 mm were defined as the failure threshold values. Construct stiffness and the amount of interfragmentary angulation were calculated at various load cycles. All screw models failed before completing 1000 load cycles. In the fixator group, only 2 of 9 models (22.2%) failed before 1000 cycles, both between the 600th and 700th load cycles. The stability of fixation differed significantly between the groups (p < .001). The stability provided by the mini-external fixator was superior to that of compression screw fixation. Additional testing of the fixator is indicated. (C) 2016 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:35 / 38
页数:4
相关论文
共 22 条
[1]  
Amarnek D L, 1986, J Foot Surg, V25, P321
[2]  
Bozkurt Murat, 2004, J Foot Ankle Surg, V43, P138, DOI 10.1053/j.jfas.2004.03.010
[3]   EXTERNAL FIXATION IN HALLUX ABDUCTO VALGUS SURGERY [J].
DUKE, HF ;
WALTER, JH .
JOURNAL OF THE AMERICAN PODIATRY ASSOCIATION, 1982, 72 (09) :443-447
[4]   Prospective, randomized comparison of proximal crescentic and proximal chevron osteotomies for correction of hallux valgus deformity [J].
Easley, ME ;
Kiebzak, GM ;
Davis, WH ;
Anderson, RB .
FOOT & ANKLE INTERNATIONAL, 1996, 17 (06) :307-316
[5]   THE CHEVRON BUNIONECTOMY - A TRIGONOMETRIC ANALYSIS TO PREDICT CORRECTION [J].
GRAVES, SC ;
DUTKOWSKY, JP ;
RICHARDSON, EG .
FOOT & ANKLE, 1993, 14 (02) :90-96
[6]   SURGERY FOR ADOLESCENT HALLUX VALGUS [J].
HELAL, B ;
GUPTA, SK ;
GOJASENI, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1974, 45 (02) :271-295
[7]   Biomechanical comparison of screws and plates for hallux valgus opening-wedge and Ludloff osteotomies [J].
Hofstaetter, Stefan G. ;
Glisson, Richard R. ;
Alitz, Curtis J. ;
Trnka, Hans J. ;
Easley, Mark E. .
CLINICAL BIOMECHANICS, 2008, 23 (01) :101-108
[8]   Mechanical comparison of two types of fixation for proximal first metatarsal crescentic osteotomy [J].
Jones, C ;
Coughlin, M ;
Petersen, W ;
Herbot, M ;
Paletta, J .
FOOT & ANKLE INTERNATIONAL, 2005, 26 (05) :371-374
[9]   MATHEMATICAL-ANALYSIS OF 1ST METATARSAL OSTEOTOMIES [J].
KUMMER, FJ .
FOOT & ANKLE, 1989, 9 (06) :281-289
[10]   Immediate Weightbearing after Lapidus Arthrodesis with External Fixation [J].
Lamm, Bradley M. ;
Wynes, Jacob .
JOURNAL OF FOOT & ANKLE SURGERY, 2014, 53 (05) :577-583