The use of unipolar intracardiac impedance for discrimination of haemodynamically stable and unstable arrhythmias in man

被引:2
作者
Kaye, Gerry [1 ]
Arthur, Wayne
Edgar, Deborah
Lippert, Michael
Czygan, Gerald
机构
[1] E Yorkshire Hosp Trust, Dept Cardiol, Kingston Upon Hull HU7 3AZ, E Yorkshire, England
[2] E Yorkshire Hosp Trust, Dept Cardiol, Kingston Upon Hull HU7 3AZ, E Yorkshire, England
[3] Biotronik Uk Ltd, Bicester OX26 3WX, Oxon, England
[4] Biotronik GmbH & Co KG, Erlangen, Germany
来源
EUROPACE | 2006年 / 8卷 / 11期
关键词
unipolar intracardiac impedance; ventricular fibrillation; haemodynamic stability;
D O I
10.1093/europace/eul103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To determine the feasibility of discriminating haemodynamically stable from unstable arrhythmias using right ventricular (RV) unipolar intracardiac impedance (Z). Methods and results A quadrapolar temporary pacing electrode was positioned at the RV apex and unipolar impedance was measured between the tip electrode and a surface patch electrode. Changes in peak-to-peak Z amplitude were measured simultaneously with surface ECG and blood pressure during induced arrhythmias. Haemodynamic instability was defined as a systolic pressure of < 90 mmHg. There were 25 episodes of ventricular fibrillation (VF) induced in 15 patients, 18 episodes of ventricular tachycardia in 16 patients, and 33 episodes of supraventricular tachycardia (SVT) in 16 patients. Compared with the baseline rhythm, mean Z amplitude reduced from 51.3 +/- 7.7 to 11.2 +/- 7.4 Ohm (P < 0.001) during VF, from 52.2 +/- 6.3 to 21.7 +/- 10.1 Ohm (P < 0.01) during haemodynamically unstable VT, from 55.0 +/- 6.9 to 39.9 +/- 11 Ohm (ns) during stable VT, and from 56.4 +/- 8.4 to 36.9 +/- 9.3 Ohm during SVT (P < 0.001). Conclusion Right ventricular unipolar impedance is an adequate sensor for determining mechanical ventricular contraction and acts as a surrogate marker for a fall in arterial blood pressure during VF. However, for ventricular and supraventricular tachycardias, variations between patients did not allow adequate discrimination between stable and unstable arrhythmias.
引用
收藏
页码:988 / 993
页数:6
相关论文
共 10 条
[1]   DIFFERENTIATION OF ARRHYTHMIAS BY MEASUREMENT OF INTRACARDIAC PRESSURES IN MAN [J].
BEAUREGARD, LAM ;
VOLOSIN, KJ ;
WAXMAN, HL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :161-167
[2]   Measuring patient acceptance of implantable cardiac device therapy: Initial psychometric investigation of the Florida Patient Acceptance Survey [J].
Burns, JL ;
Serber, ER ;
Keim, S ;
Sears, SF .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (04) :384-390
[3]   HEMODYNAMIC-RESPONSES TO RAPID PACING - A MODEL FOR TACHYCARDIA DIFFERENTIATION [J].
COHEN, TJ ;
VELTRI, EP ;
LATTUCA, JJ ;
MOWER, MM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1522-1528
[4]   A PROSPECTIVE-STUDY OF CHANGES IN RIGHT VENTRICULAR DP/DT DURING VENTRICULAR-TACHYCARDIA [J].
KAPADIA, KA ;
WOOD, MA ;
LU, B ;
VALENTA, H ;
ELLENBOGEN, KA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (07) :1098-1104
[5]   CONTINUOUS RIGHT VENTRICULAR VOLUME ASSESSMENT BY CATHETER MEASUREMENT OF IMPEDANCE FOR ANTITACHYCARDIA SYSTEM CONTROL [J].
KHOURY, D ;
MCALISTER, H ;
WILKOFF, B ;
SIMMONS, T ;
RUDY, Y ;
MCCOWAN, R ;
MORANT, V ;
CASTLE, L ;
MALONEY, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (12) :1918-1926
[6]   Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor:: A multicenter, 12-month follow-up study of patients with chronic heart failure [J].
Magalski, A ;
Adamson, P ;
Gadler, F ;
Böehm, M ;
Steinhaus, D ;
Reynolds, D ;
Vlach, K ;
Linde, C ;
Cremers, B ;
Sparks, B ;
Bennett, T .
JOURNAL OF CARDIAC FAILURE, 2002, 8 (02) :63-70
[7]   Closed-loop stimulation using intracardiac impedance as a sensor principle:: Correlation of right ventricular dP/dtmax and intracardiac impedance during dobutamine stress test [J].
Osswald, S ;
Cron, T ;
Grädel, C ;
Hilti, P ;
Lippert, M ;
Ströbel, J ;
Schaldach, M ;
Buser, P ;
Pfisterer, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (10) :1502-1508
[8]   MEASUREMENT OF VENTRICULAR VOLUME BY INTRACARDIAC IMPEDANCE - THEORETICAL AND EMPIRICAL APPROACHES [J].
SALO, RW ;
WALLNER, TG ;
PEDERSON, BD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :189-195
[9]   A PROSPECTIVE-STUDY OF RIGHT VENTRICULAR PULSE PRESSURE AND DP/DT TO DISCRIMINANT-INDUCED VENTRICULAR-TACHYCARDIA FROM SUPRAVENTRICULAR AND SINUS TACHYCARDIA IN MAN [J].
WOOD, M ;
ELLENBOGEN, KA ;
LU, B ;
VALENTA, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (09) :1148-1157
[10]   RIGHT VENTRICULAR VOLUMETRY BY CATHETER MEASUREMENT OF CONDUCTANCE [J].
WOODARD, JC ;
BERTRAM, CD ;
GOW, BS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04) :862-870