Feasibility of combined ECG-Gated and Helical acquisition mode in a pre-TAVI computed tomography angiography protocol using a fixed low-volume contrast medium injection

被引:2
作者
Gallo, Giuseppe S. [1 ]
Gerasia, Roberta [1 ]
Caruso, Calogero [1 ]
Tafaro, Corrado [1 ]
Iannazzo, Erica [1 ]
Cannataci, Christine [2 ]
Gentile, Giovanni [1 ]
Mamone, Giuseppe [1 ]
Gandolfo, Caterina [3 ]
Miraglia, Roberto [1 ]
机构
[1] Mediterranean Inst Transplantat & Adv Specialized, Radiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
[2] Mater Dei Hosp, Med Imaging Dept, MSD-9032 Limsida, Malta
[3] Mediterranean Inst Transplantat & Adv Specialized, Intervent Cardiol Unit, Via Ernesto Tricomi 5, I-90127 Palermo, Italy
关键词
CT angiography; Contrast injection; Contrast-induced acute kidney injury; Transcatheter aortic valve implantation; AORTIC-VALVE IMPLANTATION; CT;
D O I
10.1016/j.ejrad.2020.109239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To investigate the feasibility, image quality, and clinical implications of a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI) using a fixed, low-volume, contrast medium injection. Methods: Between July and October 2019, 43 TAVI candidates underwent investigation with CTA using a 64-slice CT scanner. Images obtained were prospectively evaluated. 65 mL of low iodine dose contrast medium (CM), followed by 25 mL of saline, were administered using a fixed multiphasic injection protocol in all patients. Patients were divided into three groups based on BMI: Group 1 (n = 9) with BMI < 22 kg/m(2); Group 2 (n = 22) with BMI 22 29 kg/m2; Group 3 (n = 12) with BMI > 29 kg/m(2). Images were evaluated for image quality, vessel attenuation (HU), Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR) and estimated radiation dose. Image quality of the aortic root and iliac-femoral vessels was diagnostic in all patients. Results: Vascular attenuation was > 200 HU and CNR > 3 at all vessel levels. Conclusion: Data from our study suggest that it is possible to image the aortic annulus and aorto-iliac anatomy and obtain high image quality in all patients by using a combined ECG-gated and helical acquisition mode in a computed tomography angiography (CTA) protocol with a fixed low-volume contrast medium injection (65 mL). This allows for accurate CT measurements of the aortic annulus, recruitment of patients for TAVI and facilitates pre-procedural planning in these high surgical risk patients.
引用
收藏
页数:8
相关论文
共 15 条
[1]   Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume [J].
Almutairi, Abdulrahman ;
Sun, Zhonghua ;
Poovathumkadavi, Abduljaleel ;
Assar, Tarek .
PLOS ONE, 2015, 10 (09)
[2]   Ultra-Low Contrast Computed Tomographic Angiography (CTA) With 20-mL Total Dose for Transcatheter Aortic Valve Implantation (TAVI) Planning [J].
Azzalini, Lorenzo ;
Abbara, Suhny ;
Ghoshhajra, Brian B. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) :105-109
[3]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[4]   Scanner and kVp dependence of measured CT numbers in the ACR CT phantom [J].
Cropp, Robert J. ;
Seslija, Petar ;
Tso, David ;
Thakur, Yogesh .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06) :338-349
[5]  
European Society of Urogenital Radiology web-site, 2012, ESUR GUID CONTR MED
[6]   Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation [J].
Jilaihawi, Hasan ;
Kashif, Mohammad ;
Fontana, Gregory ;
Furugen, Azusa ;
Shiota, Takahiro ;
Friede, Gerald ;
Makhija, Rakhee ;
Doctor, Niraj ;
Leon, Martin B. ;
Makkar, Raj R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) :1275-1286
[7]   Low contrast media volume in pre-TAVI CT examinations [J].
Kok, Madeleine ;
Turek, Jakub ;
Mihl, Casper ;
Reinartz, Sebastian D. ;
Gohmann, Robin F. ;
Nijssen, Estelle C. ;
Kats, Suzanne ;
van Ommen, Vincent G. ;
Kietselaer, Bas L. J. H. ;
Wildberger, Joachim E. ;
Das, Marco .
EUROPEAN RADIOLOGY, 2016, 26 (08) :2426-2435
[8]  
Koo TK, 2017, J CHIROPR MED, V16, P346, DOI 10.1016/j.jcm.2017.10.001
[9]   A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J].
Koo, Terry K. ;
Li, Mae Y. .
JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) :155-163
[10]   A New Equation to Estimate Glomerular Filtration Rate [J].
Levey, Andrew S. ;
Stevens, Lesley A. ;
Schmid, Christopher H. ;
Zhang, Yaping ;
Castro, Alejandro F., III ;
Feldman, Harold I. ;
Kusek, John W. ;
Eggers, Paul ;
Van Lente, Frederick ;
Greene, Tom ;
Coresh, Josef .
ANNALS OF INTERNAL MEDICINE, 2009, 150 (09) :604-612