Determination of trace sulfur in biodiesel and diesel standard reference materials by isotope dilution sector field inductively coupled plasma mass spectrometry

被引:27
作者
Amais, Renata S. [1 ]
Long, Stephen E. [2 ]
Nobrega, Joaquim A. [1 ]
Christopher, Steven J. [2 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, BR-13560 Sao Carlos, SP, Brazil
[2] NIST, Div Chem Sci, Charleston, SC USA
基金
巴西圣保罗研究基金会;
关键词
Sulfur; Fuel; Microwave-assisted digestion; Diluted nitric acid; Isotope dilution; ID-SF-ICP-MS; MICROWAVE-ASSISTED DIGESTION; OPTICAL-EMISSION SPECTROMETRY; ICP-MS; FOSSIL-FUELS; GAS OILS; ACIDS;
D O I
10.1016/j.aca.2013.10.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for quantification of sulfur at low concentrations on the order of mg kg(-1) in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at S-32 and S-34 related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg(-1) S and 2.5 mg kg(-1) S (in the sample). The LOD was constrained by instrument background counts at S-32 but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 +/- 0.13 mg kg(-1). No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy. Published by Elsevier B.V.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 28 条
[1]  
Amais RS, 2012, J BRAZIL CHEM SOC, V23, P797, DOI 10.1590/S0103-50532012000500002
[2]  
[Anonymous], 5902009 EN
[3]   Effect of acid concentration on closed-vessel microwave-assisted digestion of plant materials [J].
Araújo, GCL ;
Gonzalez, MH ;
Ferreira, AG ;
Nogueira, ARA ;
Nóbrega, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :2121-2132
[4]   Accurate determination of S in organic matrices using isotope dilution ICP-MS/MS [J].
Balcaen, Lieve ;
Woods, Glenn ;
Resano, Martin ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (01) :33-39
[5]  
Becker J. S., 2008, INORGANIC MASS SPECT
[6]  
Burns D.A., 2011, US EPA CLEAN AIR MAR, P114
[7]   FUNDAMENTAL-STUDIES ON PNEUMATIC GENERATION AND AEROSOL TRANSPORT IN ATOMIC SPECTROMETRY - EFFECT OF MINERAL ACIDS ON EMISSION INTENSITY IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
TODOLI, JL ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :305-321
[8]   A critical evaluation of digestion procedures for coffee samples using diluted nitric acid in closed vessels for inductively coupled plasma optical emission spectrometry [J].
Castro, Jacira T. ;
Santos, Elisangela C. ;
Santos, Wagna P. C. ;
Costa, Leticia M. ;
Korn, Mauro ;
Nobrega, Joaquim A. ;
Korn, Maria Gracas A. .
TALANTA, 2009, 78 (4-5) :1378-1382
[9]   Use of factorial design for optimization of microwave-assisted digestion of lubricating oil [J].
Costa, LM ;
Ferreira, SLC ;
Nogueira, ARA ;
Nóbrega, JA .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (6A) :1269-1274
[10]   ISOTOPE-DILUTION MASS-SPECTROMETRY FOR ACCURATE ELEMENTAL ANALYSIS [J].
FASSETT, JD ;
PAULSEN, PJ .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :A643-&