Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements

被引:91
作者
Gietema, Hester A.
Wang, Ying
Xu, Dongming
van Klaveren, Rob J.
deKoning, Harry
Scholten, Ernst
Verschakelen, Johny
Kohl, Gerhard
Oudkerk, Matthijs
Prokop, Mathias
机构
[1] Univ Utrecht, Med Ctr, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Univ Groningen Hosp, Dept Radiol, NL-9700 RB Groningen, Netherlands
[3] Erasmus Med Ctr, Dept Pulmonol, Rotterdam, Netherlands
[4] Erasmus Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
[5] Siemens AG, Med Syst, D-8520 Erlangen, Germany
[6] Kennemer Gasthuis, Dept Radiol, Haarlem, Netherlands
[7] Univ Hosp St Gasthuisberg, Dept Radiol, Louvain, Belgium
关键词
D O I
10.1148/radiol.2411050860
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively determine interobserver variability of semiautomated volume measurements of pulmonary nodules and the potential reasons for variability. Materials and Methods: The Dutch-Belgian lung cancer screening trial (NELSON) is a lung cancer screening study that includes men between the ages of 50 and 75 years who are current or former heavy smokers. The NELSON project was approved by the Dutch Ministry of Health and the ethics committee of each participating hospital. Informed consent was obtained from all participants. For this study, the authors evaluated 1200 consecutive low-dose computed tomographic (CT) scans of the chest obtained during the NELSON project and identified subjects who had at least one 50-500-mm(3) nodule. One local and one central observer independently evaluated the scans and measured the volume of any detected nodule by using semiautomated software. Noncalcified solid nodules with volumes of 15-500 mm(3) were included in this study if they were fully surrounded by air (intraparenchymal) and were detected by both observers. The mean volume and the difference between both measurements were calculated for all nodules. Intermeasurement agreement was assessed with the Spearman correlation coefficient. Potential reasons for discrepancies were assessed. Results: There were 232 men (mean age, 60 years; age range, 52-73 years) with 430 eligible nodules (mean volume, 77.8 mm3; range, 15.3-499.5 mm3). Interobserver correlation was high (r = 0.99). No difference in volume was seen for 383 nodules (89.1%). Discrepant results were obtained for 47 nodules (10.9%); in 16 cases (3.7%), the discrepancy was larger than 10%. The most frequent cause of variability was incomplete segmentation due to an irregular shape or irregular margins. Conclusion: In a minority (approximately 11%) of small solid intraparenchymal nodules, semiautomated measurements are not completely reproducible and, thus, may cause errors in the assessment of nodule growth. For small or irregularly shaped nodules, an observer should check the segmentation shown by the program.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 21 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Screening for early lung cancer with low-dose spiral computed tomography: results of annual follow-up examinations in asymptomatic smokers
    Diederich, S
    Thomas, M
    Semik, M
    Lenzen, H
    Roos, N
    Weber, A
    Heindel, W
    Wormanns, D
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (04) : 691 - 702
  • [3] Lung cancer screening with low-dose CT
    Diederich, S
    Wormanns, D
    Heindel, W
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (01) : 2 - 7
  • [4] Automated lung nodule detection at low-dose CT: Preliminary experience
    Goo, JM
    Lee, JW
    Lee, HJ
    Kim, S
    Kim, JH
    Im, JG
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (04) : 211 - 216
  • [5] Growth rate of small lung cancers detected on mass CT screening
    Hasegawa, M
    Sone, S
    Takashima, S
    Li, F
    Yang, ZG
    Maruyama, Y
    Watanabe, T
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) : 1252 - 1259
  • [6] Henschke CI, 2001, CANCER, V92, P153, DOI 10.1002/1097-0142(20010701)92:1<153::AID-CNCR1303>3.0.CO
  • [7] 2-S
  • [8] Early Lung Cancer Action Project: overall design and findings from baseline screening
    Henschke, CI
    McCauley, DI
    Yankelevitz, DF
    Naidich, DP
    McGuinness, G
    Miettinen, OS
    Libby, DM
    Pasmantier, MW
    Koizumi, J
    Altorki, NK
    Smith, JP
    [J]. LANCET, 1999, 354 (9173) : 99 - 105
  • [9] Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT
    Kostis, WJ
    Yankelevitz, DF
    Reeves, AP
    Fluture, SC
    Henschke, CI
    [J]. RADIOLOGY, 2004, 231 (02) : 446 - 452
  • [10] Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the Fleischner Society
    MacMahon, H
    Austin, JHM
    Gamsu, G
    Herold, CJ
    Jett, JR
    Naidich, DP
    Patz, EF
    Swensen, SJ
    [J]. RADIOLOGY, 2005, 237 (02) : 395 - 400