Cold-Formed Steel Lipped Channel Section Columns Undergoing Local-Overall Buckling Interaction

被引:9
作者
Roy, Krishanu [1 ]
Tina Chui Huon Ting [2 ]
Lau, Hieng Ho [3 ]
Masood, Rehan [1 ,6 ]
Alyousef, Rayed [4 ]
Alabduljabbar, Hisham [4 ]
Alaskar, Abdulaziz [5 ]
Alrshoudi, Fahed [5 ]
Lim, James B. P. [1 ]
机构
[1] Univ Auckland, Dept Civil & Environm Engn, Bldg 906,Level 4,Room 413,Newmarket Campus, Auckland 1010, New Zealand
[2] Curtin Univ Sarawak, Sch Engn & Sci, Sarawak, Malaysia
[3] Swinburne Univ Technol, Fac Engn Comp & Sci, Sarawak, Malaysia
[4] Prince Sattam Bin Abdulaziz Univ, Coll Engn, Dept Civil Engn, Al Kharj 11942, Saudi Arabia
[5] King Saud Univ, Coll Engn, Dept Civil Engn, Riyadh 11362, Saudi Arabia
[6] Natl Univ Sci & Technol, Dept Construct Engn & Management, Islamabad, Pakistan
关键词
Buckling interaction; Cold-formed steel; Compression member; Finite element analysis; Local-overall buckling interaction; COMPRESSION TESTS; DESIGN; BEHAVIOR;
D O I
10.1007/s13296-020-00447-w
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental and finite element (FE) investigation into the local-overall buckling interaction behaviour of axially loaded cold-formed steel (CFS) channel section columns. Current design guidelines from the American Iron and Steel Institute (AISI) and the Australian and New Zealand Standards (AS/NZS) recommend the use of a non-dimensional strength curve for determining the axial capacity of such CFS channel section columns. This study has reviewed the accuracy of the current AISI (2016), AS/NZS (2018) and Eurocode (EN 1993-1-3) design guidelines for determining the axial capacity of CFS channel sections under local-overall buckling interaction failure. A total of 40 tests were conducted on CFS channel sections covering stub, short, intermediate, and slender columns with varying thicknesses. A nonlinear FE model was then developed and validated against the test results. The validated FE model was used to conduct a parametric study comprising 70 FE models to review the accuracy of the current design guidelines in accordance with AISI (2016), AS/NZS (2018) and Eurocode (EN 1993-1-3). It was found that the AISI (2016) and AS/NZS (2018) are conservative by 10 to 15% on average when determining the axial capacity of pin-ended CFS channel section columns undergoing local-overall buckling interaction. Eurocode (EN 1993-1-3) design rules were found to lead to considerably more conservative predictions of column axial load capacity for CFS channels.This paper has therefore proposed modifications to the current design rules of AISI (2016) and AS/NZS (2018). The accuracy of proposed design rules was verified using the FE analysis and test results of CFS channel section columns undergoing local-overall buckling interaction.
引用
收藏
页码:408 / 429
页数:22
相关论文
共 26 条
[1]  
ABAQUS, 2018, ABAQUS VERS 6 14 2
[2]  
AISI manual, 2016, S100 AISI NAS
[3]  
BS EN, 2001, TENS TEST MET MAT ME
[4]   Experimental investigation concerning lipped channel columns undergoing local-distortional-global buckling mode interaction [J].
dos Santos, Eliane S. ;
Batista, Eduardo M. ;
Camotim, Dinar .
THIN-WALLED STRUCTURES, 2012, 54 :19-34
[5]   Behavior of cold-formed steel plain angle columns [J].
Ellobody, E ;
Young, B .
JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (03) :457-466
[6]  
European Committee for Standardization (EC3), 2006, BS EN 1993-1-3
[7]   Improved design rules for fixed ended cold-formed steel columns subject to flexural-torsional buckling [J].
Gunalan, Shanmuganathan ;
Mahendran, Mahen .
THIN-WALLED STRUCTURES, 2013, 73 :1-17
[8]   STRENGTH DESIGN CURVES FOR THIN-WALLED SECTIONS UNDERGOING DISTORTIONAL BUCKLING [J].
HANCOCK, GJ ;
KOWN, YB ;
BERNARD, ES .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1994, 31 (2-3) :169-186
[9]  
Heva YB, 2013, STEEL COMPOS STRUCT, V14, P205
[10]   Flexural-Torsional Buckling Tests of Cold-Formed Lipped Channel Beams Under Restrained Boundary Conditions [J].
Kandasamy, R. ;
Thenmozhi, R. ;
Jeyagopal, L. S. .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (03) :765-776