Role of Contrast-Enhanced Ultrasound in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair

被引:4
作者
Benedetto, Filippo [1 ]
Spinelli, Domenico [1 ]
La Corte, Francesco [1 ]
Pipito, Narayana [1 ]
Passari, Gabriele [1 ]
De Caridi, Giovanni [1 ]
机构
[1] Univ Messina, Dipartimento Sci Biomed Odontoiatr & Immagini Mor, I-98122 Messina, Italy
关键词
contrast-enhanced ultrasound; duplex ultrasound; abdominal aortic aneurysm repair; endoleak; follow-up; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ENDOLEAKS; EVAR; COMPLICATIONS; INTERVENTION; SURVEILLANCE; GUIDELINES; SOCIETY; CEUS; CT;
D O I
10.3390/diagnostics12123173
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to assess whether contrast-enhanced ultrasound (CEUS) shows a false negative rate close to zero and therefore is suitable as the main non-invasive follow-up strategy for long-term monitoring after endovascular aortic repair (EVAR). Methods: We included all consecutive patients who underwent CEUS as follow-up after EVAR at our center between January 2017 and December 2021.The follow-up protocol consisted of Duplex ultrasound (DUS) with CEUS at 1, 3, 6 months postoperatively and every 6 months thereafter. Results: A total of 125 patients underwent 228 CEUS. The aneurysm sac showed shrinkage in 80 (64%) patients, stability in 32 (25.6%), and enlargement in 13 (10.4%). A total of 29 (23.2%) patients showed type 2 endoleak, 6 (4.8%) patients showed type 1 endoleak and 3 (2.4%) patients showed type 3 endoleak. Thirteen patients underwent one or more reinterventions. The sensitivity of CEUS vs. DUS was 100% vs. 75% (p > 0.0001). In classifying type 2 endoleak, CEUS compared to DUS showed a sensitivity of 93.2% vs. 59.4% and a specificity of 99.3% vs. 99.3%. CEUS showed a higher sensitivity compared to DUS in the detection of type 2 endoleak. CEUS permits the identification of a subset of patients requiring a stricter follow-up protocol.
引用
收藏
页数:9
相关论文
共 24 条
[1]   3D Contrast Enhanced Ultrasound for Detecting Endoleak Following Endovascular Aneurysm Repair (EVAR) [J].
Abbas, A. ;
Hansrani, V. ;
Sedgwick, N. ;
Ghosh, J. ;
McCollum, C. N. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (05) :487-492
[2]   Detection of Late Complications After Endovascular Abdominal Aortic Aneurysm Repair and Implications for Follow up Based on Retrospective Assessment of a Two Centre Cohort [J].
Baderkhan, Hassan ;
Wanhainen, Anders ;
Haller, Olov ;
Bjorck, Martin ;
Mani, Kevin .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 60 (02) :171-179
[3]   Contrast Enhanced Ultrasound can Replace Computed Tomography Angiography for Surveillance After Endovascular Aortic Aneurysm Repair [J].
Bredahl, K. K. ;
Taudorf, M. ;
Lonn, L. ;
Vogt, K. C. ;
Sillesen, H. ;
Eiberg, J. P. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 52 (06) :729-734
[4]   Prospective Comparative Analysis of Colour-Doppler Ultrasound, Contrast-enhanced Ultrasound, Computed Tomography and Magnetic Resonance in Detecting Endoleak after Endovascular Abdominal Aortic Aneurysm Repair [J].
Cantisani, V. ;
Ricci, P. ;
Grazhdani, H. ;
Napoli, A. ;
Fanelli, F. ;
Catalano, C. ;
Galati, G. ;
D'Andrea, V. ;
Biancari, F. ;
Passariello, R. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 41 (02) :186-192
[5]   EVAR: Benefits of CEUS for monitoring stent-graft status [J].
Cantisani, Vito ;
Grazhdani, Hektor ;
Clevert, Dirk-Andre ;
Iezzi, Roberto ;
Aiani, Luca ;
Martegani, Alberto ;
Fanelli, Fabrizio ;
Di Marzo, Luca ;
Wlderk, Andrea ;
Cirelli, Carlo ;
Catalano, Carlo ;
Di Leo, Nicola ;
Di Segni, Mattia ;
Malpassini, Flavio ;
D'Ambrosio, Ferdinando .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) :1658-1665
[6]   The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm [J].
Chaikof, Elliot L. ;
Dalman, Ronald L. ;
Eskandari, Mark K. ;
Jackson, Benjamin M. ;
Lee, W. Anthony ;
Mansour, M. Ashraf ;
Mastracci, Tara M. ;
Mell, Matthew ;
Murad, M. Hassan ;
Nguyen, Louis L. ;
Oderich, Gustavo S. ;
Patel, Madhukar S. ;
Schermerhorn, Marc L. ;
Starnes, Benjamin W. .
JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) :2-+
[7]   What is the role of contrast-enhanced ultrasound in the evaluation of the endoleak of aortic endoprostheses? A comparison between CEUS and CT on a widespread scale [J].
David E. ;
Cantisani V. ;
Grazhdani H. ;
Di Marzo L. ;
Venturini L. ;
Fanelli F. ;
Di Segni M. ;
Di Leo N. ;
Brunese L. ;
Calliada F. ;
Ciccariello M. ;
Bottari A. ;
Ascenti G. ;
D’Ambrosio F. .
Journal of Ultrasound, 2016, 19 (4) :281-287
[8]   A comparison between contrast-enhanced ultrasound imaging and multislice computed tomography in detecting and classifying endoleaks in the follow-up after endovascular aneurysm repair [J].
Guertler, Verena M. ;
Sommer, Wieland H. ;
Meimarakis, Georgios ;
Kopp, Reinhard ;
Weidenhagen, Rolf ;
Reiser, Maximilian F. ;
Clevert, Dirk-Andre .
JOURNAL OF VASCULAR SURGERY, 2013, 58 (02) :340-345
[9]   Is contrast-enhanced ultrasound (CEUS) superior to computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients? A systematic review and meta-analysis [J].
Harky, Amer ;
Zywicka, Ewa ;
Santoro, Giovanni ;
Jullian, Lucas ;
Joshi, Mihika ;
Dimitri, Sameh .
JOURNAL OF ULTRASOUND, 2019, 22 (01) :65-75
[10]   Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair A Prospective Multicenter Diagnostic-Accuracy Study (the ESSEA Trial) [J].
Jean-Baptiste, Elixene ;
Feugier, Patrick ;
Cruzel, Coralie ;
Sarlon-Bartoli, Gabrielle ;
Reix, Thierry ;
Steinmetz, Eric ;
Chaufour, Xavier ;
Chavent, Bertrand ;
du Mont, Lucie Salomon ;
Ejargue, Meghann ;
Maurel, Blandine ;
Spear, Rafaelle ;
Midy, Dominique ;
Thaveau, Fabien ;
Desgranges, Pascal ;
Rosset, Eugenio ;
Hassen-Khodja, Reda .
CIRCULATION-CARDIOVASCULAR IMAGING, 2020, 13 (06) :E009886