Development of a novel high-rate gaseous pixel detector for time-resolved X-ray diffraction applications

被引:0
作者
Sarvestani, A [1 ]
Besch, HJ [1 ]
Menk, RH [1 ]
Pavel, NA [1 ]
Walenta, AH [1 ]
机构
[1] Univ Gesamthsch Siegen, Fachbereich Phys, D-57068 Siegen, Germany
来源
DETECTORS FOR CRYSTALLOGRAPHY AND DIFFRACTION STUDIES AT SYNCHROTRON SOURCES | 1999年 / 3774卷
关键词
simulation of X-ray diffraction; detector optimization; gaseous single photon counter; 2D pixel detector; synchrotron experiments; small angle X-ray scattering; protein crystallography; time resolved studies;
D O I
10.1117/12.367116
中图分类号
O7 [晶体学];
学科分类号
0702 ; 070205 ; 0703 ; 080501 ;
摘要
Modern X-ray diffraction applications demand for imaging detectors with large pixel number, high intensity precision, high rate capability and dead time free operation. Detailed studies with a simulation program, which has been developed to investigate the performance of different detector types, show that a large area gaseous single photon counter is very well suited to meet the aforementioned requirements. The prototype detector, which has been built according to the specification profile from the simulations, belongs to a new generation of gaseous detectors using novel technologies for both gas amplification (using a MicroCAT) and position encoding (using 2D resistive charge division). This local interpolation method combines the advantages of a pure pixel read-out (high local and global rate capability) with those of a projecting read-out (small number of channels). The current prototype system has an active area of 28 x 28mm(2) with effectively 140 x140 pixels. Various test measurements at synchrotron light sources with biological samples have been performed demonstrating the good spatial resolution (around 300 mu m FWHM), the high intensity precision (only Poisson limited) and the high rate capability (exceeding 1 MHz spot rate). Moreover, time resolved measurements in the microsecond domain have been performed, and fine angular slicing has been applied to protein crystallography experiments. The detector has a high reliability and robustness, particularly when compared to conventional gaseous detectors, and the extension of the technology used to larger active areas is feasible.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 21 条
  • [1] First performance assessment of the small-angle X-ray scattering beamline at ELETTRA
    Amenitsch, H
    Rappolt, M
    Kriechbaum, M
    Mio, H
    Laggner, P
    Bernstorff, S
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 506 - 508
  • [2] Arndt U. W., 1990, SYNCHROTRON RAD NEWS, V3, P17
  • [3] High-throughput asymmetric double-crystal monochromator of the SAXS beamline at ELETTRA
    Bernstorff, S
    Amenitsch, H
    Laggner, P
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1215 - 1221
  • [4] An interpolating 2D pixel readout structure for synchrotron X-ray diffraction in protein crystallography
    Besch, HJ
    Junk, M
    Meissner, W
    Sarvestani, A
    Stiehler, R
    Walenta, AH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) : 244 - 248
  • [5] BRESSAN A, 1998, UNPUB NUCL INSTR MET
  • [6] A prototype 8x8 pixel array X-ray detector for protein crystallography
    Datte, P
    Beuville, E
    Beche, JF
    Cork, C
    Earnest, T
    Millaud, J
    Nygren, D
    Padmore, H
    Turko, B
    Xuong, NH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (03) : 471 - 480
  • [7] A pixel-array detector for time-resolved X-ray diffraction
    Eikenberry, EF
    Barna, SL
    Tate, MW
    Rossi, G
    Wixted, RL
    Sellin, PJ
    Gruner, SM
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 252 - 255
  • [8] POSITION-SENSITIVE X-RAY DETECTOR
    GABRIEL, A
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (10) : 1303 - 1305
  • [9] TOWARDS THE MEASUREMENT OF IDEAL DATA FOR MACROMOLECULAR CRYSTALLOGRAPHY USING SYNCHROTRON SOURCES
    HELLIWELL, JR
    EALICK, S
    DOING, P
    IRVING, T
    SZEBENYI, M
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 1993, 49 : 120 - 128
  • [10] The ''RAPID'' high rate large area X-ray detector system
    Lewis, RA
    Helsby, WI
    Jones, AO
    Hall, CJ
    Parker, B
    Sheldon, J
    Clifford, P
    Hillen, M
    Sumner, I
    Fore, NS
    Jones, RWM
    Roberts, KM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) : 32 - 41