Experimental investigation of two-phase thermosyphon loop for passive containment cooling

被引:13
作者
Yin, Xuan [1 ]
Hu, Jian [2 ]
Chi, Xiangyu [1 ]
Li, Yaru [1 ]
Nan, Zezhao [1 ]
Wang, Naihua [1 ]
机构
[1] Shandong Univ, Inst Thermal Sci & Technol, Jinan 250061, Shandong, Peoples R China
[2] State Key Lab Nucl Power Safety Monitoring Techno, Shenzhen, Peoples R China
关键词
Two-phase thermosyphon loop; Heat transfer; Thermal resistance; Water; BOILING HEAT-TRANSFER; VERTICAL TUBE; PIPE; FLOW; CONDENSATION; SYSTEM; MODEL;
D O I
10.1016/j.applthermaleng.2020.116403
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article investigates the operating characteristics of a two-phase thermosyphon loop in a pressure vessel to simulate the operating state of the thermosyphon loop in a passive containment cooling system. In this study, water is used as the working fluid, and the filling ratio ranges from 40% to 65%. The condenser is placed in a boiling water tank at 100 degrees C. The evaporator is placed in a pressure vessel, and the experimental range of pressure in the vessel is 0.32-0.46 MPa. The effects of the filling ratio and vessel pressure on the circulation loop and evaporator are analyzed, and the thermal resistance is calculated to characterize the heat transfer performance. The results show that the driven temperature difference and the length of the two-phase fluid region in the evaporator tube determine the heat transfer capacity of the thermosyphon loop. As the vessel pressure increased, a high filling ratio resulted in better heat transfer. However, the higher the filling ratio, the higher the pressure required for circulation, and the greater the pressure loss along the circulation path. The convective heat transfer and nucleate boiling heat transfer occur simultaneously in the evaporator at low heat flux.
引用
收藏
页数:11
相关论文
共 32 条
[1]   Heat transfer characteristics of a natural circulation separate heat pipe under various operating conditions [J].
Bai, Ye ;
Wang, Liang ;
Zhang, Shuang ;
Xie, Ningning ;
Chen, Haisheng .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 :191-200
[2]   Research on the refrigerant column height in the downcomer of a two-phase loop thermosyphon [J].
Cao, Hanwen ;
Ding, Tao ;
He, Zhiguang ;
Li, Zhen .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 94 :40-48
[3]   Sub-atmospheric boiling heat transfer and thermal performance of two-phase loop thermosyphon [J].
Chang, S. W. ;
Lo, D. C. ;
Chiang, K. F. ;
Lin, C. Y. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 39 :134-147
[4]  
Coleman H. W., 2009, Experimentation, Validation, and Uncertainty Analysis for Engineers
[5]   Experiment research on influence factors of the separated heat pipe system, especially the filling ratio and Freon types [J].
Ding, Tao ;
Cao, Han Wen ;
He, Zhi Guang ;
Li, Zhen .
APPLIED THERMAL ENGINEERING, 2017, 118 :357-364
[6]   Improvement of the subcooled boiling model for low-pressure conditions in thermal-hydraulic codes [J].
Hari, S ;
Hassan, YA .
NUCLEAR ENGINEERING AND DESIGN, 2002, 216 (1-3) :139-152
[7]   CRITICAL HEAT-FLUX IN A CLOSED 2-PHASE THERMOSYPHON [J].
IMURA, H ;
SASAGUCHI, K ;
KOZAI, H ;
NUMATA, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (08) :1181-1188
[8]   Two-phase closed thermosyphons: A review of studies and solar applications [J].
Jafari, Davoud ;
Franco, Alessandro ;
Filippeschi, Sauro ;
Di Marco, Paolo .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 53 :575-593
[9]   Parametric experiments and CFD analysis on condensation heat transfer performance of externally condensing tubes [J].
Jeon, Byong Guk ;
Kim, Do Yun ;
Shin, Chang Wook ;
No, Hee Cheon .
NUCLEAR ENGINEERING AND DESIGN, 2015, 293 :447-457
[10]  
Junior AA.M., 2019, ENERGY CONVERS MANAG, V202