Current approaches for the fitting and refinement of atomic models into cryo-EM maps using CCP-EM

被引:80
|
作者
Nicholls, Robert A. [1 ]
Tykac, Michal [1 ]
Kovalevskiy, Oleg [1 ]
Murshudov, Garib N. [1 ]
机构
[1] MRC Lab Mol Biol, Struct Studies, Francis Crick Ave, Cambridge CB2 0QH, England
基金
英国生物技术与生命科学研究理事会; 英国医学研究理事会;
关键词
REFMAC5; cryo-EM; model refinement; map blurring; map sharpening; Divide and Conquer; ProSHADE; symmetry detection; LOW-RESOLUTION REFINEMENT; CRYOELECTRON MICROSCOPY; RESTRAINTS; REFMAC5; TOOLS; DNA;
D O I
10.1107/S2059798318007313
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent advances in instrumentation and software have resulted in cryo-EM rapidly becoming the method of choice for structural biologists, especially for those studying the three-dimensional structures of very large macromolecular complexes. In this contribution, the tools available for macromolecular structure refinement into cryo-EM reconstructions that are available via CCP-EM are reviewed, specifically focusing on REFMAC5 and related tools. Whilst originally designed with a view to refinement against X-ray diffraction data, some of these tools have been able to be repurposed for cryo-EM owing to the same principles being applicable to refinement against cryo-EM maps. Since both techniques are used to elucidate macromolecular structures, tools encapsulating prior knowledge about macromolecules can easily be transferred. However, there are some significant qualitative differences that must be acknowledged and accounted for; relevant differences between these techniques are highlighted. The importance of phases is considered and the potential utility of replacing inaccurate amplitudes with their expectations is justified. More pragmatically, an upper bound on the correlation between observed and calculated Fourier coefficients, expressed in terms of the Fourier shell correlation between half-maps, is demonstrated. The importance of selecting appropriate levels of map blurring/sharpening is emphasized, which may be facilitated by considering the behaviour of the average map amplitude at different resolutions, as well as the utility of simultaneously viewing multiple blurred/sharpened maps. Features that are important for the purposes of computational efficiency are discussed, notably the Divide and Conquer pipeline for the parallel refinement of large macromolecular complexes. Techniques that have recently been developed or improved in Coot to facilitate and expedite the building, fitting and refinement of atomic models into cryo-EM maps are summarized. Finally, a tool for symmetry identification from a given map or coordinate set, ProSHADE, which can identify the point group of a map and thus may be used during deposition as well as during molecular visualization, is introduced.
引用
收藏
页码:492 / 505
页数:14
相关论文
共 50 条
  • [1] Current approaches for automated model building into cryo-EM maps using Buccaneer with CCP-EM
    Hoh, Soon Wen
    Burnley, Tom
    Cowtan, Kevin
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2020, 76 : 531 - 541
  • [2] Fitting, refinement and validation of atomic models in cryo-EM maps using TEMPy2
    Topf, D. M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2022, 78 : E20 - E20
  • [3] Refinement of Atomic Structures Against cryo-EM Maps
    Murshudov, G. N.
    RESOLUTION REVOLUTION: RECENT ADVANCES IN CRYOEM, 2016, 579 : 277 - 305
  • [4] Flexible Fitting of Atomic Models into Cryo-EM Density Maps Guided by Helix Correspondences
    Dou, Hang
    Burrows, Derek W.
    Baker, Matthew L.
    Jul, Tao
    BIOPHYSICAL JOURNAL, 2017, 112 (12) : 2479 - 2493
  • [5] Flexible fitting of atomic structures into cryo-EM maps using constrained geometric simulations
    Jolley, Craig C.
    Wells, Stephen A.
    Fromme, Petra
    Thorpe, Michael F.
    BIOPHYSICAL JOURNAL, 2007, : 508A - 508A
  • [6] Damped Dynamics as a Validation Platform for the Flexible Refinement of Atomic Models Against Cryo-EM Maps
    Wriggers, Willy R.
    Galkin, Vitold E.
    Hunter, Wade A.
    Kovacs, Julio A.
    BIOPHYSICAL JOURNAL, 2020, 118 (03) : 292A - 292A
  • [7] Automated atomic modeling in cryo-EM maps
    Singh, Arunima
    NATURE METHODS, 2024, 21 (05) : 749 - 749
  • [8] New tools for the analysis and validation of cryo-EM maps and atomic models
    Afonine, Pavel V.
    Klaholz, Bruno P.
    Moriarty, Nigel W.
    Poon, Billy K.
    Sobolev, Oleg V.
    Terwilliger, Thomas C.
    Adams, Paul D.
    Urzhumtsev, Alexandre
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2018, 74 : 814 - 840
  • [9] Automatic Building of Protein Atomic Models from Cryo-EM Maps
    Bouvier, Guillaume
    Bardiaux, Benjamin
    Nilges, Michael
    BIOPHYSICAL JOURNAL, 2018, 114 (03) : 190A - 191A
  • [10] Bayesian cryo-EM Refinement
    Blau, Christian
    Bock, Lars
    Kutzner, Carsten
    Vaiana, Andrea
    Grubmuller, Helmut
    BIOPHYSICAL JOURNAL, 2015, 108 (02) : 470A - 470A