Sensitive detection of near-infrared fluorescent dyes using high-performance liquid chromatography with peroxyoxalate chemiluminescence detection system

被引:0
|
作者
Kimoto, K [1 ]
Gohda, R [1 ]
Murayama, K [1 ]
Santa, T [1 ]
Fukushima, T [1 ]
Homma, H [1 ]
Imai, K [1 ]
机构
[1] UNIV TOKYO,FAC PHARMACEUT SCI,BUNKYO KU,TOKYO 113,JAPAN
关键词
D O I
10.1002/(SICI)1099-0801(199607)10:4<189::AID-BMC585>3.0.CO;2-P
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The highly sensitive detection of four near-infrared (near-IR) fluorescent dyes, methylene blue, pyridine 1, oxazine 1 and 3,3'-diethylthiadicarbocyanine iodide (DTDCI) by high-performance liquid chromatography (HPLC) with post-column peroxyoxalate chemiluminescence (PO-CL) detection utilizing bis(4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl) oxalate (TDPO) and hydrogen peroxide was examined, The detection limits for methylene blue, pyridine 1, oxazine 1 and DTDCI were 120, 27, 31, 0.19 fmol on-column at a signal-to-noise ratio of 2, respectively, The sensitivity for DTDCI was 250 times that obtained by HPLC with the conventional fluorescent detection.
引用
收藏
页码:189 / 190
页数:2
相关论文
共 50 条
  • [31] A model for mechanism of peroxyoxalate chemiluminescence as applied to detection in liquid chromatography
    Orosz, G
    Givens, RS
    Schowen, RL
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1996, 26 (01) : 1 - 27
  • [32] High-performance liquid chromatography with chemiluminescence detection of disopyramide in human serum
    Chiba, R
    Yamamoto, N
    Tanaka, A
    ANALYTICAL SCIENCES, 1998, 14 (06) : 1153 - 1155
  • [33] Application of chemiluminescence for the detection of peroxy compounds in high-performance liquid chromatography
    Stefan Baj
    Anna Chrobok
    Mariola Cieślik
    Tomasz Krawczyk
    Analytical and Bioanalytical Chemistry, 2003, 375 : 327 - 330
  • [34] Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection
    Cui, H
    He, CX
    Zhao, GW
    JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) : 171 - 179
  • [35] Determination of atmospheric nitrobenzanthrones by high-performance liquid chromatography with chemiluminescence detection
    Tang, N
    Taga, R
    Hattori, T
    Tamura, K
    Toroba, A
    Kizu, R
    Hayakawa, K
    ANALYTICAL SCIENCES, 2004, 20 (01) : 119 - 123
  • [36] PHOTOCATALYTIC CHEMILUMINESCENCE DETECTION OF QUINONES IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    POULSEN, JR
    BIRKS, JW
    ANALYTICAL CHEMISTRY, 1990, 62 (13) : 1242 - 1251
  • [37] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR CATECHOLAMINE ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    KAWASAKI, T
    WONG, O
    IMAI, K
    KUWANA, T
    HIGUCHI, T
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1987, 76 (11) : S6 - S6
  • [38] Application of chemiluminescence for the detection of peroxy compounds in high-performance liquid chromatography
    Baj, S
    Chrobok, A
    Cieslik, M
    Krawczyk, T
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (02) : 327 - 330
  • [39] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION OF DERIVATIZED MICROCYSTINS
    MURATA, H
    SHOJI, H
    OSHIKATA, M
    HARADA, KI
    SUZUKI, M
    KONDO, F
    GOTO, H
    JOURNAL OF CHROMATOGRAPHY A, 1995, 693 (02) : 263 - 270
  • [40] Determination of Atmospheric Nitrobenzanthrones by High-Performance Liquid Chromatography with Chemiluminescence Detection
    Ning Tang
    Rina Taga
    Tetsuyuki Hattori
    Kenji Tamura
    Akira Toroba
    Ryoichi Kizu
    Kazuichi Hayakawa
    Analytical Sciences, 2004, 20 : 119 - 123